-
No Image Found   

Check List Report

Bundu Nagar Panchayat

Version Number: 1.0.9  
Version Date: 23/01/2017 
Report Generated On: 04-03-2017 
 

General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictRANCHI
AuthorityBUNDU NAGAR PANCHAYAT
Inward_NoBNPC/BP/0001/W03/2017
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageBundu
Taluka14
Architect Details
Architect NameArun Ranjan
License No.BNPC/ARC/0002/2016
Architect Address303, Urmila Apartment, U B Lane Tharpakna
Architect EmailIDdotconsultant@gmail.com
Architect Mobile No9471550077
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No1624
NorthPlot No. - 1624 DIWAKAR HAZAM
SouthPlot No. - 1624 GANESH PRASAD BHAGAT
EastPlot No. - DAKBANGLA CAMPOUND
WestRoad Width - 5.4
Owner's Details
NameKAMAL PRASAD MAHTO
AddressVILL-BUNDU THANA TOLI PO+PS BUNDU RANCHI
Email IDarchitectdot@gmail.com
Mobile No9934180996
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 910.53
2Plot area as per Document by Applicant 801.90
3Physical area measured at site 801.90
4Area as per Drawing 895.52
5Area as per Site Visit NaN

Area of Plot Considered : 801.90

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
Plotplot
Plot OccupancyResidential
Plot SubUse Residential Bldg/Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 801.90
Deduction from Gross Plot area
- Road Widening Area 21.66
21.66
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 780.24
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 684.91
Deductions for Balance Plot Area (from Gross Plot Area)
- Road Widening Area 21.66
- Common Plot 95.33
116.99
Balance Plot Area 684.91

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 468.14
Proposed Coverage Area ( 19.90 % ) 155.25
Total Prop. Coverage Area ( 19.9 % ) 155.25
Balance coverage area ( 40.10 % ) 312.89
FAR CHECK
Perm. FAR Area ( 2.00 ) 1560.48
Total Perm. FAR area 1560.48
Residential FAR 240.53
Proposed FAR Area 240.53
Total Proposed FAR Area 240.53
Consumed FAR (Factor) 0.31
Balance FAR Area 1319.95
BUA CHECK
Total Proposed BuiltUp Area 240.53


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road -
Existing Road Width 5.40
Proposed Road Width as per Master Plan -
Road Widening Width 1.06
Plot size (as per measurement) -


     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 780.24 OK
Plot Width Sq.Mt. - - 21.05 OK
Plot Depth Sq.Mt. - - 41.52 OK
Access Width Sq.Mt. - - 5.40 OK
Plot Frontage Sq.Mt. - - 20.42 OK
Coverage Area Sq.Mt. - 468.14 155.25 OK
FAR Area Sq.Mt. - 1560.48 240.53 OK
Consumed FAR Sq.Mt. - 2.00 0.31 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 78.02 95.33 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 95.33 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 4.93 OK
Tree Cover (Plantation) - Angle Degree - 88.23 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 9 OK
A-1 (BUILDING) Front Margin... ROAD WIDENING AREA Mt. 4.00 - 8.54 OK
Rear Margin Mt. 4.00 - 19.68 OK
Side1 Margin Mt. 1.50 - 2.48 OK
Side2 Margin Mt. 1.50 - 4.57 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (BUILDING) Height Mt. 10.00 6.00 OK
A (BUILDING) First Floor - Height Mt. 2.75 - 3.00 OK
Ground Floor - Height Mt. 2.75 - 3.00 OK
Plinth - Height Mt. 0.45 - 0.60 OK
A (BUILDING) Terrace Floor - Height Mt. 1.00 1.20 1.00 OK
A (BUILDING) No. of Floors No. G + 2 2 OK
No. of Tenements No. - 2 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.050 OK
STAIRCASE - Tread Width Mt. 0.225 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.050 OK
STAIRCASE - Tread Width Mt. 0.225 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.050 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. 2.100 - 2.400 OK
SUMP TANK Area Sq.Mt. - - 6.48 OK
Width Mt. - - 1.80 OK
Depth Mt. - - 3.60 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 6.00 OK
Width Mt. - - 2.00 OK
Depth Mt. - - 3.00 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.90 OK
Width Mt. - - 0.30 OK
Depth Mt. - - 3.00 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 2.25 OK
Width Mt. - - 1.50 OK
Depth Mt. - - 1.50 OK
Height Mt. - - - OK
A (BUILDING) Rain Water Harvesting - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2) For Bundu Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2) For Bundu Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Parking Check FOR POPULATION UPTO 50000 AND RESIDENTIAL USE MULTIFAMILY BUILDING, ONE SPACE FOR EVERY ONE APARTMENT OR PART THERE OF. {AS PER RULE NO. 23 TABLE NO. 7}
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 39-45 mt. and Plot width 21-27 mt., Margin required in Front shall be 4.0 mt., Rear 4.0 mt. and 1.5 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 4.8-6.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 4.8-6.1 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
Building Level (Rooms)


[-] Disclaimer: AutoDCR is an input based Software Tool used by Municipal Corporations but the final Approval lies with concerned Officer/Authority.

The generated Report is subjected to the following manual verification done by the Officials.

1. The results of this Report is to be considered correct only if inputs given to the system in terms of Drawing or Data are correct.
2. This is a system generated Report so results will be totally dependent upon manual operations.
3. The road acquisition, Internal Road, Existing Road, Reservation, Amenity and all other areas to be deducted from the Plot area are checked with the sanctioned Layout of DP and verified that the same area are drawn in Drawing required as per System.
4. The shape, size and dimension of the Plot drawn into Drawing are verified with the demarcation plan and actual site condition.
5. The minimum Plot area considered for calculation in AutoDCR is verified with all the Documental areas.
6. The FAR Poly, Terrace poly and all other entities drawn in Drawing is checked as it is used to verify margins. FAR, Coverage and Parking calculations.
7. The report is checked for all failed entities by AE or JE.