No Image Found   

Detail Scrutiny Report

Bundu Nagar Panchayat

Version Number: 1.0.42  
Version Date: 29/04/2019 
Report Generated On: 25-10-2019 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictRANCHI
AuthorityBUNDU NAGAR PANCHAYAT
Inward_NoBNPC/BP/0001/W03/2018
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageBundu
Taluka14
Architect Details
Architect NameArun Ranjan
License No.BNPC/ARC/0002/2016
Architect Address303, Urmila Apartment, U B Lane Tharpakna
Architect EmailIDdotconsultant@gmail.com
Architect Mobile No9471550077
Plot Details
Plot Use Commercial
Plot SubUse ResiComm Bldg
PlotNearbyReligiousStructure NA
Plot/SubPlot No67
NorthRoad Width - 60.975 (NH 33 - RANCHI TATA ROAD)
SouthPlot No. - PRIVATE PLOT
EastRoad Width - 3 (SERVICE ROAD)
WestPlot No. - GOBRA QUARY
Owner's Details
NameMADAN MOHAN BHAGAT
AddressBUNDU, RANCHI
Email IDarchitectdot@gmail.com
Mobile No9471301391
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 809.45
2 Plot area as per Document by Applicant 696.47
3 Physical area measured at site 696.85
4 Area as per Site Visit (Site Visit Report) 696.85
5Area as per Drawing 696.47

Area of Plot Considered : 696.47

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyCommercial
Plot SubUse ResiComm Bldg
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 696.47
Deduction from Gross Plot area
- Surrender Free of Cost 57.72
57.72
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 638.75
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 555.71
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 57.72
- Common Plot 83.04
140.76
Balance Plot Area 555.71

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 319.38
Proposed Coverage Area ( 48.63 % ) 310.60
Total Prop. Coverage Area ( 48.63 % ) 310.60
Balance coverage area ( 1.37 % ) 8.78
FAR CHECK
Perm. FAR Area ( 2.00 ) 1392.94
Total Perm. FAR area 1392.94
Residential FAR 297.48
Commercial FAR 911.38
Proposed FAR Area 1223.36
Total Proposed FAR Area 1223.36
Consumed FAR (Factor) 1.76
Balance FAR Area 169.58
BUA CHECK
Total Proposed BuiltUp Area 1573.87


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 60.97 60.97
Proposed Road Width as per Master Plan 60.975 -
Road Widening Width 0 38.10
Plot size (as per measurement) 696.85 696.47
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 63.88 83.04 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 41.52 0.00 0.00 - 2.40 - 90.00 ROAD WIDENING AREA(SURRENDERED FREE OF COST) OK
Tree Cover (Plantation) - 41.52 0.00 0.00 - 2.40 - 90.00 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 20 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (COMM RESI) Commercial ResiComm Bldg Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (COMM RESI) 98.56 12.00 12.30 12.00 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (COMM RESI) Third Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.75 OK
Second Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.75 OK
First Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.75 OK
Ground Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.75 OK
Basement Floor 2.40 - 2.70 2.40 - 2.60 2.10 - 2.40 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (COMM RESI) Terrace Floor 1.00 1.20 1.00 OK
   
   
[-] Basement Floor Check (Table 4a-3)
Building Name Floor Name Height Below GL Area Ventilation Area (Sq.mt.) Status
Perm Prop Perm Prop Reqd Prop
A (COMM RESI) Basement Floor - 1.20 - 310.60 - 0.38 OK


[-] Basement Floor Area Check
Building Name Area Status
Perm Prop
A (COMM RESI) - 310.60
Total - 310.60 OK

1 [-] Basement Margin Check
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
  A-1 (COMM RESI)   60.975 mt. Wide MainRoad 3.00 7.10 3.00 4.60 2.50 2.50 2.50 2.50 OK

    >
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (COMM RESI) - 4 - 7 OK


[-] Basement Floor Number Check
Building Name No. of Basement Floor Status
Perm Prop
A (COMM RESI) 1 1 OK
 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
319.38 310.60 OK
50% 48.63%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (COMM RESI) - 310.60
  Total Prop. Coverage Area - 310.60
  Total Coverage Area 319.38 310.60

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Lift Lobby Balcony Void Parking Resi. Commercial Stair Passage
A (COMM RESI) 1 1573.87 29.10 13.11 17.49 3.31 287.50 297.48 911.38 11.81 2.69 1223.36 1223.36 07
Grand Total : 1 1573.87 29.10 13.11 17.49 3.31 287.50 297.48 911.38 11.81 2.69 1223.36 1223.36 07


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (COMM RESI)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Basement Floor 310.60 14.50 310.60 14.50
Ground Floor 310.60 310.60 310.60 310.60
First Floor 310.59 299.09 310.59 299.09
Second Floor 319.51 301.69 319.51 301.69
Third Floor 322.57 297.48 322.57 297.48
Terrace Floor 0.00 0.00 0.00 0.00
Total : 1573.87 1223.36 1573.87 1223.36


[-] UnitBUA Table for Building :A (COMM RESI)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN HALL OTHER 285.32 265.37 3 1
FIRST FLOOR PLAN SHOPS SHOP 287.28 250.96 16 1
SECOND FLOOR PLAN HOTEL SHOP 280.96 243.58 41 1
THIRD FLOOR PLAN FLAT 1 FLAT 76.32 60.43 10 4
FLAT 2 FLAT 70.03 52.04 8
FLAT 3 FLAT 76.48 60.25 10
FLAT 4 FLAT 72.39 54.41 9
Total: - - 1148.77 987.03 97 7


[-] Building :A (COMM RESI)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Lift Lobby Balcony Void Parking Resi. Commercial Stair Passage
Basement Floor 310.60 8.60 0.00 0.00 0.00 287.50 0.00 0.00 11.81 2.69 14.50 14.50 00
Ground Floor 310.60 0.00 0.00 0.00 0.00 0.00 0.00 310.60 0.00 0.00 310.60 310.60 01
First Floor 310.59 4.30 7.20 0.00 0.00 0.00 0.00 299.09 0.00 0.00 299.09 299.09 01
Second Floor 319.51 8.60 5.91 0.00 3.31 0.00 0.00 301.69 0.00 0.00 301.69 301.69 01
Third Floor 322.57 7.60 0.00 17.49 0.00 0.00 297.48 0.00 0.00 0.00 297.48 297.48 04
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 1573.87 29.10 13.11 17.49 3.31 287.50 297.48 911.38 11.81 2.69 1223.36 1223.36 07
Total Number of Same Buildings : 1
Total : 1573.87 29.10 13.11 17.49 3.31 287.50 297.48 911.38 11.81 2.69 1223.36 1223.36 07
[-] Table 4c-2

  FAR Area
Building FAR Area:1223.36
Existing FAR Area :0.00
Perm.
1392.94
Prop.
1223.36
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (COMM RESI) 60.975 mt. Wide MainRoad 7.00 7.10 4.50 4.60 2.50 2.50 2.50 2.50 OK






[-] Inner Building Details (Table 6)
   
   
[-] Balcony Details (Table 6c)

[-] For Building:A (COMM RESI)
Floor Name Balcony Name Width Status
Perm Prop
THIRD FLOOR PLAN BALCONY 1.20 1.20 OK
BALCONY 1.20 1.20 OK
BALCONY 1.20 1.09 OK
BALCONY 1.20 1.09 OK
BALCONY 0.90 0.90 OK
BALCONY 0.90 0.90 OK
BALCONY 1.20 0.90 OK
BALCONY 1.20 0.90 OK



For PWork At Layout : 

No Balcony Found.

   
   
   
[-] Passage Details

[-] For Building :A (COMM RESI)
Floor Name Passage Name Area Width Length Status
Prop Reqd Prop Perm Prop
BASEMENT FLOOR PLAN 1.25 mt. Wide Passage 2.69 1.00 1.25 - 2.15 OK

   
   
   
[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Status
Prop Reqd Prop
A (COMM RESI) 12.00 2 2 OK

[-] Lift Check Table

[-] For Building :A (COMM RESI)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
BASEMENT FLOOR PLAN Lift 1.70 2.00 1.90 2.15 OK
Lift 1.70 2.00 1.90 2.15 OK
GROUND FLOOR PLAN Lift Lobby 1.70 1.85 1.90 1.90 OK
Lift 1.70 2.00 1.90 2.15 OK
Lift 1.70 2.00 1.90 2.15 OK
FIRST FLOOR PLAN Lift Lobby 1.70 2.15 1.90 3.35 OK
Lift 1.70 2.00 1.90 2.15 OK
SECOND FLOOR PLAN Lift Lobby 1.70 2.15 1.90 2.75 OK
Lift 1.70 2.00 1.90 2.15 OK
Lift 1.70 2.00 1.90 2.15 OK
THIRD FLOOR PLAN Lift 1.70 1.90 1.90 2.00 OK
Lift 1.70 1.90 1.90 2.00 OK
TERRACE FLOOR PLAN Lift Machine Room 1.70 2.15 1.90 5.23 OK

   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car Visitors Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (COMM RESI) Commercial Shop and Office > 0 200 285.32 1 1 - - - - - - -
> 0 200 285.32 - - - - - - 1 3 -
ResiComm Bldg > 0 200 577.16 1 2 - - - - - - -
> 0 200 577.16 - - - - - - 1 7 -
Residential Residential Bldg/Apartment > 0 1 4.00 1 4 - - - - - - -
> 0 1 4.00 - - - - - - 1 4 -
> 0 1 4.00 - - - 1 1 - - - -
Total : - - - - 7 18 - 1 2 - 14 15

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 18 225.00 OK
Total Car 7 87.50 18 225.00 OK
Visitor's Car Parking - - 2 25.00 OK
Total Visitor Parking 1 12.50 2 25.00 OK
TwoWheeler - - 15 30.00 OK
Total TwoWheeler 14 28.00 15 30.00 OK
Other Parking - - - 123.00 OK
Total 128.00 458.00 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

Driveway Parking Checks (Table 7d)
Plot Level Parking Driveway is as per the Rules
Floor Level Parking Driveway is as per the Rules
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (COMM RESI)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
BASEMENT FLOOR PLAN STAIRCASE 0.900 1.050 0.250 0.250 0.200 0.000 - 0 - - 0.000 OK
GROUND FLOOR PLAN STAIRCASE 0.900 1.050 0.250 0.250 0.200 0.150 - 10 - - 0.000 OK
FIRST FLOOR PLAN STAIRCASE 0.900 1.050 0.250 0.250 0.200 0.150 - 10 - - 0.000 OK
SECOND FLOOR PLAN STAIRCASE 0.900 1.050 0.250 0.250 0.200 0.150 - 10 - - 0.000 OK
THIRD FLOOR PLAN STAIRCASE 0.900 1.050 0.250 0.250 0.200 0.150 - 10 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.050 - 0.250 - 0.000 - 0 - - 2.400 OK

   
   
   

[-] Ramp Checks (Table 8b-a)
Ramp Name Width Depth Slope Status
Reqd Prop Reqd Prop Reqd Perm Prop
10.50 mt. long 1.80 mt. High 3.60 mt. Wide Natural Slope - 3.60 - 1.80 - - - OK


[-] Ramp Checks (Table 8b)
Building Name Floor Name No. Status
Reqd Prop
A (COMM RESI) BASEMENT FLOOR PLAN 1 1 OK

   
   
[-] Arch Projection Checks (Table 8c - a)

[-] For Building :A (COMM RESI)
Floor Name Arch Proj Name Width Depth Area Status
Perm Prop Perm Prop Perm Prop
SECOND FLOOR PLAN C.B. 0.60 0.48 - 3.01 - 1.43 OK
C.B. 0.60 0.48 - 3.14 - 1.49 OK
C.B. 0.60 0.48 - 1.68 - 0.80 OK
C.B. 0.60 0.48 - 1.68 - 0.80 OK
C.B. 0.60 0.48 - 1.58 - 0.75 OK
C.B. 0.60 0.48 - 1.63 - 0.77 OK
C.B. 0.60 0.48 - 3.03 - 1.44 OK
C.B. 0.60 0.48 - 3.05 - 1.45 OK
THIRD FLOOR PLAN C.B. 0.60 0.48 - 1.60 - 0.76 OK
C.B. 0.60 0.48 - 1.73 - 0.82 OK
C.B. 0.60 0.48 - 1.73 - 0.82 OK
C.B. 0.60 0.48 - 1.60 - 0.76 OK
   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SUMP TANK - - 4.78 - - 1.55 - - 3.07 - - 0.00 OK
RAIN WATER HARVESTING - - 4.50 - - 1.36 - - 3.30 - - 0.00 OK
ENT.GATE - - 0.90 - - 0.25 - - 3.60 - - 0.00 OK
ENT.GATE - - 0.90 - - 0.25 - - 3.60 - - 0.00 OK
SOLAR HEATING SYSTEM - - 19.41 - - 3.48 - - 5.58 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (COMM RESI) Rain Water Harvesting 1 - 1 OK
Entrance Gate 1 - 2 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (COMM RESI)


[-] Floor:BASEMENT FLOOR PLAN



No Room Found.


[-] Floor:GROUND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:FIRST FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:SECOND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:THIRD FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 638.75 OK
  Plot Width - 16.76 OK
  Plot Depth - 38.10 OK
  Access Width - 60.97 OK
  Plot Frontage - 18.28 OK
  Coverage Area 319.38 310.60 OK
  FAR Area
Bldg. FAR Area : 1223.36
Sanctioned FAR Area :0.00
1392.94 1223.36 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 3.0 {As per Rule No.39, Table 15}
(2) For Bundu Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 3.0 {As per Rule No.39, Table 15}
(2) For Bundu Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) ; In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
(3) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(4) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Commercial Building upto 16.4 mt. Ht. having Plot Depth 33-39 mt. and Plot width 15-21 mt., Margin required in Front shall be 7.0 mt., Rear 4.5 mt. and 2.5 mt. shall be provided on both side. {As per Rule No. 36 Table 10 & 11}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 3 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Building Height For old area, on Road width above 18.30 mt., No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Below GL Floor Height ,
Basement Floor No. Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
Floor Number For old area location,on Road width 18.30 mt. and above, No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
Balcony (1) For setback more than 2.5 meters projected balcony shall be allowed with a width of 1.2 meters {As per Rule No. 46.4}
(2) Projected balcony shall be allowed with a width of 0.9 meters where the setback is between 2.0 meters to 2.5 meters {As per Rule No. 46.4}
Passage No exit doorway shall be less than 1.00 m. in width. {As per Rule No.43.4.2} ;
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Non-Residential Building, Minimum number of lifts to be 2 for all non-residential building above ground + 2 and the minimum capacity shall be 6 persons per floor. {As per Rule No. 49.2.3 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Arch Projection (1) No need to check
(2) Cupboard up to 0.60 mt. in width shall be permitted. {As per Rule 6.26.1 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)