General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictGARHWA
AuthorityGARHWA NAGAR PARISHAD
Inward_NoGNPC/BP/0009/W09/2017
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageSahijana
Taluka30
Architect Details
Architect NameRESHAN ALI
License No.GNPC/ENG/0005/2017
Architect AddressAT:- WARSI COMPLEX, KUTTCHERY ROAD, NEAR H.K PETROL PUMP
Architect EmailIDarchitectakhtar@gmail.com
Architect Mobile No9835159686
Plot Details
Plot Use Residential
Plot SubUse Lodging
PlotNearbyReligiousStructure NA
Plot/SubPlot No703
NorthRoad Width - 2.4
SouthPlot No. - 693
EastPlot No. - 703
WestPlot No. - 703
Owner's Details
NameSRI ANUJ KUMAR SINGH
AddressAT SAHIJNA, GARHWA, P.S:- GARHWA, DIST:- GARHWA, ( JHARKHAND)
Email IDluckyahmed887@gmail.com
Mobile No7765054116
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 123.00
2 Plot area as per Document by Applicant 122.22
3 Physical area measured at site 122.22
4 Area as per Site Visit (Site Visit Report) 122.22
5Area as per Drawing 122.22

Area of Plot Considered : 122.22

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Lodging
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 122.22
Deduction from Gross Plot area
- Surrender Free of Cost 19.64
19.64
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 102.58
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 88.26
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 19.64
- Common Plot 14.31
33.96
Balance Plot Area 88.26

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 71.80
Proposed Coverage Area ( 50.09 % ) 51.38
Total Prop. Coverage Area ( 50.09 % ) 51.38
Balance coverage area ( 19.91 % ) 20.42
FAR CHECK
Perm. FAR Area ( 1.20 ) 146.66
Total Perm. FAR area 146.66
Residential FAR 51.38
Proposed FAR Area 51.38
Total Proposed FAR Area 51.38
Consumed FAR (Factor) 0.42
Balance FAR Area 95.28
BUA CHECK
Total Proposed BuiltUp Area 51.38


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 100 meter and upto 250 meter -
Existing Road Width 2.4 2.40
Proposed Road Width as per Master Plan 5.1 -
Road Widening Width 1.35 1.35
Plot size (as per measurement) 122.22 122.22


Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 102.58 OK
Plot Width Sq.Mt. - - 14.55 OK
Plot Depth Sq.Mt. - - 7.05 OK
Access Width Sq.Mt. - - 2.40 OK
Plot Frontage Sq.Mt. - - 14.55 OK
Coverage Area Sq.Mt. - 71.80 51.38 OK
FAR Area Sq.Mt. - 146.66 51.38 OK
Consumed FAR Sq.Mt. - 1.20 0.42 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 5.13 14.31 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 14.31 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 1.37 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 2 7 OK
A-1 (BUILDING) Front Margin... ROAD WIDENING AREA(SURRENDERED FREE OF COST) Mt. 1.50 - 1.50 OK
Rear Margin Mt. 0.90 - 0.90 OK
Side1 Margin Mt. 0.90 - 0.90 OK
Side2 Margin Mt. 0.90 - 2.60 OK

Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (BUILDING) Ground Floor - Height Mt. 2.75 - 3.90 OK
A (BUILDING) Terrace Floor - Height Mt. 1.00 1.20 1.05 OK
A (BUILDING) No. of Floors No. P + 1 1 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 0.900 OK
STAIRCASE - Tread Width Mt. 0.225 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.186 OK
STAIRCASE - Riser No. On Flight No. - 20 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 0.900 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. 2.100 - 3.000 OK
SUMP TANK Area Sq.Mt. - - 4.20 OK
Width Mt. - - 1.83 OK
Depth Mt. - - 2.30 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 3.06 OK
Width Mt. - - 1.08 OK
Depth Mt. - - 2.83 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.40 OK
Width Mt. - - 0.14 OK
Depth Mt. - - 2.89 OK
Height Mt. - - - OK
All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth less than 3.60 mt., the Floor Area Ratio-FAR shall be 1.2 {As per Rule No.39, Table 15, Note i}
(2) For GARHWA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth less than 3.60 mt., the Floor Area Ratio-FAR shall be 1.2 {As per Rule No.39, Table 15, Note i}
(2) For GARHWA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth upto 10.0 mt. and Plot width 10-15 mt., Margin required in Front shall be 1.5 mt., Rear 0.9 mt. and and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width upto 3.6 mt. only Stilt + 1 floors shall be allowed {As per Rule No. 39.1 Note 1}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
Building Level (Rooms)