No Image Found   

Failed List Report

Pakur Nagar Parishad

Version Number: 1.0.66  
Version Date: 16/10/2020 
Report Generated On: 08-09-2023 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictPAKUR
AuthorityPAKUR NAGAR PARISHAD
Inward_NoPNPC/BP/0022/W19/2023
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageBallavpur
Taluka28
Architect Details
Architect NameNavin Kumar Mandal
License No.PNPC/ENG/0004/2019
Architect AddressRajapara Pakur Jharkhand
Architect EmailIDkumarnavinlive@gmail.com
Architect Mobile No8709756328
Plot Details
Plot Use Commercial
Plot SubUse Shop
PlotNearbyReligiousStructure NA
Plot/SubPlot No339,341,341/939
NorthPlot No. - 339,341,341/939 PART
SouthRoad Width - 12.19
EastPlot No. - 339,341,341/939 PART
WestPlot No. - 339,341,341/939 PART
Owner's Details
NameSMT RITU OJHA
AddressBALLAVPUR PAKUR
Email IDSANJAYKISHOREOJHA@GMAIL.COM
Mobile No8809605144
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 797.54
2 Plot area as per Document by Applicant 797.54
3 Physical area measured at site 797.54
4 Area as per Site Visit (Site Visit Report) 797.54
5Area as per Drawing 797.54

Area of Plot Considered : 797.54

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyCommercial
Plot SubUse Shop
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 797.54
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 797.54
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 797.54

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 398.77
Proposed Coverage Area ( 34.95 % ) 278.71
Total Prop. Coverage Area ( 34.95 % ) 278.71
Balance coverage area ( 15.05 % ) 120.06
FAR CHECK
Perm. FAR Area ( 2.000 ) 1595.08
Total Perm. FAR area 1595.08
Commercial FAR 278.71
Proposed FAR Area 278.71
Total Proposed FAR Area 278.71
Consumed FAR (Factor) 0.35
Balance FAR Area 1316.37
BUA CHECK
Total Proposed BuiltUp Area 278.71


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 12.19 12.19
Proposed Road Width as per Master Plan 12.1 -
Road Widening Width 12.19 -
Plot size (as per measurement) 797.54 797.54
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
Common Plot Checks Common Plot - Total Area Sq.Mt. 39.88 0.00 Failed
Tree Tree - Nos Of Trees No. 4 0 Failed
Total Car In Area Sq.Mt. 12.50 - 0.00 Failed
Total TwoWheeler In Area Sq.Mt. 6.00 - 0.00 Failed

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (COMMERCIAL) Rain Water Harvesting - No No. 1 - 0 Failed
       



[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Pakur Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Pakur Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Commercial Building upto 16.4 mt. Ht. having Plot Depth 45 mt. or above and Plot width 15-21 mt., Margin required in Front shall be 8.0 mt., Rear 5.0 mt. and 2.5 mt. shall be provided on both side. {As per Rule No. 36 Table 10 & 11}
Building Level
Building Height For old area, on Road width 9.10-12.20 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 23.10 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 9.1-12.20 mt. only G+6 floors shall be allowed {As per Rule No. 39.1 Table 15}
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)