No Image Found

Detail Scrutiny Report

Garhwa Nagar Panchayat

Version Number: 1.0.37
Version Date: 29/04/2019
Report Generated On: 06-07-2019
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictGARHWA
AuthorityGARHWA NAGAR PARISHAD
Inward_NoGNPC/BP/0029/W08/2019
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageSahijana
Taluka30
Architect Details
Architect NamePRADEEP KUNTAL KUNTAL
License No.GNPC/ARC/0007/2017
Architect AddressC/O ALOK KUMAR TIWARI,NEAR SHANTINIWAS SCHOOL ,SHRI RAM NAGAR ,CHINIYA ROAD,GARHWA
Architect EmailIDm.tiwary8@gmail.com
Architect Mobile No7782927526
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No437
NorthPlot No. - 437
SouthPlot No. - 437
EastPlot No. - 437
WestRoad Width - 6.5
Owner's Details
NameSHRI KIRAN TIRKEY
AddressSAHIJANA,GARHWA
Email IDm.tiwary8@gmail.com
Mobile No7992232995
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 273.34
2 Plot area as per Document by Applicant 273.34
3 Physical area measured at site 273.34
4 Area as per Site Visit (Site Visit Report) 273.34
5Area as per Drawing 273.34

Area of Plot Considered : 273.34

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 273.34
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 273.34
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 229.57
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 43.77
43.77
Balance Plot Area 229.57

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 164.00
Proposed Coverage Area ( 54.00 % ) 147.61
Total Prop. Coverage Area ( 54 % ) 147.61
Balance coverage area ( 6.00 % ) 16.39
FAR CHECK
Perm. FAR Area ( 2.00 ) 546.68
Total Perm. FAR area 546.68
Residential FAR 295.21
Proposed FAR Area 314.21
Total Proposed FAR Area 314.21
Consumed FAR (Factor) 1.15
Balance FAR Area 232.47
BUA CHECK
Total Proposed BuiltUp Area 427.83


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 6.5 6.50
Proposed Road Width as per Master Plan 6.5 -
Road Widening Width 0 -
Plot size (as per measurement) 273.34 273.34
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)

[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 13.67 43.77 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 43.77 0.00 0.00 - 3.61 - 90.00 No Access Provided OK



[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 8 OK


[-] Building Details (Table 4)

[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (BUILDING) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise


[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (BUILDING) 12.75 9.60 9.60 9.60 OK



[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (BUILDING) Second Floor 2.75 - 3.30 2.75 - 3.18 2.40 - 3.00 OK
First Floor 2.75 - 3.00 2.75 - 2.89 2.40 - 2.70 OK
Parking Floor - - 3.30 2.40 - 3.19 2.10 - 3.00 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (BUILDING) Terrace Floor 1.00 1.20 1.00 OK

[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (BUILDING) P + 4 3 - 2 OK

[-] Coverage Check (Table 4b)
Permissible Proposed Status
164.00 147.61 OK
60% 54%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
A-1 (BUILDING) - 147.61
Total Prop. Coverage Area - 147.61
Total Coverage Area 164.00 147.61

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Parking Resi. Stair
A (BUILDING) 1 427.83 113.61 295.22 19.00 314.22 314.22 02
Grand Total : 1 427.83 113.61 295.22 19.00 314.22 314.22 02


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (BUILDING)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Parking Floor 132.61 19.00 132.61 19.00
First Floor 147.61 147.61 147.61 147.61
Second Floor 147.61 147.61 147.61 147.61
Terrace Floor 0.00 0.00 0.00 0.00
Total : 427.83 314.22 427.83 314.22


[-] UnitBUA Table for Building :A (BUILDING)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
FIRST FLOOR PLAN FIRST FLOOR FLAT 147.61 130.38 11 1
SECOND FLOOR PLAN SPLIT SECOND FLOOR FLAT 147.61 130.38 11 1
Total: - - 295.22 260.76 22 2


[-] Building :A (BUILDING)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Parking Resi. Stair
Parking Floor 132.61 113.61 0.00 19.00 19.00 19.00 00
First Floor 147.61 0.00 147.61 0.00 147.61 147.61 01
Second Floor 147.61 0.00 147.61 0.00 147.61 147.61 01
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 427.83 113.61 295.22 19.00 314.22 314.22 02
Total Number of Same Buildings : 1
Total : 427.83 113.61 295.22 19.00 314.22 314.22 02
[-] Table 4c-2

FARArea
Building FAR Area:314.21
Existing FAR Area :0.00
Perm.
546.68
Prop.
314.21
Status
OK




[-] Margin Checks (Table 5)
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (BUILDING) 6.5 MT WIDE MAINROAD Access Road 3.00 3.00 1.80 2.02 0.90 1.00 0.90 1.00 OK






[-] Inner Building Details (Table 6)


No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.


[-] Parking Details (Table 7)

[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car Visitors Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (BUILDING) Residential Bungalow/ Dwelling / Non Apartment > 0 1 2.00 1 2 - - - - - - -
> 0 1 2.00 - - - 1 1 - - - -
Total : - - - - 2 3 - 1 1 - 0 5

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 3 37.50 OK
Total Car 2 25.00 3 37.50 OK
Visitor's Car Parking - - 1 12.50 OK
Total Visitor Parking 1 12.50 1 12.50 OK
TwoWheeler - - 5 10.00 OK
Total TwoWheeler - - 5 10.00 OK
Other Parking - - - 53.61 OK
Total 37.50 136.11 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

Driveway Parking Checks (Table 7d)
Plot Level Parking Driveway is as per the Rules
Floor Level Parking Driveway is as per the Rules


[-] Exemption Details (Table 8)



Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (BUILDING)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
FIRST FLOOR PLAN STAIRCASE 0.900 1.500 0.250 0.250 0.200 0.125 - 12 - - 0.000 OK
SECOND FLOOR PLAN STAIRCASE 0.900 1.500 0.250 0.250 0.200 0.137 - 12 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.500 - 0.250 - 0.000 - 0 - - 2.400 OK
PARKING FLOOR PLAN STAIRCASE 0.900 1.500 0.250 0.250 0.200 0.138 - 12 - - 0.000 OK


[-] Ramp Checks (Table 8b-a)
Ramp Name Width Depth Slope Status
Reqd Prop Reqd Prop Reqd Perm Prop
1.00 mt. long 1.50 mt. High 2.00 mt. Wide Natural Slope - 2.50 - 1.50 - - - OK


[-] Ramp Checks (Table 8b)
Building Name Floor Name No. Status
Reqd Prop
A (BUILDING) PARKING FLOOR PLAN 1 1 OK


[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SUMP TANK - - 2.96 - - 1.41 - - 2.10 - - 0.00 OK
RAIN WATER HARVESTING - - 4.00 - - 1.50 - - 2.68 - - 0.00 OK
ENT.GATE - - 1.28 - - 0.26 - - 4.88 - - 0.00 OK
SOLAR HEATING SYSTEM - - 5.41 - - 1.74 - - 3.12 - - 0.00 OK




[-] Floor Details (Table 9)


[-] Building:A (BUILDING)


[-] Floor:FIRST FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:SECOND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:PARKING FLOOR PLAN



No Room Found.





[-] Summary (Table 10)

Name Perm./Reqd. Proposed Status
Plot Area - 273.34 OK
Plot Width - 11.88 OK
Plot Depth - 23.01 OK
Access Width - 6.50 OK
Plot Frontage - 17.14 OK
Coverage Area 164.00 147.61 OK
FARArea
Bldg. FAR Area : 314.21
Sanctioned FAR Area :0.00
546.68 314.21 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For GARHWA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For GARHWA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 21-27 mt. and Plot width 10-15 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) Stilt floor is of minimum height of 2.4 meter. From floor to ceiling and not less than 2.10 mt. from the soffit of beams
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 6.1-7.5 mt. only Stilt + 4 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Building Level (Rooms)