No Image Found   

Detail Scrutiny Report

Bundu Nagar Panchayat

Version Number: 1.0.60  
Version Date: 16/10/2020 
Report Generated On: 16-09-2021 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictRANCHI
AuthorityBUNDU NAGAR PANCHAYAT
Inward_NoBNPC/BP/0002/W03/2020
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageBundu
Taluka14
Architect Details
Architect NameArun Ranjan
License No.BNPC/ARC/0002/2016
Architect Address303, Urmila Apartment, U B Lane Tharpakna
Architect EmailIDdotconsultant@gmail.com
Architect Mobile No9471550077
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No91
NorthPlot No. - 91
SouthPlot No. - 92
EastPlot No. - 91
WestRoad Width - 7.92
Owner's Details
NameSITARAM MAHTO
AddressVILL-SOSODIH,P.S.-BAREDIH ,DISTRICT-RANCHI,THANA-TAMAR
Email IDarchitectdot@gmail.com
Mobile No7903733102
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 243.03
2 Plot area as per Document by Applicant 243.03
3 Area as per Site Visit (Site Visit Report) 241.67
4Area as per Drawing 241.37

Area of Plot Considered : 241.37

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 241.37
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 241.37
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 217.08
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 24.29
24.29
Balance Plot Area 217.08

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 144.82
Proposed Coverage Area ( 48.40 % ) 116.83
Total Prop. Coverage Area ( 48.4 % ) 116.83
Balance coverage area ( 11.60 % ) 27.99
FAR CHECK
Perm. FAR Area ( 2.00 ) 482.74
Total Perm. FAR area 482.74
Residential FAR 207.66
Proposed FAR Area 207.66
Total Proposed FAR Area 207.66
Consumed FAR (Factor) 0.86
Balance FAR Area 275.08
BUA CHECK
Total Proposed BuiltUp Area 233.66


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 600 meter and upto 1000 meter -
Existing Road Width 8.8 8.80
Proposed Road Width as per Master Plan 7.5 -
Road Widening Width 0 -
Plot size (as per measurement) 241.67 241.37
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 12.07 24.29 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 24.29 0.00 0.00 - 1.46 - 89.86 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 6 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (RESIDENCE G1) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (RESIDENCE G1) 16.13 6.30 6.30 6.45 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (RESIDENCE G1) First Floor 2.75 - 3.15 2.75 - 3.05 2.40 - 2.70 OK
Ground Floor 2.75 - 3.15 2.75 - 3.05 2.40 - 2.70 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (RESIDENCE G1) Terrace Floor - - 1.00 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (RESIDENCE G1) G + 5 2 - 1 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
144.82 116.83 OK
60% 48.4%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (RESIDENCE G1) - 116.83
  Total Prop. Coverage Area - 116.83
  Total Coverage Area 144.82 116.83

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Parking Resi.
A (RESIDENCE G1) 1 233.66 26.00 207.66 207.66 207.66 01
Grand Total : 1 233.66 26.00 207.66 207.66 207.66 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (RESIDENCE G1)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 116.83 90.83 116.83 90.83
First Floor 116.83 116.83 116.83 116.83
Terrace Floor 0.00 0.00 0.00 0.00
Total : 233.66 207.66 233.66 207.66


[-] UnitBUA Table for Building :A (RESIDENCE G1)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT A FLAT 181.58 156.71 9 1
FIRST FLOOR PLAN SPLIT A FLAT 0.00 0.00 10 0
Total: - - 181.58 156.71 19 1


[-] Building :A (RESIDENCE G1)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Parking Resi.
Ground Floor 116.83 26.00 90.83 90.83 90.83 01
First Floor 116.83 0.00 116.83 116.83 116.83 00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 00
Total : 233.66 26.00 207.66 207.66 207.66 01
Total Number of Same Buildings : 1
Total : 233.66 26.00 207.66 207.66 207.66 01
[-] Table 4c-2

  FAR Area
Building FAR Area:207.66
Existing FAR Area :0.00
Perm.
482.74
Prop.
207.66
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (RESIDENCE G1) 8.80 mt. Wide MainRoad 2.00 2.93 1.50 1.50 1.00 4.05 1.00 1.00 OK






[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/ Dwelling / Non Apartment, In Building: A (RESIDENCE G1)
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (RESIDENCE G1)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.750 1.050 0.225 0.250 0.200 0.150 - 11 - - 0.000 OK
FIRST FLOOR PLAN STAIRCASE 0.750 1.050 0.225 0.250 0.200 0.150 - 11 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.050 - 0.250 - 0.000 - 0 2.100 - 2.400 OK

   
   
   



No Ramp Found.


[-] Ramp Checks (Table 8b)
Building Name Floor Name No. Status
Reqd Prop
A (RESIDENCE G1) GROUND FLOOR PLAN 1 0 Failed

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SUMP TANK - - 7.15 - - 2.57 - - 2.79 - - 0.00 OK
RAIN WATER HARVESTING - - 5.57 - - 2.00 - - 2.79 - - 0.00 OK
ENT.GATE - - 1.79 - - 0.46 - - 3.90 - - 0.00 OK
SOLAR HEATING SYSTEM - - 10.78 - - 1.88 - - 5.75 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (RESIDENCE G1) Rain Water Harvesting 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (RESIDENCE G1)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:FIRST FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 241.37 OK
  Plot Width - 16.67 OK
  Plot Depth - 14.48 OK
  Access Width - 8.80 OK
  Plot Frontage - 16.67 OK
  Coverage Area 144.82 116.83 OK
  FAR Area
Bldg. FAR Area : 207.66
Sanctioned FAR Area :0.00
482.74 207.66 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Bundu Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Bundu Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 10-15 mt. and Plot width 15-21 mt., Margin required in Front shall be 2.0 mt., Rear 1.5 mt. and 1.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 7.50-9.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 19.25 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 7.5-9.1 mt. only G+5 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)