No Image Found

Check List Report

Garhwa Nagar Panchayat

Version Number: 1.0.28
Version Date: 30/06/2018
Report Generated On: 28-07-2018

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictGARHWA
AuthorityGARHWA NAGAR PARISHAD
Inward_NoGNPC/BP/0068/W16/2018
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillagePipra Kala
Taluka30
Architect Details
Architect NameRESHAN ALI
License No.GNPC/ENG/0005/2017
Architect AddressAT:- WARSI COMPLEX, KUTTCHERY ROAD, NEAR H.K PETROL PUMP
Architect EmailIDarchitectakhtar@gmail.com
Architect Mobile No9835159686
Plot Details
Plot Use Commercial
Plot SubUse Shop
PlotNearbyReligiousStructure NA
Plot/SubPlot No31
NorthPlot No. - 31
SouthRoad Width - 30
EastPlot No. - 31
WestPlot No. - 31
Owner's Details
NameHANIF KHAN
AddressAT:- MAIN ROAD, PIPRA KALA , PO+PS:-GARHWA, DIST:- GARHWA(JH.)
Email IDluckyahmed887@gmail.com
Mobile No7992407749
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 521.06
2 Plot area as per Document by Applicant 521.06
3 Physical area measured at site 521.06
4 Area as per Site Visit (Site Visit Report) 521.06
5Area as per Drawing 521.06

Area of Plot Considered : 521.06

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyCommercial
Plot SubUse Shop
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 521.06
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 521.06
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 402.55
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 118.50
118.50
Balance Plot Area 402.55

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 260.53
Proposed Coverage Area ( 36.89 % ) 192.20
Total Prop. Coverage Area ( 36.89 % ) 192.20
Balance coverage area ( 13.11 % ) 68.33
FAR CHECK
Perm. FAR Area ( 2.00 ) 1042.12
Total Perm. FAR area 1042.12
Commercial FAR 424.39
Proposed FAR Area 434.12
Total Proposed FAR Area 434.12
Consumed FAR (Factor) 0.83
Balance FAR Area 608.00
BUA CHECK
Total Proposed BuiltUp Area 656.60


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 30 30.00
Proposed Road Width as per Master Plan 30 -
Road Widening Width 0 -
Plot size (as per measurement) 521.06 521.06


Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 521.06 OK
Plot Width Sq.Mt. - - 15.54 OK
Plot Depth Sq.Mt. - - 33.53 OK
Access Width Sq.Mt. - - 30.00 OK
Plot Frontage Sq.Mt. - - 15.54 OK
Coverage Area Sq.Mt. - 260.53 192.20 OK
FAR Area Sq.Mt. - 1042.12 434.12 OK
Consumed FAR Sq.Mt. - 2.00 0.83 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 26.05 118.50 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 50.94 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 2.33 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Cover (Plantation) - Minimum Area Sq.Mt. - 67.57 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 4.39 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 27 OK
Car In Area Sq.Mt. - - 162.50 OK
Total Car In Area Sq.Mt. 75.00 - 162.50 OK
TwoWheeler In Area Sq.Mt. 34.00 - 0.00 Failed
Other Parking In Area Sq.Mt. - - 69.97 OK
A-1 (BUILDING) Front Margin... 30 M WIDE MAINROAD Access Road Mt. 7.00 - 7.00 OK
Rear Margin Mt. 4.50 - 4.50 OK
Side1 Margin Mt. 2.50 - 2.50 OK
Side2 Margin Mt. 2.50 - 2.50 OK

Building Related Details
Name Description Unit Reqd Perm Proposed Status
PARKING FLOOR PLAN Required Floor Level Parking Driveway of 3.60 mt. distance is not Provided at PARKING FLOOR PLAN In A (BUILDING). Mt. - - - Failed
A (BUILDING) Height Mt. 52.00 7.22 OK
A (BUILDING) First Floor - Height Mt. 2.75 - 2.85 OK
Ground Floor - Height Mt. 2.75 - 3.00 OK
Parking Floor - Height Mt. - - 3.30 OK
A (BUILDING) Terrace Floor - Height Mt. 1.00 1.20 1.00 OK
A (BUILDING) No. of Floors No. - 3 OK
No. of Tenements No. - - OK
PARKING FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.135 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.174 OK
STAIRCASE - Riser No. On Flight No. - 9 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.135 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.158 OK
STAIRCASE - Riser No. On Flight No. - 9 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.135 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 9 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.135 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 3.000 OK
SUMP TANK Area Sq.Mt. - - 12.05 OK
Width Mt. - - 3.00 OK
Depth Mt. - - 4.02 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 6.07 OK
Width Mt. - - 2.07 OK
Depth Mt. - - 2.93 OK
Height Mt. - - - OK
A (BUILDING) Rain Water Harvesting - No No. 1 - 1 OK
PLOT 10.00 mt. long 1.50 mt. High 4.00 mt. Wide Natural Slope - Width Mt. 3.30 4.00 OK
10.00 mt. long 1.50 mt. High 4.00 mt. Wide Natural Slope - Depth Mt. 1.00 1.50 OK
10.00 mt. long 1.50 mt. High 4.00 mt. Wide Natural Slope - Slope Ratio 1.00 : 7.00 - 01 : 07 OK
Ramp No. A (BUILDING) - PARKING FLOOR PLAN - No. No. 1 1 OK
All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 3.0 {As per Rule No.39, Table 15}
(2) For GARHWA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 3.0 {As per Rule No.39, Table 15}
(2) For GARHWA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) ; In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
(3) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(4) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Commercial Building upto 16.4 mt. Ht. having Plot Depth 33-39 mt. and Plot width 15-21 mt., Margin required in Front shall be 7.0 mt., Rear 4.5 mt. and 2.5 mt. shall be provided on both side. {As per Rule No. 36 Table 10 & 11}
Building Level
Floor Parking DriveWay Check The minimum width of the drive way meant exclusively for 2 wheelers should be 3.0 mt {As per Rule No. 41.2}
Building Height For old area, on Road width above 18.30 mt., No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) Stilt floor is of minimum height of 2.4 meter. From floor to ceiling and not less than 2.10 mt. from the soffit of beams
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 18.30 mt. and above, No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp For parking spaces in basements and upper storey of parking floors,if car parking is less then 40, one ramp of minimum of 3.30m width if it is strait and 4.5m width if it is curved at any point and with minimum slope gradient of 1:7 for depth up to 1.8m and 1:10 for more than 1.8m depth shall be provided {As per Rule No. 41.8 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017} ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
Accessory Use Number Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
Building Level (Rooms)