-
No Image Found   

Failed List Report

Pakur Nagar Parishad

Version Number: 1.0.59  
Version Date: 16/10/2020 
Report Generated On: 05-08-2021 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictPAKUR
AuthorityPAKUR NAGAR PARISHAD
Inward_NoPNPC/BP/0007/W04/2021
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageBaliharpur
Taluka28
Architect Details
Architect NameSamsuddin Ansari
License No.PNPC/SUP/0003/2017
Architect AddressVill- Kamalghati, Post- Hiranpur, Dist-Pakur
Architect EmailIDsamsuddinansaripkr@gmail.com
Architect Mobile No9006553778
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No1321
NorthPlot No. - PLOT OF AJEET
SouthPlot No. - OWNER S PLOT
EastPlot No. - PLOT NO- 1320
WestRoad Width - 4.57 MTR WIDE MAIN ROAD
Owner's Details
NameMADHUMATI GHOSH
AddressBALIHARPUR, PAKUR
Email IDkansari085@gmail.com
Mobile No8950302246
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 66.85
2 Plot area as per Document by Applicant 66.85
3 Physical area measured at site 66.85
4 Area as per Site Visit (Site Visit Report) 167.48
5Area as per Drawing 65.39

Area of Plot Considered : 65.39

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
Plotplot
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 65.39
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 65.39
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 59.79
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 5.60
5.60
Balance Plot Area 59.79

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 45.77
Proposed Coverage Area ( 59.57 % ) 38.95
Total Prop. Coverage Area ( 59.57 % ) 38.95
Balance coverage area ( 10.43 % ) 6.82
FAR CHECK
Perm. FAR Area ( 1.20 ) 78.47
Total Perm. FAR area 78.47
Residential FAR 77.90
Proposed FAR Area 77.90
Total Proposed FAR Area 77.90
Consumed FAR (Factor) 1.19
Balance FAR Area 0.57
BUA CHECK
Total Proposed BuiltUp Area 77.90


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 3 3.00
Proposed Road Width as per Master Plan 3 -
Road Widening Width 1e-10 -
Plot size (as per measurement) 167.48 65.39
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land 100.63 0.00 Failed

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area 100.63 - 0.00 Failed

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
GHOSH-1 (MADHUMATI) ResvRoad Width Check for... 3.0M MAIN ROAD Access Road Mt. 0.30 0.00 Failed

     Building Miscellanies Details
No Rule Status
1 WINDOW should not intersect/outside the Plot at Ground Floor Plan in GHOSH (MADHUMATI) Building. Failed
2 FAR should not intersect/outside the Plot at Ground Floor Plan in GHOSH (MADHUMATI) Building. Failed
3 FAR should not intersect/outside the Plot at First Floor Plan in GHOSH (MADHUMATI) Building. Failed

   
   

[-] Building:GHOSH (MADHUMATI)


[-] Floor:GROUND FLOOR PLAN

[-] Misc Checks (Table 9a)
Tnmt No. Room Name Area Width Depth Ventilation Status
Reqd Prop Reqd Prop Reqd Prop Reqd Prop
SPLIT A LIVING/DINING 2.32X3.56 9.50 8.24 2.40 2.32 2.40 3.56 0.82 3.15 Failed
KITCHEN 1.44X3.28 5.00 4.98 1.80 1.60 1.80 3.28 0.50 1.08 Failed

[-] Floor:FIRST FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.


   



[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth less than 3.60 mt., the Floor Area Ratio-FAR shall be 1.2 {As per Rule No.39, Table 15, Note i}
(2) For Pakur Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth less than 3.60 mt., the Floor Area Ratio-FAR shall be 1.2 {As per Rule No.39, Table 15, Note i}
(2) For Pakur Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 10-15 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.0 mt., Rear 1.5 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road upto 50 mt. shall be 3.6 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road upto 50 mt. shall be 3.6 mt. {As per Rule No. 34 Table No. 6}
Building Level
Building Height For old area location, on Road width upto 3.6 mt.,Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 7.0 mt. {As per Rule No. 39.1 Note 1}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width upto 3.6 mt. only G+1 floors shall be allowed {As per Rule No. 39.1 Note 1}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) -
(4) No need to check distance from Building Sewage Treatment Plant
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
(7) No need to check distance from Building ENT.GATE
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)