No Image Found

Check List Report

Garhwa Nagar Panchayat

Version Number: 1.0.26
Version Date: 10/05/2018
Report Generated On: 17-05-2018

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictGARHWA
AuthorityGARHWA NAGAR PARISHAD
Inward_NoGNPC/BP/0048/W07/2018
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillagePipra Kala
Taluka30
Architect Details
Architect NamePRADEEP KUNTAL KUNTAL
License No.GNPC/ARC/0007/2017
Architect AddressC/O ALOK KUMAR TIWARI,NEAR SHANTINIWAS SCHOOL ,SHRI RAM NAGAR ,CHINIYA ROAD,GARHWA
Architect EmailIDm.tiwary8@gmail.com
Architect Mobile No7782927526
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No76/264
NorthRoad Width - 3.05
SouthPlot No. - 76/264
EastPlot No. - 76/264
WestPlot No. - 76/264
Owner's Details
NameSHRI DINESH CHAND MISHRA
AddressPIPRAKALA GARHWA
Email IDalok.kumar462@gmail.com
Mobile No8409769350
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 100.90
2 Plot area as per Document by Applicant 100.90
3 Physical area measured at site 100.90
4 Area as per Site Visit (Site Visit Report) 100.90
5Area as per Drawing 100.90

Area of Plot Considered : 100.90

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 100.90
Deduction from Gross Plot area
- Surrender Free of Cost 7.06
7.06
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 93.84
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 77.86
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 7.06
- Common Plot 15.97
23.04
Balance Plot Area 77.86

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 65.69
Proposed Coverage Area ( 64.89 % ) 60.89
Total Prop. Coverage Area ( 64.89 % ) 60.89
Balance coverage area ( 5.12 % ) 4.80
FAR CHECK
Perm. FAR Area ( 1.20 ) 121.08
Total Perm. FAR area 121.08
Residential FAR 60.89
Proposed FAR Area 60.89
Total Proposed FAR Area 60.89
Consumed FAR (Factor) 0.60
Balance FAR Area 60.19
BUA CHECK
Total Proposed BuiltUp Area 60.89


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 3.05 3.05
Proposed Road Width as per Master Plan 3.05 -
Road Widening Width 1.05 1.05
Plot size (as per measurement) 100.9 100.90


Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 93.84 OK
Plot Width Sq.Mt. - - 6.73 OK
Plot Depth Sq.Mt. - - 13.95 OK
Access Width Sq.Mt. - - 3.05 OK
Plot Frontage Sq.Mt. - - 6.73 OK
Coverage Area Sq.Mt. - 65.69 60.89 OK
FAR Area Sq.Mt. - 121.08 60.89 OK
Consumed FAR Sq.Mt. - 1.20 0.60 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 4.69 15.97 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 15.97 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 1.37 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 2 5 OK
A-1 (BUILDING) Front Margin... ROAD WIDENING AREA (SURRENDERED FREE OF COST) Mt. - - 1000.10 OK
Rear Margin Mt. - - OK
Side1 Margin Mt. - - - OK
Side2 Margin Mt. - - - OK
A-1 (BUILDING) BldgLine for 3.05 MT WD MAINROAD Access Road Mt. 0.27 3.05 OK
A-1 (BUILDING) ResvRoad Width Check for... 3.05 MT WD MAINROAD Access Road Mt. 0.27 1.05 OK

Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (BUILDING) Ground Floor - Height Mt. 2.75 - 3.90 OK
A (BUILDING) Terrace Floor - Height Mt. 1.00 1.20 1.00 OK
A (BUILDING) No. of Floors No. G + 1 1 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.000 OK
STAIRCASE - Tread Width Mt. 0.225 0.230 OK
STAIRCASE - Riser Height Mt. 0.200 0.162 OK
STAIRCASE - Riser No. On Flight No. - 12 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.000 OK
STAIRCASE - Tread Width Mt. - 0.230 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. 2.100 - 2.400 OK
SUMP TANK Area Sq.Mt. - - 3.91 OK
Width Mt. - - 1.59 OK
Depth Mt. - - 2.46 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 3.86 OK
Width Mt. - - 1.57 OK
Depth Mt. - - 2.46 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.11 OK
Width Mt. - - 0.09 OK
Depth Mt. - - 1.24 OK
Height Mt. - - - OK
All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth less than 3.60 mt., the Floor Area Ratio-FAR shall be 1.2 {As per Rule No.39, Table 15, Note i}
(2) For GARHWA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth less than 3.60 mt., the Floor Area Ratio-FAR shall be 1.2 {As per Rule No.39, Table 15, Note i}
(2) For GARHWA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Building Line Check The min. width of Road for length of Road upto 50 mt. shall be 3.6 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road upto 50 mt. shall be 3.6 mt. {As per Rule No. 34 Table No. 6}
Building Level
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width upto 3.6 mt. only G+1 floors shall be allowed {As per Rule No. 39.1 Note 1}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
Building Level (Rooms)