Detail Scrutiny Report

Bishrampur Nagar Panchayat

Version Number: 1.0.66  
Version Date: 16/10/2020 
Report Generated On: 03-07-2023 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictPALAMU
AuthorityBishrampur Nagar Panchayat
Inward_NoBRNPC/BP/0005/W08/2023
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageRahela
Taluka27
Architect Details
Architect NameReshan Ali
License No.BRNPC/ENG/0002/2023
Architect AddressH.K Palaza,Near H.K Petrol Pump,Kuchhari Road,Garhwa,Jharkhand
Architect EmailIDreshan.ali.30@gmail.com
Architect Mobile No7991163526
Plot Details
Plot Use Mixed
Plot SubUse Resi+Comm
PlotNearbyReligiousStructure NA
Plot/SubPlot No187
NorthPlot No. - SUNIL KUMAR SHARMA
SouthPlot No. - RAJENDRA PRASAD
EastPlot No. - SHAMSHUDDIN KHAN,KABRISTAN
WestRoad Width - 7.0
Owner's Details
NameSHRI RAM NATH PRASAD KASHYAP
AddressDANDILA KALA,REHALA,PO+PS-REHALA,DIST-PALAMAU,JHARKHAND
Email IDreshan.ali.30@gmail.com
Mobile No9431147913
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 211.32
2 Plot area as per Document by Applicant 211.32
3 Physical area measured at site 211.32
4 Area as per Site Visit (Site Visit Report) 211.32
5Area as per Drawing 211.32

Area of Plot Considered : 211.32

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyMixed
Plot SubUse -
Higher Plot Use
Higher Plot Sub UseResi+Comm
Lower Plot Use
Lower Plot Sub Use
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 211.32
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 211.32
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 176.01
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 35.30
35.30
Balance Plot Area 176.01

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 147.92
Proposed Coverage Area ( 32.50 % ) 68.67
Total Prop. Coverage Area ( 32.5 % ) 68.67
Balance coverage area ( 37.50 % ) 79.25
FAR CHECK
Perm. FAR Area ( 2.500 ) 528.30
Total Perm. FAR area 528.30
Residential FAR 82.67
Commercial FAR 151.33
Proposed FAR Area 234.00
Total Proposed FAR Area 234.00
Consumed FAR (Factor) 1.11
Balance FAR Area 294.30
BUA CHECK
Total Proposed BuiltUp Area 234.01


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 7 7.00
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 211.32 211.32
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 21.13 35.30 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 35.30 0.00 0.00 - 1.13 - 90.00 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 24 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (BUILDING) Commercial ResiComm Bldg Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (BUILDING) 16.40 8.88 9.00 8.88 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (BUILDING) Second Floor 2.75 - 3.00 2.75 - 2.88 2.40 - 2.75 OK
First Floor 2.75 - 3.00 2.75 - 2.88 2.40 - 2.75 OK
Ground Floor 2.75 - 3.00 2.75 - 2.88 2.40 - 2.75 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (BUILDING) Terrace Floor - - 1.00 - - 1.00 - - 1.00 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (BUILDING) G + 4 3 - 3 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
147.92 68.67 OK
70% 32.5%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (BUILDING) - 68.67
  Total Prop. Coverage Area - 68.67
  Total Coverage Area 147.92 68.67

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi. Commercial
A (BUILDING) 1 234.01 82.67 151.33 234.01 234.01 03
Grand Total : 1 234.01 82.67 151.33 234.01 234.01 03


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (BUILDING)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 68.67 68.67 68.67 68.67
First Floor 82.67 82.67 82.67 82.67
Second Floor 82.67 82.67 82.67 82.67
Terrace Floor 0.00 0.00 0.00 0.00
Total : 234.01 234.01 234.01 234.01


[-] UnitBUA Table for Building :A (BUILDING)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR UNIT-1 SHOP 68.67 61.42 1 1
FIRST FLOOR UNIT-2 SHOP 82.67 74.17 1 1
SECOND FLOOR UNIT-3 FLAT 82.67 71.17 8 1
Total: - - 234.01 206.76 10 3


[-] Building :A (BUILDING)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi. Commercial
Ground Floor 68.67 0.00 68.67 68.67 68.67 01
First Floor 82.67 0.00 82.67 82.67 82.67 01
Second Floor 82.67 82.67 0.00 82.67 82.67 01
Terrace Floor 0.00 0.00 0.00 0.00 0.00 00
Total : 234.01 82.67 151.33 234.01 234.01 03
Total Number of Same Buildings : 1
Total : 234.01 82.67 151.33 234.01 234.01 03
[-] Table 4c-2

  FAR Area
Building FAR Area:234.00
Existing FAR Area :0.00
Perm.
528.30
Prop.
234.00
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (BUILDING) 7.0 M MAIN ROAD Access Road 7.50 15.00 4.50 4.50 1.00 1.00 1.00 1.00 OK






[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car Visitors Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (BUILDING) Commercial ResiComm Bldg > 0 200 135.90 1 1 - - - - - - -
> 0 200 135.90 - - - - - - 1 2 -
Residential Residential Bldg/Apartment > 0 1 1.00 1 1 - - - - - - -
> 0 1 1.00 - - - - - - 1 1 -
> 0 1 1.00 - - - 1 1 - - - -
Total : - - - - 2 2 - 1 1 - 3 5

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 2 25.00 OK
Total Car 2 25.00 2 25.00 OK
Visitor's Car Parking - - 1 12.50 OK
Total Visitor Parking 1 12.50 1 12.50 OK
TwoWheeler - - 5 10.00 OK
Total TwoWheeler 3 6.00 5 10.00 OK
Other Parking - - - 24.50 OK
Total 43.50 82.00 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

[-] Driveway Parking Checks (Table 7d)
Building/Plot Name Floor Name Driveway Name Width Status
Reqd Perm Prop
PLOT - DRIVEWAY 3.60 - 4.80 OK

   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (BUILDING)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR STAIRCASE 0.900 1.050 0.250 0.250 0.200 0.143 - 21 - - 0.000 OK
FIRST FLOOR STAIRCASE 0.900 1.050 0.250 0.250 0.200 0.158 - 19 - - 0.000 OK
SECOND FLOOR STAIRCASE 0.900 1.050 0.250 0.250 0.200 0.143 - 21 - - 0.000 OK
TERRACE FLOOR STAIRCASE - 1.050 - 0.250 - 0.000 - 0 - - 2.275 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SUMP TANK - - 0.94 - - 0.86 - - 1.10 - - 0.00 OK
RAIN WATER HARVESTING - - 1.21 - - 0.76 - - 1.59 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (BUILDING) Rain Water Harvesting 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (BUILDING)


[-] Floor:GROUND FLOOR



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:FIRST FLOOR



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:SECOND FLOOR



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 211.32 OK
  Plot Width - 4.80 OK
  Plot Depth - 44.02 OK
  Access Width - 7.00 OK
  Plot Frontage - 4.80 OK
  Coverage Area 147.92 68.67 OK
  FAR Area
Bldg. FAR Area : 234.00
Sanctioned FAR Area :0.00
528.30 234.00 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) No Rule Define.
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) No Rule Define.
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For narrow plots,the setbacks on sides may be compensated in front and rear setbacks so as to ensure that the overall aggregate setbacks are maintained in the site, subject to maintaining a minimum of side setback of 1m in case of buildings of height up to 10.0 mt.
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)