General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictGARHWA
AuthorityGARHWA NAGAR PARISHAD
Inward_NoGNPC/BP/0064/W08/2018
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageSahijana
Taluka30
Architect Details
Architect NamePRADEEP KUNTAL KUNTAL
License No.GNPC/ARC/0007/2017
Architect AddressC/O ALOK KUMAR TIWARI,NEAR SHANTINIWAS SCHOOL ,SHRI RAM NAGAR ,CHINIYA ROAD,GARHWA
Architect EmailIDm.tiwary8@gmail.com
Architect Mobile No7782927526
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No36
NorthPlot No. - 36
SouthPlot No. - 36
EastPlot No. - 36
WestRoad Width - 5.0
Owner's Details
NameSMT CHANDA DEVI
AddressSAHIJANA ,GARHWA ,JHARKHAND
Email IDalok.kumar462@gmail.com
Mobile No9905518279
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 70.00
2 Plot area as per Document by Applicant 70.00
3 Physical area measured at site 70.00
4 Area as per Site Visit (Site Visit Report) 70.00
5Area as per Drawing 70.00

Area of Plot Considered : 70.00

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 70.00
Deduction from Gross Plot area
- Surrender Free of Cost 0.35
0.35
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 69.65
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 59.57
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 0.35
- Common Plot 10.08
10.43
Balance Plot Area 59.57

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 48.76
Proposed Coverage Area ( 66.13 % ) 46.06
Total Prop. Coverage Area ( 66.13 % ) 46.06
Balance coverage area ( 3.88 % ) 2.70
FAR CHECK
Perm. FAR Area ( 1.80 ) 126.00
Total Perm. FAR area 126.00
Residential FAR 92.11
Proposed FAR Area 101.20
Total Proposed FAR Area 101.20
Consumed FAR (Factor) 1.45
Balance FAR Area 24.80
BUA CHECK
Total Proposed BuiltUp Area 138.17


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 5 5.00
Proposed Road Width as per Master Plan 5 -
Road Widening Width 5 0.05
Plot size (as per measurement) 70 70.00


Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 69.65 OK
Plot Width Sq.Mt. - - 7.00 OK
Plot Depth Sq.Mt. - - 9.95 OK
Access Width Sq.Mt. - - 5.00 OK
Plot Frontage Sq.Mt. - - 7.00 OK
Coverage Area Sq.Mt. - 48.76 46.06 OK
FAR Area Sq.Mt. - 126.00 101.20 OK
Consumed FAR Sq.Mt. - 1.80 1.45 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 3.48 10.08 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 10.08 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 1.38 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 2 4 OK
Car In Area Sq.Mt. - - 25.00 OK
Total Car In Area Sq.Mt. 25.00 - 25.00 OK
Visitor's Car Parking In Area Sq.Mt. 12.50 - 0.00 Failed
TwoWheeler In Area Sq.Mt. - - 6.00 OK
Other Parking In Area Sq.Mt. - - 5.96 OK
A-1 (BUILDING) Front Margin... ROAD WIDENING AREA(SURRENDERED FREE OF COST) Mt. 1.50 - 1.50 OK
Rear Margin Mt. 0.90 - 0.90 OK
Side1 Margin Mt. 0.90 - 0.90 OK
Side2 Margin Mt. - - 0.00 OK
A-1 (BUILDING) BldgLine for 5.0 MT WIDE MAINROAD Access Road Mt. 0.05 1.55 OK
A-1 (BUILDING) ResvRoad Width Check for... 5.0 MT WIDE MAINROAD Access Road Mt. 0.05 0.05 OK

Building Related Details
Name Description Unit Reqd Perm Proposed Status
PARKING FLOOR PLAN Required Floor Level Parking Driveway of 3.00 mt. distance is not Provided at PARKING FLOOR PLAN In A(BUILDING). Mt. - - - Failed
A(BUILDING) Height Mt. 9.05 8.25 OK
A(BUILDING) Second Floor - Height Mt. 2.75 - 2.75 OK
First Floor - Height Mt. 2.75 - 2.75 OK
Parking Floor - Height Mt. - - 2.75 OK
A(BUILDING) Terrace Floor - Height Mt. 1.00 1.20 1.00 OK
A(BUILDING) No. of Floors No. P + 2 3 OK
No. of Tenements No. - 2 OK
PARKING FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.000 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.138 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.000 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.138 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
SECOND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.000 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.137 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.000 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.400 OK
SUMP TANK Area Sq.Mt. - - 1.54 OK
Width Mt. - - 0.89 OK
Depth Mt. - - 1.73 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 1.95 OK
Width Mt. - - 1.13 OK
Depth Mt. - - 1.73 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.48 OK
Width Mt. - - 0.18 OK
Depth Mt. - - 2.73 OK
Height Mt. - - - OK
Ramp No. A(BUILDING) - PARKING FLOOR PLAN - No. No. 1 0 Failed
All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2) For GARHWA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2) For GARHWA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth upto 10.0 mt. and Plot width upto 10.0 mt., Margin required in Front shall be 1.5 mt., Rear 0.9 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Exceeding 50 mt. and upto 100 mt. shall be 5.1 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 50 mt. and upto 100 mt. shall be 5.1 mt. {As per Rule No. 34 Table No. 6}
Building Level
Floor Parking DriveWay Check The minimum width of the drive way meant exclusively for 2 wheelers should be 3.0 mt {As per Rule No. 41.2}
Building Height For old area, on Road width 4.8-6.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) Stilt floor is of minimum height of 2.4 meter. From floor to ceiling and not less than 2.10 mt. from the soffit of beams
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 4.8-6.1 mt. only Stilt + 2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
Building Level (Rooms)