General Details
Region JHARKHAND URBAN LOCAL BODIES
District PAKUR
Authority PAKUR NAGAR PARISHAD
Inward_No PNPC/BP/0022/W16/2018
Application Type General Proposal
Project Type Building Permission
Nature of Development New
Location of Development Area Old Area
City Area/TPScheme No NA
Village Pakur
Taluka 28
Architect Details
Architect Name SHYAM DUTT SHUKLA
License No. PNPC/ENG/0004/2017
Architect Address BIRSA CHOWK
Architect EmailID SHYAMDUTTSHUKLA@GMAIL.COM
Architect Mobile No 7759029119
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No 186/919
North Plot No. - PRIVATE
South Road Width - 24.40
East Plot No. - PRIVATE
West Plot No. - PRIVATE
Owner's Details
Name MD. NIAJUDDIN BISWAS, ZIAUL HAQUE
Address NAWADA, HARIHARA
Email ID ZIAULPAKUR12@GMAIL.COM
Mobile No 9749734787
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 707.97
2 Plot area as per Document by Applicant 707.97
3 Physical area measured at site 707.97
4 Area as per Site Visit (Site Visit Report) 707.97
5 Area as per Drawing 707.97

Area of Plot Considered : 707.97

[-] Table 2b
Proposal Detail :
Unit Meters
Development Detail :
Plot PLOT
Plot Occupancy Residential
Plot SubUse Residential Bldg/Apartment
Building Structure Non-Highrise
Building Type Single Detached House
Gross Plot Area 707.97
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 707.97
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 624.11
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 83.86
83.86
Balance Plot Area 624.11

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 424.78
Proposed Coverage Area ( 19.48 % ) 137.93
Total Prop. Coverage Area ( 19.48 % ) 137.93
Balance coverage area ( 40.52 % ) 286.85
FAR CHECK
Perm. FAR Area ( 2.00 ) 1415.94
Total Perm. FAR area 1415.94
Residential FAR 137.93
Proposed FAR Area 137.93
Total Proposed FAR Area 137.93
Consumed FAR (Factor) 0.19
Balance FAR Area 1278.01
BUA CHECK
Total Proposed BuiltUp Area 137.93


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 24.4 24.40
Proposed Road Width as per Master Plan 24.4 -
Road Widening Width 1e-13 -
Plot size (as per measurement) 707.97 707.97


Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 707.97 OK
Plot Width Sq.Mt. - - 18.37 OK
Plot Depth Sq.Mt. - - 38.53 OK
Access Width Sq.Mt. - - 24.40 OK
Plot Frontage Sq.Mt. - - 17.98 OK
Coverage Area Sq.Mt. - 424.78 137.93 OK
FAR Area Sq.Mt. - 1415.94 137.93 OK
Consumed FAR Sq.Mt. - 2.00 0.19 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 70.80 83.86 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 83.86 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 6.75 OK
Tree Cover (Plantation) - Angle Degree - 76.38 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 13 OK
A-1 (MD NIAJUDDIN BISWAS MD ZIAUL HAQUE) Front Margin... 24.40 MTR WIDE MAIN ROAD Access Road Mt. 4.00 - 4.50 OK
Rear Margin Mt. 3.00 - 19.86 OK
Side1 Margin Mt. 1.00 - 3.83 OK
Side2 Margin Mt. 1.00 - 3.67 OK

Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (MD NIAJUDDIN BISWAS MD ZIAUL HAQUE) Height Mt. 41.10 3.05 OK
A (MD NIAJUDDIN BISWAS MD ZIAUL HAQUE) Ground Floor - Height Mt. 2.75 - 3.05 OK
Plinth - Height Mt. 0.45 - 0.61 OK
A (MD NIAJUDDIN BISWAS MD ZIAUL HAQUE) Terrace Floor - Height Mt. 1.00 1.20 1.07 OK
A (MD NIAJUDDIN BISWAS MD ZIAUL HAQUE) No. of Floors No. - 1 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.156 OK
STAIRCASE - Tread Width Mt. 0.225 0.267 OK
STAIRCASE - Riser Height Mt. 0.200 0.152 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.156 OK
STAIRCASE - Tread Width Mt. - 0.267 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. 2.100 - 2.591 OK
Sewage Treatment Plant Area Sq.Mt. - - 0.94 OK
Width Mt. - - 0.88 OK
Depth Mt. - - 1.07 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 7.03 OK
Width Mt. - - 2.42 OK
Depth Mt. - - 2.91 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 3.51 OK
Width Mt. - - 0.63 OK
Depth Mt. - - 5.57 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 5.56 OK
Width Mt. - - 1.92 OK
Depth Mt. - - 2.90 OK
Height Mt. - - - OK
A (MD NIAJUDDIN BISWAS MD ZIAUL HAQUE) Rain Water Harvesting - No No. 1 - 1 OK
All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Pakur Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Pakur Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 33-39 mt. and Plot width 15-21 mt., Margin required in Front shall be 4.0 mt., Rear 3.0 mt. and 1.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width above 18.30 mt., No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 18.30 mt. and above, No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
Building Level (Rooms)