No Image Found

PreDCR Report

BUNDU NAGAR PANCHAYAT

Version Number: 1.0.61
Version Date: 16/10/2020
Report Generated On : 28-10-2021

General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictRANCHI
AuthorityBUNDU NAGAR PANCHAYAT
AuthorityNameBundu Nagar Panchayat
Inward_NoBNPC/BP/0002/W03/2021
Application TypeGeneral Proposal
Project TypeBuilding Permission
Case TypeNew
LocationOld Area
SubLocationNA
Ward NoW03
Village/Mauza NameBundu
Architect Details
Architect NamePriyanka
License No.BNPC/ARC/0002/2021
Architect AddressManjhi Toli Bundu, PO- Bundu, PS-Bundu, Dist- Rnachi
Architect EmailIDmanjhipriyanka@gmail.com
Architect Mobile No7319055391
Plot Details
Plot UseResidential
Plot SubUseBungalow/ Dwelling / Non Apartment
Land Use ZoneResidential
AbuttingRoadWidth3.9
Plot No1853
Khata No971
Holding No0020000035000A1
Thana No28
NorthPlot No. - PRAMOD DUTTA
SouthRoad Width - 3
EastPlot No. - COPERATIVE ROAD
WestRoad Width - 3.9
Developer Details
Builder Name
Builder License No.
 
 
Owner's Details
NameSHIVANI DUTTA
AddressCHOWK BAZAR ROAD BUNDU NEAR JAIN TEMPLE
OWNERS_EMAILIDduttamithun1221@gmail.com
OWNERS_MOBILENO9931514330
 

AutoDCR reports can not be generated due to following failing entities on PreDCR Layer:

Failed Information:
    Failed Plot
Plot Name Failed Information Entity Reference
PLOT Entity is supposed to touching one of following entities : Passage . 86F1D

Failed MainRoad
MainRoad Name Failed Information Entity Reference
4.25 M WIDE MAINROAD Entity is supposed to touching one of following entities : GroundLevel Passage . 86F20

Failed RoadWidening
Plot Name RoadWidening Name Failed Information Entity Reference
PLOT ROAD WIDENING AREA(SURRENDERED FREE OF COST) Entity is supposed to touching one of following entities : GroundLevel Passage . 86F24

Failed AccessoryUse
Plot Name AccessoryUse Name Failed Information Entity Reference
PLOT Sewage Treatment Plant Entity is supposed to inside one of following entities : . 86FE9
SUMP TANK Entity is supposed to inside one of following entities : . 86FEA
RAIN WATER HARVESTING Entity is supposed to inside one of following entities : . 86FF1

Failed Room
Building Name Floor Name Room Name Failed Information Entity Reference
A (DUTTA RESIDENCE) SECOND FLOOR PLAN BED ROOM 3.00X3.60 Entity is supposed to inside one of following entities : . 86880
SECOND FLOOR PLAN TOILET 2.40X1.50 Entity is supposed to inside one of following entities : . 86881
SECOND FLOOR PLAN TOILET 2.40X1.50 Entity is supposed to inside one of following entities : . 86882
SECOND FLOOR PLAN BED ROOM 3.00X4.22 Entity is supposed to inside one of following entities : . 86883
SECOND FLOOR PLAN BED ROOM 3.00X3.08 Entity is supposed to inside one of following entities : . 86886
SECOND FLOOR PLAN BED ROOM 3.00X3.60 Entity is supposed to inside one of following entities : . 86889
SECOND FLOOR PLAN TOILET 2.40X1.50 Entity is supposed to inside one of following entities : . 8688A
SECOND FLOOR PLAN TOILET 2.40X1.50 Entity is supposed to inside one of following entities : . 8688B
SECOND FLOOR PLAN BED ROOM 3.00X4.22 Entity is supposed to inside one of following entities : . 8688C
SECOND FLOOR PLAN BED ROOM 3.00X3.08 Entity is supposed to inside one of following entities : . 86903
SECOND FLOOR PLAN LIVING/KITCHEN 3.08X8.07 Entity is supposed to inside one of following entities : . 86917
SECOND FLOOR PLAN PASSAGE 0.60X3.13 Entity is supposed to inside one of following entities : . 8691B
SECOND FLOOR PLAN LIVING/KITCHEN 3.08X8.07 Entity is supposed to inside one of following entities : . 8691F
SECOND FLOOR PLAN PASSAGE 0.60X3.13 Entity is supposed to inside one of following entities : . 86921
SECOND FLOOR PLAN PASSAGE 2.40X4.55 Entity is supposed to inside one of following entities : . 869FB
FIRST FLOOR PLAN BED ROOM 3.00X3.60 Entity is supposed to inside one of following entities : . 86EB3
FIRST FLOOR PLAN TOILET 2.40X1.50 Entity is supposed to inside one of following entities : . 86EB4
FIRST FLOOR PLAN TOILET 2.40X1.50 Entity is supposed to inside one of following entities : . 86EB5
FIRST FLOOR PLAN BED ROOM 3.00X4.22 Entity is supposed to inside one of following entities : . 86EB6
FIRST FLOOR PLAN BED ROOM 3.00X3.08 Entity is supposed to inside one of following entities : . 86EB7
FIRST FLOOR PLAN BED ROOM 3.00X3.60 Entity is supposed to inside one of following entities : . 86EB8
FIRST FLOOR PLAN TOILET 2.40X1.50 Entity is supposed to inside one of following entities : . 86EB9
FIRST FLOOR PLAN TOILET 2.40X1.50 Entity is supposed to inside one of following entities : . 86EBA
FIRST FLOOR PLAN BED ROOM 3.00X4.22 Entity is supposed to inside one of following entities : . 86EBB
FIRST FLOOR PLAN BED ROOM 3.00X3.08 Entity is supposed to inside one of following entities : . 86EBC
FIRST FLOOR PLAN LIVING/KITCHEN 3.08X8.07 Entity is supposed to inside one of following entities : . 86EC7
FIRST FLOOR PLAN PASSAGE 0.60X3.13 Entity is supposed to inside one of following entities : . 86EC9
FIRST FLOOR PLAN LIVING/KITCHEN 3.08X8.07 Entity is supposed to inside one of following entities : . 86ECB
FIRST FLOOR PLAN PASSAGE 0.60X3.13 Entity is supposed to inside one of following entities : . 86ECD
FIRST FLOOR PLAN PASSAGE 2.40X4.55 Entity is supposed to inside one of following entities : . 86ECF

Failed Door
Building Name Floor Name Door Name Failed Information Entity Reference
A (DUTTA RESIDENCE) TERRACE FLOOR PLAN D1 Entity is supposed to touching one of following entities : . 86B64
SECOND FLOOR PLAN D1 Entity is supposed to touching one of following entities : . 86B68
SECOND FLOOR PLAN D1 Entity is supposed to touching one of following entities : . 86B6A
SECOND FLOOR PLAN D2 Entity is supposed to touching one of following entities : . 86B70
SECOND FLOOR PLAN D2 Entity is supposed to touching one of following entities : . 86B72
SECOND FLOOR PLAN D2 Entity is supposed to touching one of following entities : . 86B74
SECOND FLOOR PLAN D2 Entity is supposed to touching one of following entities : . 86B76
SECOND FLOOR PLAN D2 Entity is supposed to touching one of following entities : . 86B78
SECOND FLOOR PLAN D2 Entity is supposed to touching one of following entities : . 86B7A
SECOND FLOOR PLAN D3 Entity is supposed to touching one of following entities : . 86B80
SECOND FLOOR PLAN D3 Entity is supposed to touching one of following entities : . 86B82
SECOND FLOOR PLAN D3 Entity is supposed to touching one of following entities : . 86B84
SECOND FLOOR PLAN D3 Entity is supposed to touching one of following entities : . 86B86
FIRST FLOOR PLAN D1 Entity is supposed to touching one of following entities : . 86ED2
FIRST FLOOR PLAN D1 Entity is supposed to touching one of following entities : . 86ED4
FIRST FLOOR PLAN D2 Entity is supposed to touching one of following entities : . 86ED6
FIRST FLOOR PLAN D2 Entity is supposed to touching one of following entities : . 86ED8
FIRST FLOOR PLAN D2 Entity is supposed to touching one of following entities : . 86EDA
FIRST FLOOR PLAN D2 Entity is supposed to touching one of following entities : . 86EDC
FIRST FLOOR PLAN D2 Entity is supposed to touching one of following entities : . 86EDE
FIRST FLOOR PLAN D2 Entity is supposed to touching one of following entities : . 86EE0
FIRST FLOOR PLAN D3 Entity is supposed to touching one of following entities : . 86EE2
FIRST FLOOR PLAN D3 Entity is supposed to touching one of following entities : . 86EE4
FIRST FLOOR PLAN D3 Entity is supposed to touching one of following entities : . 86EE6
FIRST FLOOR PLAN D3 Entity is supposed to touching one of following entities : . 86EE8

Failed Window
Building Name Floor Name Window Name Failed Information Entity Reference
A (DUTTA RESIDENCE) SECOND FLOOR PLAN W1 Entity is supposed to inside one of following entities : . 86C64
SECOND FLOOR PLAN W1 Entity is supposed to inside one of following entities : . 86C66
SECOND FLOOR PLAN W2 Entity is supposed to inside one of following entities : . 86C6C
SECOND FLOOR PLAN W2 Entity is supposed to inside one of following entities : . 86C6E
SECOND FLOOR PLAN W2 Entity is supposed to inside one of following entities : . 86C70
SECOND FLOOR PLAN W2 Entity is supposed to inside one of following entities : . 86C72
SECOND FLOOR PLAN W2 Entity is supposed to inside one of following entities : . 86C74
SECOND FLOOR PLAN W2 Entity is supposed to inside one of following entities : . 86C76
SECOND FLOOR PLAN V Entity is supposed to inside one of following entities : . 86C7C
SECOND FLOOR PLAN V Entity is supposed to inside one of following entities : . 86C7E
SECOND FLOOR PLAN V Entity is supposed to inside one of following entities : . 86C80
SECOND FLOOR PLAN V Entity is supposed to inside one of following entities : . 86C82
SECOND FLOOR PLAN W2 Entity is supposed to inside one of following entities : . 86C84
FIRST FLOOR PLAN W1 Entity is supposed to inside one of following entities : . 86EEA
FIRST FLOOR PLAN W1 Entity is supposed to inside one of following entities : . 86EEC
FIRST FLOOR PLAN W2 Entity is supposed to inside one of following entities : . 86EEE
FIRST FLOOR PLAN W2 Entity is supposed to inside one of following entities : . 86EF0
FIRST FLOOR PLAN W2 Entity is supposed to inside one of following entities : . 86EF2
FIRST FLOOR PLAN W2 Entity is supposed to inside one of following entities : . 86EF4
FIRST FLOOR PLAN W2 Entity is supposed to inside one of following entities : . 86EF6
FIRST FLOOR PLAN W2 Entity is supposed to inside one of following entities : . 86EF8
FIRST FLOOR PLAN V Entity is supposed to inside one of following entities : . 86EFA
FIRST FLOOR PLAN V Entity is supposed to inside one of following entities : . 86EFC
FIRST FLOOR PLAN V Entity is supposed to inside one of following entities : . 86EFE
FIRST FLOOR PLAN V Entity is supposed to inside one of following entities : . 86F00
FIRST FLOOR PLAN W2 Entity is supposed to inside one of following entities : . 86F02

Failed AccessoryUse
Building Name Floor Name AccessoryUse Name Failed Information Entity Reference
A (DUTTA RESIDENCE) TERRACE FLOOR PLAN SOLAR HEATING SYSTEM Entity is supposed to inside one of following entities : . 86FF3
TERRACE FLOOR PLAN SOLAR HEATING SYSTEM Entity is supposed to inside one of following entities : . 86FF5

Failed GroundLevel
Building Name Floor Name GroundLevel Name Failed Information Entity Reference
A (DUTTA RESIDENCE) SECTION This entity should intersect with one of following entities : . 87100









BUNDU NAGAR PANCHAYAT