No Image Found   

Detail Scrutiny Report

Bundu Nagar Panchayat

Version Number: 1.0.65  
Version Date: 16/10/2020 
Report Generated On: 06-01-2023 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictRANCHI
AuthorityBUNDU NAGAR PANCHAYAT
Inward_NoBNPC/BP/0002/W03/2022/ALT2
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentAddition or Alteration
Location of Development AreaNew Area
City Area/TPScheme NoNA
VillageBundu
Taluka14
Layout Sanction Date21/7/2022
Architect Details
Architect NameArun Ranjan
License No.BNPC/ARC/0002/2016
Architect Address303, Urmila Apartment, U B Lane Tharpakna
Architect EmailIDdotconsultant@gmail.com
Architect Mobile No9471550077
Plot Details
Plot Use Commercial
Plot SubUse Commercial Bldg
PlotNearbyReligiousStructure NA
Plot/SubPlot No1507,1509,1510,1511,1512
North -
South -
East -
West -
Owner's Details
NameANIL KUMAR JAISWAL
AddressASPATAL TOLI BUNDU PO PS BUNDU RANCHI
Email IDabhijaiswal18@gmail.com
Mobile No8709797396
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 898.64
2 Plot area as per Document by Applicant 891.25
3 Physical area measured at site 891.25
4 Area as per Site Visit (Site Visit Report) 891.25
5Area as per Drawing 891.25

Area of Plot Considered : 891.25

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyCommercial
Plot SubUse Commercial Bldg
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 891.25
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 891.25
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 812.39
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 78.86
78.86
Balance Plot Area 812.39

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 445.63
Proposed Coverage Area ( 39.95 % ) 356.03
Total Prop. Coverage Area ( 39.95 % ) 356.03
Balance coverage area ( 10.05 % ) 89.60
FAR CHECK
Perm. FAR Area ( 2.000 ) 1782.50
Total Perm. FAR area 1782.50
Commercial FAR 1662.56
Proposed FAR Area 1678.91
Total Proposed FAR Area 1678.91
Consumed FAR (Factor) 1.88
Balance FAR Area 103.59
BUA CHECK
Total Proposed BuiltUp Area 2092.46


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 7.64 7.64
Proposed Road Width as per Master Plan 7.5 -
Road Widening Width 0 -
Plot size (as per measurement) 891.25 891.25
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 44.56 78.86 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 78.86 0.00 0.00 - 2.96 - 77.22 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 8 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (BUILDING BG4) Commercial Commercial Bldg Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (BUILDING BG4) 19.25 14.85 14.85 14.85 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (BUILDING BG4) Fourth Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.60 OK
Third Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.75 OK
Second Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.75 OK
First Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.75 OK
Ground Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.75 OK
Basement Floor 2.40 - 2.50 2.40 - 2.40 2.10 - 2.25 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (BUILDING BG4) Terrace Floor - - 1.00 - - 1.00 - - 1.00 OK
   
   
[-] Basement Floor Check (Table 4a-3)
Building Name Floor Name Height of Basement Floor above GL Area Ventilation Area Status
Reqd Perm Prop Perm Prop Reqd Prop
A (BUILDING BG4) Basement Floor - - 1.20 - 356.03 - 0.00 OK


[-] Basement Floor Area Check
Building Name Area Status
Perm Prop
A (BUILDING BG4) - 356.03
Total - 356.03 OK

1 [-] Basement Margin Check
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
  A-1 (BUILDING BG4)   7.64 mt. Wide MainRoad 2.00 8.00 2.00 5.00 2.00 2.52 2.00 2.52 OK

    >
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (BUILDING BG4) G + 5 5 - 10 OK


[-] Basement Floor Number Check
Building Name No. of Basement Floor Status
Perm Prop
A (BUILDING BG4) 2 1 OK
 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
445.63 356.03 OK
50% 39.95%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (BUILDING BG4) - 356.03
  Total Prop. Coverage Area - 356.03
  Total Coverage Area 445.63 356.03

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Gross Built Up Area (Sq.mt.) Deductions From Gross BUA(Area in Sq.mt.) Total Built Up Area (Sq.mt.) Existing Built Up Area (Sq.mt.) Proposed Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Existing FAR Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In Existing FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Cutout Lift Balcony Parking Commercial Stair
A (BUILDING BG4) 1 2311.49 219.03 2092.46 1766.27 283.03 32.30 48.03 333.23 1440.39 222.18 16.34 1678.90 1678.90 10
Grand Total : 1 2311.49 219.03 2092.46 1766.27 283.03 32.30 48.03 333.23 1440.39 222.18 16.34 1678.90 1678.90 10


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (BUILDING BG4)
Proposed Built Up Area (Sq.mt.) Existing Built up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Existing FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total Existing Built up Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Existing FAR Area (Sq.mt.)
Basement Floor 55.99 300.04 16.34 0.00 55.99 300.04 16.34 0.00
Ground Floor 38.68 317.35 38.68 317.35 38.68 317.35 38.68 317.35
First Floor 54.02 320.01 54.02 313.55 54.02 320.01 54.02 313.55
Second Floor 39.89 350.15 39.89 343.69 39.89 350.15 39.89 343.69
Third Floor 40.27 351.25 40.27 344.79 40.27 351.25 40.27 344.79
Fourth Floor 54.18 127.47 49.31 121.01 54.18 127.47 49.31 121.01
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Total : 283.03 1766.27 238.51 1440.39 283.03 1766.27 238.51 1440.39


[-] UnitBUA Table for Building :A (BUILDING BG4)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type Entity Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN EXISTING UNIT-1 SHOP Existing 310.89 310.49 11 2
UNIT-1 SHOP Proposed 38.68 38.55 4
FIRST FLOOR PLAN EXISTING UNIT-2 SHOP Existing 313.55 313.23 10 2
UNIT-2 SHOP Proposed 54.02 53.77 5
SECOND FLOOR PLAN EXISTING UNIT-3 SHOP Existing 359.70 327.46 10 2
UNIT-3 SHOP Proposed 39.89 39.61 4
THIRD FLOOR PLAN EXISTING UNIT-4 OFFICE Existing 360.80 328.00 4 2
UNIT-4 OFFICE Proposed 50.00 40.12 3
FOURTH FLOOR PLAN EXISTING UNIT-5 OFFICE Existing 141.88 109.48 3 2
UNIT-5 OFFICE Proposed 54.18 43.54 3
Total: - - - 1723.60 1604.25 57 10


[-] Building :A (BUILDING BG4)
Floor Name Total Built Up Area (Sq.mt.) Existing Built Up Area (Sq.mt.) Proposed Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Existing FAR Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In Existing FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Balcony Parking Commercial Stair
Basement Floor 356.03 300.04 55.99 6.46 0.00 333.23 0.00 0.00 16.34 16.34 16.34 00
Ground Floor 356.03 317.35 38.68 0.00 0.00 0.00 317.35 38.68 0.00 356.03 356.03 02
First Floor 374.03 320.01 54.02 6.46 0.00 0.00 313.55 54.02 0.00 367.57 367.57 02
Second Floor 406.05 350.15 39.89 6.46 16.01 0.00 343.69 39.89 0.00 383.58 383.58 02
Third Floor 407.53 351.25 40.27 6.46 16.01 0.00 344.79 40.27 0.00 385.06 385.06 02
Fourth Floor 192.79 127.47 54.18 6.46 16.01 0.00 121.01 49.32 0.00 170.32 170.32 02
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 2092.46 1766.27 283.03 32.30 48.03 333.23 1440.39 222.18 16.34 1678.90 1678.90 10
Total Number of Same Buildings : 1
Total : 2092.46 1766.27 283.03 32.30 48.03 333.23 1440.39 222.18 16.34 1678.90 1678.90 10
[-] Table 4c-2

  FAR Area
Building FAR Area:1678.91
Existing FAR Area :0.00
Perm.
1782.50
Prop.
1678.91
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (BUILDING BG4) 7.64 mt. Wide MainRoad 8.00 8.00 5.00 5.00 2.50 2.52 2.50 2.50 OK






[-] Inner Building Details (Table 6)
   
   
[-] Balcony Details (Table 6c)

[-] For Building:A (BUILDING BG4)
Floor Name Balcony Name Width Status
Perm Prop
SECOND FLOOR PLAN BALCONY 1.20 1.20 OK
BALCONY 1.20 1.20 OK
BALCONY 1.20 1.20 OK
BALCONY 1.20 1.20 OK
THIRD FLOOR PLAN BALCONY 1.20 1.20 OK
BALCONY 1.20 1.20 OK
BALCONY 1.20 1.20 OK
BALCONY 1.20 1.20 OK
FOURTH FLOOR PLAN BALCONY 1.20 1.20 OK
BALCONY 1.20 1.20 OK
BALCONY 1.20 1.20 OK
BALCONY 1.20 1.20 OK



For PWork At Layout : 

No Balcony Found.

   
   
   
[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Number Of Strature Lift(s) Capacity Of Lift(s) Passanger Status
Prop Reqd Prop Reqd Prop Reqd Prop
A (BUILDING BG4) 14.85 2 2 - 0 12 12 OK

[-] Lift Check Table

[-] For Building :A (BUILDING BG4)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
BASEMENT FLOOR PLAN Lift 1.70 1.70 1.90 1.90 OK
Lift 1.70 1.70 1.90 1.90 OK
TERRACE FLOOR PLAN Lift Machine Room 1.70 1.70 1.90 1.90 OK
Lift Machine Room 1.70 1.70 1.90 1.90 OK

   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (BUILDING BG4) Commercial Commercial Bldg > 0 200 222.18 1 1 - - - -
> 0 200 222.18 - - - 1 3 -
Total : - - - - 1 7 - 3 11

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 7 87.50 OK
Total Car 1 12.50 7 87.50 OK
TwoWheeler - - 11 22.00 OK
Total TwoWheeler 3 6.00 11 22.00 OK
Other Parking - - - 223.73 OK
Total 18.50 355.23 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

[-] Driveway Parking Checks (Table 7d)
Building/Plot Name Floor Name Driveway Name Width Status
Reqd Perm Prop
A (BUILDING BG4) BASEMENT FLOOR PLAN 3.6 M WIDE DRIVEWAY 3.60 - 3.60 OK

   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (BUILDING BG4)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
BASEMENT FLOOR PLAN STAIRCASE 0.900 1.219 0.250 0.250 0.200 0.000 - 0 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.219 - 0.250 - 0.000 - 0 - - 2.400 OK

   
   
   

[-] Ramp Checks(Table 8b)
Ramp Name Width Depth Slope Status
Reqd Prop Reqd Prop Reqd Perm Prop
14.75 mt. long 1.30 mt. High 4.00 mt. Wide Natural Slope - 4.00 - 1.30 - - - OK
14.75 mt. long 1.30 mt. High 4.00 mt. Wide Natural Slope - 4.00 - 1.30 - - - OK


[-] Ramp Checks (Table 8b)
Building Name Floor Name No. Status
Reqd Prop
A (BUILDING BG4) BASEMENT FLOOR PLAN 1 1 OK
GROUND FLOOR PLAN - 1 OK
FIRST FLOOR PLAN - 1 OK
SECOND FLOOR PLAN - 1 OK
THIRD FLOOR PLAN - 1 OK
FOURTH FLOOR PLAN - 1 OK
TERRACE FLOOR PLAN - 1 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SUMP TANK - - 5.46 - - 1.70 - - 3.22 - - 0.00 OK
SUMP TANK - - 5.20 - - 1.70 - - 3.07 - - 0.00 OK
RAIN WATER HARVESTING - - 4.26 - - 1.74 - - 2.45 - - 0.00 OK
ENT.GATE - - 1.50 - - 0.30 - - 5.00 - - 0.00 OK
SOLAR HEATING SYSTEM - - 3.60 - - 1.28 - - 2.81 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (BUILDING BG4) Rain Water Harvesting 1 - 1 OK
Entrance Gate 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (BUILDING BG4)


[-] Floor:BASEMENT FLOOR PLAN



No Room Found.


[-] Floor:GROUND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:FIRST FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:SECOND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:THIRD FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:FOURTH FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 891.25 OK
  Plot Width - 19.26 OK
  Plot Depth - 46.27 OK
  Access Width 6.10 7.64 OK
  Plot Frontage - 16.53 OK
  Coverage Area 445.63 356.03 OK
  FAR Area
Bldg. FAR Area : 1678.91
Sanctioned FAR Area :0.00
1782.50 1678.91 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In New Area, for Non-Residential Building on abutting roadwidth 7.5(25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Bundu Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In New Area, for Non-Residential Building on abutting roadwidth 7.5(25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Bundu Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Non-highrise Commercial Building upto 16.4 mt. Ht. having Plot Depth 45 mt. or above and Plot width 15-21 mt., Margin required in Front shall be 8.0 mt., Rear 5.0 mt. and 2.5 mt. shall be provided on both side. {As per Rule No. 36 Table 10 & 11}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 2 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Building Height For new area, on Road width 7.5-9.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 19.25 mt. {As per Rule No. 39.1 Table 16}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Below GL Floor Height -,
Basement Floor No. Maximum two basements/cellars may be permitted to be constructed for the plot size above 750 sq.mt. leaving the prescribed set back/open space applicable to the building {As per Rule No. 48}
Floor Number For new area location,on Road width 7.5-9.1 mt. only G+5 floors shall be allowed {As per Rule No. 39.1 Table 16 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Balcony Projected balcony may be allowed with a widt of 1.2 mt. where the setback is more than 2.5 mt. {As per Rule No. 46.4 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Non-Residential Building, Minimum number of lifts to be 2 for all non-residential building above ground + 2 and the minimum capacity shall be 6 persons per floor. {As per Rule No. 49.2.3 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. (1) For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
(2) -
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)