No Image Found

Check List Report

Garhwa Nagar Panchayat

Version Number: 1.0.24
Version Date: 30/03/2018
Report Generated On: 06-04-2018

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictGARHWA
AuthorityGARHWA NAGAR PARISHAD
Inward_NoGNPC/BP/0021/W16/2018
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageSonpurwa
Taluka30
Architect Details
Architect NamePRADEEP KUNTAL KUNTAL
License No.GNPC/ARC/0007/2017
Architect AddressC/O ALOK KUMAR TIWARI,NEAR SHANTINIWAS SCHOOL ,SHRI RAM NAGAR ,CHINIYA ROAD,GARHWA
Architect EmailIDm.tiwary8@gmail.com
Architect Mobile No7782927526
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No1000
NorthRoad Width - 19.8
SouthPlot No. - 1000
EastPlot No. - 1000
WestPlot No. - 1000
Owner's Details
NameSMT SHANTI DEVI
AddressSONPURWA GARHWA
Email IDalok.kumar462@gmail.com
Mobile No9934808621
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 150.00
2 Plot area as per Document by Applicant 150.00
3 Physical area measured at site 150.00
4 Area as per Site Visit (Site Visit Report) 150.00
5Area as per Drawing 150.00

Area of Plot Considered : 150.00

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureMultistoried
Building TypeSingle Detached House
Gross Plot Area 150.00
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 150.00
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 134.42
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 15.58
15.58
Balance Plot Area 134.42

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 105.00
Proposed Coverage Area ( 62.87 % ) 94.30
Total Prop. Coverage Area ( 62.87 % ) 94.30
Balance coverage area ( 7.13 % ) 10.70
FAR CHECK
Perm. FAR Area ( 2.00 ) 300.00
Total Perm. FAR area 300.00
Residential FAR 94.30
Proposed FAR Area 94.30
Total Proposed FAR Area 94.30
Consumed FAR (Factor) 0.63
Balance FAR Area 205.70
BUA CHECK
Total Proposed BuiltUp Area 94.30


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 300 meter and upto 400 meter -
Existing Road Width 19.8 19.80
Proposed Road Width as per Master Plan 7.5 -
Road Widening Width 0 -
Plot size (as per measurement) 150 150.00


Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. 1000.00 - 150.00 Failed
Plot Width Sq.Mt. - - 10.00 OK
Plot Depth Sq.Mt. - - 15.00 OK
Access Width Sq.Mt. - - 19.80 OK
Plot Frontage Sq.Mt. - - 10.00 OK
Coverage Area Sq.Mt. - 105.00 94.30 OK
FAR Area Sq.Mt. - 300.00 94.30 OK
Consumed FAR Sq.Mt. - 2.00 0.63 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 15.00 15.58 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 15.58 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 1.94 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 2 5 OK
A-1 (BUILDING) Front Margin... 19.8MT WD MAINROAD Access Road Mt. - - 1000.10 OK
Rear Margin Mt. - - OK
Side1 Margin Mt. - - - OK
Side2 Margin Mt. - - - OK

Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (BUILDING) Height Mt. 31.70 - OK
A (BUILDING) Ground Floor - Height Mt. 2.75 - 3.90 OK
A (BUILDING) Terrace Floor - Height Mt. 1.00 1.20 1.00 OK
A (BUILDING) No. of Floors No. - 1 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.000 OK
STAIRCASE - Tread Width Mt. 0.225 0.230 OK
STAIRCASE - Riser Height Mt. 0.200 0.162 OK
STAIRCASE - Riser No. On Flight No. - 12 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.000 OK
STAIRCASE - Tread Width Mt. - 0.230 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. 2.100 - 2.400 OK
SUMP TANK Area Sq.Mt. - - 3.63 OK
Width Mt. - - 1.25 OK
Depth Mt. - - 2.91 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 3.78 OK
Width Mt. - - 1.25 OK
Depth Mt. - - 3.03 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.92 OK
Width Mt. - - 0.27 OK
Depth Mt. - - 3.39 OK
Height Mt. - - - OK
A (BUILDING) Toilet - No No. 1 - 0 Failed
Entrance Gate - No No. 1 - 1 OK
All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area The minimum size of plot for High rise building or Building with a height of 15 meters and above shall be 1000.0 sq.mt.{As per Rule no. 35.1 Note 4}
Plot Width The minimum size of plot for High rise building or Building with a height of 15 meters and above shall be 1000.0 sq.mt.{As per Rule no. 35.1 Note 4}
Plot Depth The minimum size of plot for High rise building or Building with a height of 15 meters and above shall be 1000.0 sq.mt.{As per Rule no. 35.1 Note 4}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage The minimum size of plot for High rise building or Building with a height of 15 meters and above shall be 1000.0 sq.mt.{As per Rule no. 35.1 Note 4}
FAR Area (1) In Affordable Housing, the Floor Area Ratio-FAR shall be 3.5 {As per Rule No. 83.13}
(2) For GARHWA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Affordable Housing, the Floor Area Ratio-FAR shall be 3.5 {As per Rule No. 83.13}
(2) For GARHWA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Building Level
Building Height For old area, on Road width above 18.30 mt., No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 18.30 mt. and above, No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
Accessory Use Number (1) Provision of toilets for visitors and separate toilets for guards and drivers shall be provided for Multistoried for Commercial and multidwelling units including Apartments Toilet
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)