RegionJHARKHAND URBAN LOCAL BODIES
DistrictRANCHI
AuthorityBUNDU NAGAR PANCHAYAT
Inward_NoBNPC/BP/0002/W03/2020
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageBundu
Taluka14
Architect Details
Architect NameArun Ranjan
License No.BNPC/ARC/0002/2016
Architect Address303, Urmila Apartment, U B Lane Tharpakna
Architect EmailIDdotconsultant@gmail.com
Architect Mobile No9471550077
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No91
NorthPlot No. - 91
SouthPlot No. - 92
EastPlot No. - 91
WestRoad Width - 7.92
Owner's Details
NameSITARAM MAHTO
AddressVILL-SOSODIH,P.S.-BAREDIH ,DISTRICT-RANCHI,THANA-TAMAR
Email IDarchitectdot@gmail.com
Mobile No7903733102
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 243.03
2 Plot area as per Document by Applicant 243.03
3 Area as per Site Visit (Site Visit Report) 241.67
4Area as per Drawing 241.37

Area of Plot Considered : 241.37

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 241.37
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 241.37
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 217.08
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 24.29
24.29
Balance Plot Area 217.08

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 144.82
Proposed Coverage Area ( 48.40 % ) 116.83
Total Prop. Coverage Area ( 48.4 % ) 116.83
Balance coverage area ( 11.60 % ) 27.99
FAR CHECK
Perm. FAR Area ( 2.00 ) 482.74
Total Perm. FAR area 482.74
Residential FAR 207.66
Proposed FAR Area 207.66
Total Proposed FAR Area 207.66
Consumed FAR (Factor) 0.86
Balance FAR Area 275.08
BUA CHECK
Total Proposed BuiltUp Area 233.66


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 600 meter and upto 1000 meter -
Existing Road Width 8.8 8.80
Proposed Road Width as per Master Plan 7.5 -
Road Widening Width 0 -
Plot size (as per measurement) 241.67 241.37
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 241.37 OK
Plot Width Mt. - - 16.67 OK
Plot Depth Mt. - - 14.48 OK
Access Width Mt. - - 8.80 OK
Plot Frontage Mt. - - 16.67 OK
Coverage Area Sq.Mt. - 144.82 116.83 OK
FAR Area Sq.Mt. - 482.74 207.66 OK
Consumed FAR Sq.Mt. - 2.00 0.86 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 12.07 24.29 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 24.29 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 1.46 OK
Tree Cover (Plantation) - Angle Degree - 89.86 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 2 6 OK
A-1 (RESIDENCE G1) Front Margin... 8.80 mt. Wide MainRoad Mt. 2.00 - 2.93 OK
Rear Margin Mt. 1.50 - 1.50 OK
Side1 Margin Mt. 1.00 - 4.05 OK
Side2 Margin Mt. 1.00 - 1.00 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (RESIDENCE G1) Height Mt. 16.13 6.30 OK
A (RESIDENCE G1) First Floor - Height Mt. 2.75 - 3.15 OK
First Floor - Clear Height Mt. 2.75 - 3.05 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.70 OK
Ground Floor - Height Mt. 2.75 - 3.15 OK
Ground Floor - Clear Height Mt. 2.75 - 3.05 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.70 OK
A (RESIDENCE G1) Terrace Floor - Height Mt. - - 1.00 OK
A (RESIDENCE G1) No. of Floors No. G + 5 2 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.050 OK
STAIRCASE - Tread Width Mt. 0.225 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.050 OK
STAIRCASE - Tread Width Mt. 0.225 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.050 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. 2.100 - 2.400 OK
SUMP TANK Area Sq.Mt. - - 7.15 OK
Width Mt. - - 2.57 OK
Depth Mt. - - 2.79 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 5.57 OK
Width Mt. - - 2.00 OK
Depth Mt. - - 2.79 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 1.79 OK
Width Mt. - - 0.46 OK
Depth Mt. - - 3.90 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 10.78 OK
Width Mt. - - 1.88 OK
Depth Mt. - - 5.75 OK
Height Mt. - - - OK
A (RESIDENCE G1) Rain Water Harvesting - No No. 1 - 1 OK
Ramp No. A (RESIDENCE G1) - GROUND FLOOR PLAN - No. No. 1 0 Failed
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Bundu Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Bundu Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 10-15 mt. and Plot width 15-21 mt., Margin required in Front shall be 2.0 mt., Rear 1.5 mt. and 1.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 7.50-9.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 19.25 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 7.5-9.1 mt. only G+5 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)