-
No Image Found   

Detail Scrutiny Report

Chakulia Nagar Panchayat

Version Number: 1.0.49  
Version Date: 22/06/2020 
Report Generated On: 16-10-2020 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityCHAKULIA NAGAR PANCHAYAT
Inward_NoCNPC/BP/0014/ward8/2020
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageKankrisole
Taluka16
Architect Details
Architect NameL K SUMAN
License No.CNPC/ENG/0002/2018
Architect AddressSHOP NO.-01, 2ND FLOOR BASANT TAKIES COMPLEX SAKCHI, JAMSHEDPUR
Architect EmailIDlksumanoffice@gmail.com
Architect Mobile No9835131161
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No276
NorthPlot No. - 276
SouthPlot No. - 276
EastPlot No. - 275
WestRoad Width - 3.6
Owner's Details
NameSri. Bishwanath Ghosh
AddressWard-8, Kankrisole Chakulia
Email IDbishwanathchakulia1968@gmail.com
Mobile No9204582580
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 340.00
2 Plot area as per Document by Applicant 340.00
3 Physical area measured at site 339.70
4 Area as per Site Visit (Site Visit Report) 339.80
5Area as per Drawing 339.46

Area of Plot Considered : 339.46

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPROPOSED BUILDING
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 339.46
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 339.46
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 313.57
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 25.89
25.89
Balance Plot Area 313.57

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 203.68
Proposed Coverage Area ( 59.96 % ) 203.54
Total Prop. Coverage Area ( 59.96 % ) 203.54
Balance coverage area ( 0.04 % ) 0.14
FAR CHECK
Perm. FAR Area ( 1.50 ) 509.19
Total Perm. FAR area 509.19
Residential FAR 499.43
Proposed FAR Area 499.43
Total Proposed FAR Area 499.43
Consumed FAR (Factor) 1.47
Balance FAR Area 9.76
BUA CHECK
Total Proposed BuiltUp Area 499.44


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 3.6 3.60
Proposed Road Width as per Master Plan 3.6 -
Road Widening Width 0 -
Plot size (as per measurement) 339.8 339.46
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 16.97 25.89 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 25.89 0.00 0.00 - 2.27 - 90.00 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 4 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (BISHWANATH GHOSH) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (BISHWANATH GHOSH) 10.00 9.38 9.38 9.99 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (BISHWANATH GHOSH) Second Floor 2.75 - 2.88 2.75 - 2.75 2.40 - 2.52 OK
First Floor 2.75 - 3.15 2.75 - 3.03 2.40 - 2.80 OK
Ground Floor 2.75 - 3.35 2.75 - 3.23 2.40 - 3.00 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (BISHWANATH GHOSH) Terrace Floor 1.00 1.20 1.01 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (BISHWANATH GHOSH) G + 2 3 - 2 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
203.68 203.54 OK
60% 59.96%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (BISHWANATH GHOSH) - 203.54
  Total Prop. Coverage Area - 203.54
  Total Coverage Area 203.68 203.54

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
A (BISHWANATH GHOSH) 1 499.44 499.44 499.44 499.44 02
Grand Total : 1 499.44 499.44 499.44 499.44 02


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (BISHWANATH GHOSH)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 203.54 203.54 203.54 203.54
First Floor 203.54 203.54 203.54 203.54
Second Floor 92.36 92.36 92.36 92.36
Terrace Floor 0.00 0.00 0.00 0.00
Total : 499.44 499.44 499.44 499.44


[-] UnitBUA Table for Building :A (BISHWANATH GHOSH)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN UNIT A FLAT 203.54 201.90 17 1
FIRST FLOOR PLAN SPLIT B FLAT 295.89 293.25 17 1
SECOND FLOOR PLAN SPLIT B FLAT 0.00 0.00 4 0
Total: - - 499.43 495.15 38 2


[-] Building :A (BISHWANATH GHOSH)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
Ground Floor 203.54 203.54 203.54 203.54 01
First Floor 203.54 203.54 203.54 203.54 01
Second Floor 92.36 92.36 92.36 92.36 00
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 499.44 499.44 499.44 499.44 02
Total Number of Same Buildings : 1
Total : 499.44 499.44 499.44 499.44 02
[-] Table 4c-2

  FAR Area
Building FAR Area:499.43
Existing FAR Area :0.00
Perm.
509.19
Prop.
499.43
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (BISHWANATH GHOSH) 3.6 M WIDE ROAD 4.00 4.64 2.50 3.01 0.90 1.02 0.90 1.10 OK






[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car Visitors Car
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (BISHWANATH GHOSH) Residential Bungalow/ Dwelling / Non Apartment > 0 1 2.00 1 2 - - - -
> 0 1 2.00 - - - 1 1 -
Total : - - - - 2 2 - 1 1

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 2 25.00 OK
Total Car 2 25.00 2 25.00 OK
Visitor's Car Parking - - 1 12.50 OK
Total Visitor Parking 1 12.50 1 12.50 OK
Total 37.50 37.50 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

Driveway Parking Checks (Table 7d)
Plot Level Parking Driveway is as per the Rules
Floor Level Parking Driveway is as per the Rules
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (BISHWANATH GHOSH)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.900 1.067 0.250 0.254 0.200 0.152 - 11 - - 0.000 OK
FIRST FLOOR PLAN STAIRCASE 0.900 1.067 0.250 0.254 0.200 0.150 - 11 - - 0.000 OK
SECOND FLOOR PLAN STAIRCASE 0.900 1.067 0.250 0.254 0.200 0.151 - 11 - - 0.000 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
RAIN WATER HARVESTING - - 1.26 - - 0.89 - - 1.41 - - 0.00 OK
SOLAR HEATING SYSTEM - - 6.69 - - 1.83 - - 3.66 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (BISHWANATH GHOSH) Rain Water Harvesting 1 - 1 OK
Solar Water Heating System 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (BISHWANATH GHOSH)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:FIRST FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:SECOND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 339.46 OK
  Plot Width - 11.59 OK
  Plot Depth - 29.29 OK
  Access Width - 3.60 OK
  Plot Frontage - 11.58 OK
  Coverage Area 203.68 203.54 OK
  FAR Area
Bldg. FAR Area : 499.43
Sanctioned FAR Area :0.00
509.19 499.43 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For CHAKULIA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For CHAKULIA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 27-33 mt. and Plot width 10-15 mt., Margin required in Front shall be 4.0 mt., Rear 2.5 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) -
(4) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) For Individual residential buildings having more than 150 sq m. plinth area, Provisions of Solar Water Heating System shall be done Solar Water Heating System
Building Level (Rooms)