No Image Found

Check List Report

Garhwa Nagar Panchayat

Version Number: 1.0.27
Version Date: 18/05/2018
Report Generated On: 09-06-2018

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictGARHWA
AuthorityGARHWA NAGAR PARISHAD
Inward_NoGNPC/BP/0035/W07/2018
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillagePipra Kala
Taluka30
Architect Details
Architect NameRESHAN ALI
License No.GNPC/ENG/0005/2017
Architect AddressAT:- WARSI COMPLEX, KUTTCHERY ROAD, NEAR H.K PETROL PUMP
Architect EmailIDarchitectakhtar@gmail.com
Architect Mobile No9835159686
Plot Details
Plot Use Residential
Plot SubUse ResiComm Bldg
PlotNearbyReligiousStructure NA
Plot/SubPlot No62
NorthPlot No. - 62
SouthPlot No. - 62
EastRoad Width - 13.7
WestPlot No. - 62
Owner's Details
NameSHEELA CHOUBEY
AddressAT PIPRA KALA, GARHWA, DISTT GARHWA JHARKHAND
Email IDluckyahmed887@gmail.com
Mobile No7631092224
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 283.37
2 Plot area as per Document by Applicant 283.37
3 Physical area measured at site 283.37
4 Area as per Site Visit (Site Visit Report) 283.37
5Area as per Drawing 283.37

Area of Plot Considered : 283.37

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse ResiComm Bldg
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 283.37
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 283.37
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 257.80
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 25.57
25.57
Balance Plot Area 257.80

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 170.02
Proposed Coverage Area ( 37.70 % ) 106.82
Total Prop. Coverage Area ( 37.7 % ) 106.82
Balance coverage area ( 22.30 % ) 63.20
FAR CHECK
Perm. FAR Area ( 2.00 ) 566.74
Total Perm. FAR area 566.74
Residential FAR 195.70
Commercial FAR 204.67
Proposed FAR Area 410.10
Total Proposed FAR Area 410.10
Consumed FAR (Factor) 1.45
Balance FAR Area 156.64
BUA CHECK
Total Proposed BuiltUp Area 534.06


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 13.7 13.70
Proposed Road Width as per Master Plan 13.7 -
Road Widening Width 0 -
Plot size (as per measurement) 283.37 283.37


Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 283.37 OK
Plot Width Sq.Mt. - - 12.80 OK
Plot Depth Sq.Mt. - - 22.14 OK
Access Width Sq.Mt. - - 13.70 OK
Plot Frontage Sq.Mt. - - 12.80 OK
Coverage Area Sq.Mt. - 170.02 106.82 OK
FAR Area Sq.Mt. - 566.74 410.10 OK
Consumed FAR Sq.Mt. - 2.00 1.45 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 28.34 25.57 Failed
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 25.57 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 3.82 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 8 OK
Car In Area Sq.Mt. - - 62.50 OK
Total Car In Area Sq.Mt. 187.50 - 62.50 Failed
Visitor's Car Parking In Area Sq.Mt. 100.00 - 0.00 Failed
TwoWheeler In Area Sq.Mt. 28.00 - 28.00 OK
Other Parking In Area Sq.Mt. - - 46.71 OK
A-1 (BUILDING) Front Margin... 13.7 M WIDE MAINROAD Access Road Mt. 6.00 - 6.00 OK
Rear Margin Mt. 4.00 - 4.00 OK
Side1 Margin Mt. 2.00 - 2.00 OK
Side2 Margin Mt. 2.00 - 2.00 OK

Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (BUILDING) Height Mt. 26.55 12.92 OK
A (BUILDING) Third Floor - Height Mt. 2.75 - 2.85 OK
Second Floor - Height Mt. 2.75 - 2.85 OK
First Floor - Height Mt. 2.75 - 2.85 OK
Ground Floor - Height Mt. 2.75 - 3.00 OK
Parking Floor - Height Mt. - - 3.30 OK
A (BUILDING) Terrace Floor - Height Mt. 1.00 1.20 1.00 OK
A (BUILDING) No. of Floors No. - 5 OK
No. of Tenements No. - 2 OK
A (BUILDING) Number Of Lift(s) No. 2 2 OK
A (BUILDING) PARKING FLOOR PLAN - PASSENGER LIFT for 6 Persons - Width Mt. 1.70 1.80 OK
PARKING FLOOR PLAN - PASSENGER LIFT for 6 Persons - Depth Mt. 1.90 2.48 OK
PARKING FLOOR PLAN - PASSENGER LIFT for 6 Persons - Width Mt. 1.70 1.80 OK
PARKING FLOOR PLAN - PASSENGER LIFT for 6 Persons - Depth Mt. 1.90 2.50 OK
GROUND FLOOR PLAN - PASSENGER LIFT for 6 Persons - Width Mt. 1.70 1.80 OK
GROUND FLOOR PLAN - PASSENGER LIFT for 6 Persons - Depth Mt. 1.90 2.48 OK
GROUND FLOOR PLAN - PASSENGER LIFT for 6 Persons - Width Mt. 1.70 1.80 OK
GROUND FLOOR PLAN - PASSENGER LIFT for 6 Persons - Depth Mt. 1.90 2.50 OK
FIRST FLOOR PLAN - PASSENGER LIFT for 6 Persons - Width Mt. 1.70 1.80 OK
FIRST FLOOR PLAN - PASSENGER LIFT for 6 Persons - Depth Mt. 1.90 2.48 OK
FIRST FLOOR PLAN - PASSENGER LIFT for 6 Persons - Width Mt. 1.70 1.80 OK
FIRST FLOOR PLAN - PASSENGER LIFT for 6 Persons - Depth Mt. 1.90 2.50 OK
SECOND FLOOR PLAN - PASSENGER LIFT for 6 Persons - Width Mt. 1.70 1.80 OK
SECOND FLOOR PLAN - PASSENGER LIFT for 6 Persons - Depth Mt. 1.90 2.48 OK
SECOND FLOOR PLAN - PASSENGER LIFT for 6 Persons - Width Mt. 1.70 1.80 OK
SECOND FLOOR PLAN - PASSENGER LIFT for 6 Persons - Depth Mt. 1.90 2.50 OK
THIRD FLOOR PLAN - PASSENGER LIFT for 6 Persons - Width Mt. 1.70 1.80 OK
THIRD FLOOR PLAN - PASSENGER LIFT for 6 Persons - Depth Mt. 1.90 2.48 OK
THIRD FLOOR PLAN - PASSENGER LIFT for 6 Persons - Width Mt. 1.70 1.80 OK
THIRD FLOOR PLAN - PASSENGER LIFT for 6 Persons - Depth Mt. 1.90 2.50 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.80 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 2.48 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.80 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 2.50 OK
PARKING FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.135 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.174 OK
STAIRCASE - Riser No. On Flight No. - 9 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.135 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.158 OK
STAIRCASE - Riser No. On Flight No. - 9 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.135 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 9 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
SECOND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.135 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 9 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
THIRD FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.135 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 9 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.135 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 3.000 OK
SUMP TANK Area Sq.Mt. - - 7.92 OK
Width Mt. - - 1.84 OK
Depth Mt. - - 4.31 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 3.61 OK
Width Mt. - - 1.57 OK
Depth Mt. - - 2.30 OK
Height Mt. - - - OK
PLOT 8.60 mt. long 1.50 mt. High 3.36 mt. Wide Car Ramp - Width Mt. 3.30 3.36 OK
8.60 mt. long 1.50 mt. High 3.36 mt. Wide Car Ramp - Depth Mt. 1.00 1.50 OK
8.60 mt. long 1.50 mt. High 3.36 mt. Wide Car Ramp - Slope Ratio 1.00 : 7.00 - 01 : 06 Failed
Ramp No. A (BUILDING) - PARKING FLOOR PLAN - No. No. 1 1 OK
All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For GARHWA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For GARHWA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Commercial Building upto 16.4 mt. Ht. having Plot Depth 21-27 mt. and Plot width 10-15 mt., Margin required in Front shall be 6.0 mt., Rear 4.0 mt. and 2.0 mt. shall be provided on both side. {As per Rule No. 36 Table 10 & 11}
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) Stilt floor is of minimum height of 2.4 meter. From floor to ceiling and not less than 2.10 mt. from the soffit of beams
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Non-Residential Building, Minimum number of lifts to be 2 for all non-residential building above ground + 2 and the minimum capacity shall be 6 persons per floor. {As per Rule No. 49.2.3 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp For parking spaces in basements and upper storey of parking floors,if car parking is less then 40, one ramp of minimum of 3.30m width if it is strait and 4.5m width if it is curved at any point and with minimum slope gradient of 1:7 for depth up to 1.8m and 1:10 for more than 1.8m depth shall be provided {As per Rule No. 41.8 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017} ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
Building Level (Rooms)