No Image Found   

Check List Report

Madhupur Nagar Parishad

Version Number: 1.0.70  
Version Date: 16/10/2020 
Report Generated On: 15-07-2024 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictDEOGHAR
AuthorityMADHUPUR NAGAR PARISHAD
Inward_NoMNP/BP/0013/W03/2024/ALT2
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentAddition or Alteration
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageHarlatand
Taluka18
Layout Sanction Date10/6/2024
Architect Details
Architect NamePRAWEEN KUMAR MAHTO
License No.MNP/ENG/0005/2020
Architect AddressS/O KARTIK MAHTO, BENDI, CHATROCHATTI,JHARKHAND 825315
Architect EmailIDPKPMAHTO25@GMAIL.COM
Architect Mobile No9973737154
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No6
NorthPlot No. - LAND OF KRISHNA LAL MARODIA
SouthPlot No. - LAND OF KRISHNA LAL MARODIA
EastRoad Width - 18.2
WestPlot No. - LAND OF KRISHNA LAL MARODIA
Owner's Details
NameSHAHNEWAZ KHAN
AddressMADHUPUR
Email IDSHAHEWAZ434@GMAIL.COM
Mobile No8210768497
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 313.75
2 Plot area as per Document by Applicant 313.75
3 Physical area measured at site 313.73
4 Area as per Site Visit (Site Visit Report) 313.73
5Area as per Drawing 313.73

Area of Plot Considered : 313.73

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 313.73
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 313.73
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 275.12
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 38.61
38.61
Balance Plot Area 275.12

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 188.24
Proposed Coverage Area ( 60.00 % ) 188.23
Total Prop. Coverage Area ( 60 % ) 188.23
Balance coverage area ( - % ) 0.01
FAR CHECK
Perm. FAR Area ( 2.000 ) 627.46
Total Perm. FAR area 627.46
Residential FAR 564.69
Proposed FAR Area 564.69
Total Proposed FAR Area 564.69
Consumed FAR (Factor) 1.80
Balance FAR Area 62.77
BUA CHECK
Total Proposed BuiltUp Area 564.69


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 18.2 18.20
Proposed Road Width as per Master Plan 18.2 -
Road Widening Width 0 -
Plot size (as per measurement) 313.73 313.73
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 313.73 OK
Plot Width Mt. - - 8.54 OK
Plot Depth Mt. - - 36.74 OK
Access Width Mt. - - 18.20 OK
Plot Frontage Mt. - - 8.54 OK
Coverage Area Sq.Mt. - 188.24 188.23 OK
FAR Area Sq.Mt. - 627.46 564.69 OK
Consumed FAR Sq.Mt. - 2.00 1.80 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 15.69 38.61 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 38.61 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 2.71 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 10 OK
A-1 (1) Front Margin... 18.2 M WIDE ROAD Mt. 4.00 - 4.30 OK
Rear Margin Mt. 3.00 - 3.05 OK
Side1 Margin Mt. 1.00 - 1.07 OK
Side2 Margin Mt. 1.00 - 1.07 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (1) Height Mt. 30.00 9.61 OK
A (1) Second Floor - Height Mt. 2.75 - 3.20 OK
Second Floor - Clear Height Mt. 2.75 - 3.10 OK
Second Floor - Beam Clear Height Mt. 2.40 - 3.06 OK
First Floor - Height Mt. 2.75 - 3.20 OK
First Floor - Clear Height Mt. 2.75 - 3.10 OK
First Floor - Beam Clear Height Mt. 2.40 - 3.06 OK
Ground Floor - Height Mt. 2.75 - 3.20 OK
Ground Floor - Clear Height Mt. 2.75 - 3.10 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 3.06 OK
A (1) Terrace Floor - Height Mt. - - 1.07 OK
Terrace Floor - Clear Height Mt. - - 1.07 OK
Terrace Floor - Beam Clear Height Mt. - - 1.07 OK
A (1) No. of Floors No. - 3 OK
No. of Tenements No. - 1 OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.220 OK
STAIRCASE - Tread Width Mt. - 0.254 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.592 OK
SECOND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.220 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.152 OK
STAIRCASE - Riser No. On Flight No. - 8 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.220 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.152 OK
STAIRCASE - Riser No. On Flight No. - 8 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
SUMP TANK Area Sq.Mt. - - 2.86 OK
Width Mt. - - 1.50 OK
Depth Mt. - - 1.91 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 2.49 OK
Width Mt. - - 1.26 OK
Depth Mt. - - 1.97 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.26 OK
Width Mt. - - 0.17 OK
Depth Mt. - - 1.55 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 5.94 OK
Width Mt. - - 1.74 OK
Depth Mt. - - 3.42 OK
Height Mt. - - - OK
A (1) Rain Water Harvesting - No No. 1 - 1 OK
Solar Water Heating System - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Madhupur Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Madhupur Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For narrow plots,the setbacks on sides may be compensated in front and rear setbacks so as to ensure that the overall aggregate setbacks are maintained in the site, subject to maintaining a minimum of side setback of 1m in case of buildings of height up to 10.0 mt.
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
StairCase (1) No Rule Defined
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) For Individual residential buildings having more than 150 sq m. plinth area, Provisions of Solar Water Heating System shall be done Solar Water Heating System
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)
Bed Room3.58x3.10 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Hall4.80x21.82 No Rule Defined
Hall6.15x21.82 No Rule Defined
Toilet2.44x1.22 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}