No Image Found

Detail Scrutiny Report

Bundu Nagar Panchayat

Version Number: 1.0.20
Version Date: 27/01/2018
Report Generated On: 07-02-2018

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictRANCHI
AuthorityBUNDU NAGAR PANCHAYAT
Inward_NoBNPC/BP/0005/W02/2017
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageBundu
Taluka14
Architect Details
Architect NameArun Ranjan
License No.BNPC/ARC/0002/2016
Architect Address303, Urmila Apartment, U B Lane Tharpakna
Architect EmailIDdotconsultant@gmail.com
Architect Mobile No9471550077
Plot Details
Plot Use Residential
Plot SubUse Boarding
PlotNearbyReligiousStructure NA
Plot/SubPlot No1920,1921,1922
NorthRoad Width - 3.53
SouthPlot No. - SURAJ MUNDA
EastPlot No. - BIRJU SONAR
WestPlot No. - GOPAL BHAGAT
Owner's Details
NameBHUTNATH BHAGAT
AddressBABURAM TOLI BUNDU RANCHI
Email IDarchitectdot@gmail.com
Mobile No9905746439
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 354.06
2 Plot area as per Document by Applicant 323.23
3 Physical area measured at site 323.23
4 Area as per Site Visit (Site Visit Report) 323.23
5Area as per Drawing 323.23

Area of Plot Considered : 323.23

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Boarding
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 323.23
Deduction from Gross Plot area
- Surrender Free of Cost 18.80
18.80
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 304.43
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 271.02
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 18.80
- Common Plot 33.41
52.21
Balance Plot Area 271.02

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 182.66
Proposed Coverage Area ( 60.07 % ) 182.87
Total Prop. Coverage Area ( 60.07 % ) 182.87
Balance coverage area ( - % ) 0.00
FAR CHECK
Perm. FAR Area ( 1.20 ) 387.88
Maximum Permissible FAR Area ( 2.00 ) 646.46
Total Perm. FAR area 646.46
Residential FAR 437.68
Proposed FAR Area 437.68
Total Proposed FAR Area 437.68
Consumed FAR (Factor) 1.35
Balance FAR Area 208.78
Total Paid Proposed FAR Area 49.80
BUA CHECK
Total Proposed BuiltUp Area 548.60


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 250 meter and upto 300 meter -
Existing Road Width 3.35 3.35
Proposed Road Width as per Master Plan 6.1 -
Road Widening Width 1.375 1.38
Plot size (as per measurement) 323.23 323.23




[-] Plot Level Checking (Table 3)

[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 15.22 33.41 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 33.41 0.00 0.00 - 1.99 - 86.01 No Access Provided OK




[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 4 OK





[-] Building Details (Table 4)

[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (RESIDENCE G2) Residential Residential Bldg/Apartment Non-Highrise



[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height (From GL) Height (From Street LVL) Status
A (RESIDENCE G2) 9.00 9.00 OK




[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Status
Reqd Perm Prop
A (RESIDENCE G2) Second Floor 2.75 - 3.00 OK
First Floor 2.75 - 3.00 OK
Ground Floor 2.75 - 3.00 OK
Plinth - - 0.45 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (RESIDENCE G2) Terrace Floor 1.00 1.20 1.00 OK


[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (RESIDENCE G2) P + 1 3 - 1 Failed


[-] Coverage Check (Table 4b)
Permissible Proposed Status
182.66 182.87 Failed
60% 60.07%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
A-1 (RESIDENCE G2) - 182.87
Total Prop. Coverage Area - 182.87
Total Coverage Area 182.66 182.87


[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Parking Resi.
A (RESIDENCE G2) 1 548.60 110.92 437.68 437.68 437.68 01
Grand Total : 1 548.60 110.92 437.68 437.68 437.68 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (RESIDENCE G2)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Maximum Permissible FAR Area (Sq.mt.) Total Paid Built Up Area (Sq.mt.)
Ground Floor 182.86 71.94 182.86 71.94 49.80 126.58
First Floor 182.87 182.87 182.87 182.87 0.00 0.00
Second Floor 182.87 182.87 182.87 182.87 0.00 0.00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00
Total : 548.60 437.68 548.60 437.68 49.80 126.58


[-] UnitBUA Table for Building :A (RESIDENCE G2) UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT A FLAT 437.68 392.67 8 1
TYPICAL - 1& 2 FLOOR PLAN SPLIT A FLAT 0.00 0.00 21 0
Total: - - 437.68 392.67 50 1


[-] Building :A (RESIDENCE G2)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Parking Resi.
Ground Floor 182.86 110.92 71.94 71.94 71.94 01
First Floor 182.87 0.00 182.87 182.87 182.87 00
Second Floor 182.87 0.00 182.87 182.87 182.87 00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 00
Total : 548.60 110.92 437.68 437.68 437.68 01
Total Number of Same Buildings : 1
Total : 548.60 110.92 437.68 437.68 437.68 01

[-] Table 4c-2

FARArea
Building FAR Area:437.68
Existing FAR Area :0.00
Perm.
646.46
Prop.
437.68
Status
OK





[-] Margin Checks (Table 5)
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (RESIDENCE G2) ROAD WIDENING AREA(SURRENDERED FREE OF COST) 3.00 3.54 1.80 1.80 0.90 0.90 0.90 1.05 OK







[-] Inner Building Details (Table 6)


No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.



[-] Parking Details (Table 7)


NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Residential Bldg/Apartment, In Building: A (RESIDENCE G2)



[-] Exemption Details (Table 8)



Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (RESIDENCE G2)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.900 1.025 0.250 0.250 0.200 0.150 - 10 - - 0.000 OK
TYPICAL - 1& 2 FLOOR PLAN STAIRCASE 0.900 1.025 0.250 0.250 0.200 0.150 - 10 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.025 - 0.250 - 0.000 - 0 - - 2.400 OK



[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SUMP TANK - - 5.40 - - 1.80 - - 3.00 - - 0.00 OK
RAIN WATER HARVESTING - - 4.00 - - 2.00 - - 2.00 - - 0.00 OK
ENT.GATE - - 0.90 - - 0.30 - - 3.00 - - 0.00 OK
SOLAR HEATING SYSTEM - - 2.25 - - 1.50 - - 1.50 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (RESIDENCE G2) Rain Water Harvesting 1 - 1 OK




[-] Floor Details (Table 9)


[-] Building:A (RESIDENCE G2)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:TYPICAL - 1& 2 FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.





[-] Summary (Table 10)

Name Perm./Reqd. Proposed Status
Plot Area - 304.43 OK
Plot Width - 14.05 OK
Plot Depth - 21.67 OK
Access Width - 3.35 OK
Plot Frontage - 13.65 OK
Coverage Area 182.66 182.87 Failed
FARArea
Bldg. FAR Area : 437.68
Sanctioned FAR Area :0.00
646.46 437.68 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth less than 3.60 mt., the Floor Area Ratio-FAR shall be 1.2 {As per Rule No.39, Table 15, Note i}
(2) For Bundu Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
(3) For Bundu Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth less than 3.60 mt., the Floor Area Ratio-FAR shall be 1.2 {As per Rule No.39, Table 15, Note i}
(2) For Bundu Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
(3) For Bundu Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 21-27 mt. and Plot width 10-15 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width upto 3.6 mt. only Stilt + 1 floors shall be allowed {As per Rule No. 39.1 Note 1}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
Building Level (Rooms)