No Image Found

Failed List Report

Pakur Nagar Parishad

Version Number: 1.0.31
Version Date: 30/06/2018
Report Generated On: 19-01-2019

[-] Collapse All


General Details
Region JHARKHAND URBAN LOCAL BODIES
District PAKUR
Authority PAKUR NAGAR PARISHAD
Inward_No PNPC/BP/0023/W10/2018
Application Type General Proposal
Project Type Building Permission
Nature of Development New
Location of Development Area Old Area
City Area/TPScheme No NA
Village Pakur
Taluka 28
Architect Details
Architect Name SHYAM DUTT SHUKLA
License No. PNPC/ENG/0004/2017
Architect Address BIRSA CHOWK
Architect EmailID SHYAMDUTTSHUKLA@GMAIL.COM
Architect Mobile No 7759029119
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No 491
North Plot No. - PRIVATE
South Road Width - 3.05
East Plot No. - PRIVATE
West Plot No. - PRIVATE
Owner's Details
Name AFSANA PARVIN
Address W/O TAUFIK ANSARI, JABARDAHA, HIRANPUR, PAKUR
Email ID TAUFIKANSARI507@GMAIL.COM
Mobile No 9470101862
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 201.65
2 Plot area as per Document by Applicant 201.65
3 Physical area measured at site 201.65
4 Area as per Site Visit (Site Visit Report) 201.65
5 Area as per Drawing 201.65

Area of Plot Considered : 201.65

[-] Table 2b
Proposal Detail :
Unit Meters
Development Detail :
Plot PLOT
Plot Occupancy Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building Structure Non-Highrise
Building Type Single Detached House
Gross Plot Area 201.65
Deduction from Gross Plot area
- Surrender Free of Cost 12.41
12.41
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 189.24
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 166.46
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 12.41
- Common Plot 22.78
35.19
Balance Plot Area 166.46

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 132.47
Proposed Coverage Area ( 61.80 % ) 116.95
Total Prop. Coverage Area ( 61.8 % ) 116.95
Balance coverage area ( 8.20 % ) 15.52
FAR CHECK
Perm. FAR Area ( 1.20 ) 241.98
Total Perm. FAR area 241.98
Residential FAR 116.95
Proposed FAR Area 116.95
Total Proposed FAR Area 116.95
Consumed FAR (Factor) 0.58
Balance FAR Area 125.03
BUA CHECK
Total Proposed BuiltUp Area 116.95


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 3.05 3.05
Proposed Road Width as per Master Plan 3.05 -
Road Widening Width 1e-14 1.05
Plot size (as per measurement) 201.65 201.65





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth less than 3.60 mt., the Floor Area Ratio-FAR shall be 1.2 {As per Rule No.39, Table 15, Note i}
(2) For Pakur Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth less than 3.60 mt., the Floor Area Ratio-FAR shall be 1.2 {As per Rule No.39, Table 15, Note i}
(2) For Pakur Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 15-21 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.5 mt., Rear 1.5 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Exceeding 50 mt. and upto 100 mt. shall be 5.1 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 50 mt. and upto 100 mt. shall be 5.1 mt. {As per Rule No. 34 Table No. 6}
Building Level
Building Height For Row house, Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 8.55 mt. {As per Chapter VII}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width upto 3.6 mt. only G+1 floors shall be allowed {As per Rule No. 39.1 Note 1}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) -
(6) No need to check distance from Building SOLAR HEATING SYSTEM
Building Level (Rooms)