No Image Found

Failed List Report

Bundu Nagar Panchayat

Version Number: 1.0.27
Version Date: 18/05/2018
Report Generated On: 14-06-2018

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictRANCHI
AuthorityBUNDU NAGAR PANCHAYAT
Inward_NoBNPC/BP/0006/W03/2017
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageBundu
Taluka14
Architect Details
Architect Namejigyashu kumar
License No.BNPC/ARC/0003/2016
Architect Addressjigyashu kumar and consultant above allhabad bank main roar raj complex ramgarh cantt
Architect EmailIDjigyashukumar@gmail.com
Architect Mobile No9835130034
Plot Details
Plot Use Residential
Plot SubUse Boarding
PlotNearbyReligiousStructure NA
Plot/SubPlot No92
NorthPlot No. - USHA DEVI
SouthPlot No. - KRISHNA CHANDRA MAHTO
EastRoad Width - 4
WestPlot No. - RAJU KUMAR MAHTA
Owner's Details
NameASHOK KUMAR MAHTO
AddressVILL: ADARSH NAGAR, N.H-33, NEAR IB, BUNDU, RANCHI DIST-RANCHI (JHARKHAND)
Email IDjigyasukumar@gmail.com
Mobile No9470935024
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 343.98
2 Plot area as per Document by Applicant 343.98
3 Physical area measured at site 343.98
4 Area as per Site Visit (Site Visit Report) 343.98
5Area as per Drawing 329.82

Area of Plot Considered : 329.82

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Boarding
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 329.82
Deduction from Gross Plot area
- Surrender Free of Cost 50.85
50.85
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 278.97
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 241.46
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 50.85
- Common Plot 37.51
88.36
Balance Plot Area 241.46

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 167.38
Proposed Coverage Area ( 34.53 % ) 96.34
Total Prop. Coverage Area ( 34.53 % ) 96.34
Balance coverage area ( 25.47 % ) 71.04
FAR CHECK
Perm. FAR Area ( 1.50 ) 494.73
Total Perm. FAR area 494.73
Residential FAR 192.69
Proposed FAR Area 192.69
Total Proposed FAR Area 192.69
Consumed FAR (Factor) 0.58
Balance FAR Area 302.04
BUA CHECK
Total Proposed BuiltUp Area 192.68


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 400 meter and upto 500 meter -
Existing Road Width 4 4.00
Proposed Road Width as per Master Plan 7.5 -
Road Widening Width 1.75 1.76
Plot size (as per measurement) 343.98 329.82





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For Bundu Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For Bundu Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth upto 10.0 mt. and Plot width 27-33 mt., Margin required in Front shall be 1.5 mt., Rear 0.9 mt. and 1.5 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Exceeding 300 mt. shall be 7.50 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 300 mt. shall be 7.50 mt. {As per Rule No. 34 Table No. 6}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) -
(6) No need to check distance from Building SOLAR HEATING SYSTEM
Building Level (Rooms)