No Image Found   

Failed List Report

Chakulia Nagar Panchayat

Version Number: 1.0.46  
Version Date: 22/06/2020 
Report Generated On: 27-08-2020 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityCHAKULIA NAGAR PANCHAYAT
Inward_NoCNPC/BP/0011/W02/2020
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageChakulia
Taluka16
Architect Details
Architect NameL K SUMAN
License No.CNPC/ENG/0002/2018
Architect AddressSHOP NO.-01, 2ND FLOOR BASANT TAKIES COMPLEX SAKCHI, JAMSHEDPUR
Architect EmailIDlksumanoffice@gmail.com
Architect Mobile No9835131161
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No336, 337
NorthRoad Width - 6.2
SouthSurvey No. - OTHER PLOT
EastSurvey No. - Other plot
WestSurvey No. - other plot
Owner's Details
NameSri. Bablu Hansda
AddressWard-2, Po+Ps- Chakulia, Chakulia
Email IDbabluhansda2390@gmail.com
Mobile No6206866477
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 307.23
2 Plot area as per Document by Applicant 299.68
3 Physical area measured at site 299.68
4 Area as per Site Visit (Site Visit Report) 299.69
5Area as per Drawing 174.12

Area of Plot Considered : 174.12

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPROPOSED
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 174.12
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 174.12
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 142.10
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 32.02
32.02
Balance Plot Area 142.10

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 121.88
Proposed Coverage Area ( 35.67 % ) 62.10
Total Prop. Coverage Area ( 35.67 % ) 62.10
Balance coverage area ( 34.33 % ) 59.78
FAR CHECK
Perm. FAR Area ( 2.00 ) 348.24
Total Perm. FAR area 348.24
Residential FAR 124.20
Proposed FAR Area 124.20
Total Proposed FAR Area 124.20
Consumed FAR (Factor) 0.71
Balance FAR Area 224.04
BUA CHECK
Total Proposed BuiltUp Area 124.20


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 100 meter and upto 250 meter -
Existing Road Width 6.2 6.20
Proposed Road Width as per Master Plan 6.2 -
Road Widening Width 0 -
Plot size (as per measurement) 299.69 174.12
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK
   



[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For CHAKULIA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For CHAKULIA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For narrow plots,the setbacks on sides may be compensated in front and rear setbacks so as to ensure that the overall aggregate setbacks are maintained in the site, subject to maintaining a minimum of side setback of 1m in case of buildings of height up to 10.0 mt.
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) -
(4) No need to check distance from Building SOLAR HEATING SYSTEM
Building Level (Rooms)