General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictRANCHI
AuthorityBUNDU NAGAR PANCHAYAT
Inward_NoBNPC/BP/0001/W11/2023
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageBundu
Taluka14
Architect Details
Architect NamePriyanka
License No.BNPC/ARC/0002/2021
Architect AddressManjhi Toli Bundu, PO- Bundu, PS-Bundu, Dist- Rnachi
Architect EmailIDmanjhipriyanka@gmail.com
Architect Mobile No7319055391
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No3511
NorthPlot No. - 3510
SouthRoad Width - 6
EastPlot No. - 3441
WestPlot No. - 3629
Owner's Details
NameSanjay Kumar
AddressSanjay Kumar S/O Jaydeo manjhi manjhi toli bundu near shiv mandir
Email IDsanjubliss75@gmail.com
Mobile No9480393057
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 1062.41
2 Plot area as per Document by Applicant 836.13
3 Physical area measured at site 836.13
4 Area as per Site Visit (Site Visit Report) 836.12
5Area as per Drawing 835.85

Area of Plot Considered : 835.85

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 835.85
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 835.85
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 789.07
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 46.78
46.78
Balance Plot Area 789.07

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 501.51
Proposed Coverage Area ( 28.14 % ) 235.21
Total Prop. Coverage Area ( 28.14 % ) 235.21
Balance coverage area ( 31.86 % ) 266.30
FAR CHECK
Perm. FAR Area ( 2.000 ) 1671.70
Total Perm. FAR area 1671.70
Residential FAR 500.05
Proposed FAR Area 500.05
Total Proposed FAR Area 500.05
Consumed FAR (Factor) 0.60
Balance FAR Area 1171.65
BUA CHECK
Total Proposed BuiltUp Area 529.70


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 6.1 6.10
Proposed Road Width as per Master Plan 5.1 -
Road Widening Width 0 -
Plot size (as per measurement) 836.12 835.85
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 835.85 OK
Plot Width Mt. - - 30.48 OK
Plot Depth Mt. - - 27.42 OK
Access Width Mt. - - 6.10 OK
Plot Frontage Mt. - - 7.50 OK
Coverage Area Sq.Mt. - 501.51 235.21 OK
FAR Area Sq.Mt. - 1671.70 500.05 OK
Consumed FAR Sq.Mt. - 2.00 0.60 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 41.79 46.78 OK
Common Plot Normal Open Space - Minimum Area Sq.Mt. - 46.78 OK
Normal Open Space - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 6 OK
A-1 (RESIDENTIAL G2) Front Margin... 6.1 M WIDE ROAD Mt. 4.00 - 12.35 OK
Rear Margin Mt. 2.50 - 2.52 OK
Side1 Margin Mt. 1.50 - 1.50 OK
Side2 Margin Mt. 1.50 - 10.24 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (RESIDENTIAL G2) Height Mt. 16.40 6.60 OK
A (RESIDENTIAL G2) First Floor - Height Mt. 2.75 - 3.30 OK
First Floor - Clear Height Mt. 2.75 - 3.20 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.95 OK
Ground Floor - Height Mt. 2.75 - 3.30 OK
Ground Floor - Clear Height Mt. 2.75 - 3.20 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.95 OK
Plinth - Height Mt. 0.45 - 0.60 OK
Plinth - Clear Height Mt. - - 0.60 OK
Plinth - Beam Clear Height Mt. - - 0.60 OK
A (RESIDENTIAL G2) Terrace Floor - Height Mt. - - 1.00 OK
Terrace Floor - Clear Height Mt. - - 1.00 OK
Terrace Floor - Beam Clear Height Mt. - - 1.00 OK
A (RESIDENTIAL G2) No. of Floors No. G + 4 2 OK
No. of Tenements No. - 1 OK
A (RESIDENTIAL G2) TYPICAL - 1 FLOOR PLAN - BALCONY - Width Mt. 1.20 1.20 OK
TYPICAL - 1 FLOOR PLAN - BALCONY - Width Mt. 1.20 1.20 OK
TYPICAL - 1 FLOOR PLAN - BALCONY-1 - Width Mt. 1.20 1.20 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.308 OK
STAIRCASE - Tread Width Mt. 0.225 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TYPICAL - 1 FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.308 OK
STAIRCASE - Tread Width Mt. 0.225 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN HEAD ROOM - Flight Width Mt. - 1.308 OK
HEAD ROOM - Tread Width Mt. - 0.254 OK
HEAD ROOM - Riser Height Mt. - - OK
HEAD ROOM - Riser No. On Flight No. - - OK
HEAD ROOM - Cabin Ht. Mt. 2.100 - 2.700 OK
SEPTIC TANK Area Sq.Mt. - - 1.25 OK
Width Mt. - - 0.78 OK
Depth Mt. - - 1.61 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 0.13 OK
Width Mt. - - 0.24 OK
Depth Mt. - - 0.55 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 1.56 OK
Width Mt. - - 0.36 OK
Depth Mt. - - 4.37 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 0.39 OK
Width Mt. - - 0.37 OK
Depth Mt. - - 1.05 OK
Height Mt. - - - OK
A (RESIDENTIAL G2) Rain Water Harvesting - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Bundu Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Bundu Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot ; ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 27-33 mt. and Plot width 27-33 mt., Margin required in Front shall be 4.0 mt., Rear 2.5 mt. and 1.5 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 15}
Balcony Projected balcony may be allowed with a widt of 1.2 mt. where the setback is more than 2.5 mt. {As per Rule No. 46.4 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SEPTIC TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)