No Image Found

Check List Report

Garhwa Nagar Panchayat

Version Number: 1.0.34
Version Date: 13/03/2019
Report Generated On: 13-03-2019

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictGARHWA
AuthorityGARHWA NAGAR PARISHAD
Inward_NoGNPC/BP/0014/W07/2019/ALT1
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentAddition or Alteration
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageSahijana
Taluka30
Layout Sanction Date29/6/2015
Architect Details
Architect NamePRADEEP KUNTAL KUNTAL
License No.GNPC/ARC/0007/2017
Architect AddressC/O ALOK KUMAR TIWARI,NEAR SHANTINIWAS SCHOOL ,SHRI RAM NAGAR ,CHINIYA ROAD,GARHWA
Architect EmailIDm.tiwary8@gmail.com
Architect Mobile No7782927526
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No4
NorthPlot No. - 4
SouthPlot No. - 4
EastRoad Width - 9.0
WestPlot No. - 4
Owner's Details
NameSMT SUNITA RANI
AddressSAHIJANA ,GARHWA
Email IDm.tiwary8@gmail.com
Mobile No6200602061
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 220.88
2 Plot area as per Document by Applicant 220.88
3 Physical area measured at site 220.88
4 Area as per Site Visit (Site Visit Report) 220.88
5Area as per Drawing 220.88

Area of Plot Considered : 220.88

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 220.88
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 220.88
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 174.01
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 46.87
46.87
Balance Plot Area 174.01

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 132.53
Proposed Coverage Area ( 51.95 % ) 114.75
Total Prop. Coverage Area ( 51.95 % ) 114.75
Balance coverage area ( 8.05 % ) 17.78
FAR CHECK
Perm. FAR Area ( 2.00 ) 441.76
Total Perm. FAR area 441.76
Residential FAR 344.25
Proposed FAR Area 362.25
Total Proposed FAR Area 362.25
Consumed FAR (Factor) 1.64
Balance FAR Area 79.51
BUA CHECK
Total Proposed BuiltUp Area 444.00


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 9 9.00
Proposed Road Width as per Master Plan 9 -
Road Widening Width 0 -
Plot size (as per measurement) 220.88 220.88
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 220.88 OK
Plot Width Mt. - - 14.27 OK
Plot Depth Mt. - - 15.48 OK
Access Width Mt. - - 9.00 OK
Plot Frontage Mt. - - 14.29 OK
Coverage Area Sq.Mt. - 132.53 114.75 OK
FAR Area Sq.Mt. - 441.76 362.25 OK
Consumed FAR Sq.Mt. - 2.00 1.64 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 11.04 46.87 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 46.87 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 3.74 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 2 5 OK
Car In Area Sq.Mt. - - 25.00 OK
Total Car In Area Sq.Mt. 50.00 - 25.00 Failed
Visitor's Car Parking In Area Sq.Mt. - - 12.50 OK
Total Visitor Parking In Area Sq.Mt. 25.00 - 12.50 Failed
TwoWheeler In Area Sq.Mt. - - 10.00 OK
Total TwoWheeler In Area Sq.Mt. - - 10.00 OK
Other Parking In Area Sq.Mt. - - 34.25 OK
A-1 (BUILDING) Front Margin... 9.0 MT WIDE MAINROAD Access Road Mt. 3.00 - 3.10 OK
Rear Margin Mt. 1.80 - 1.80 OK
Side1 Margin Mt. 0.90 - 1.50 OK
Side2 Margin Mt. 0.90 - 1.50 OK

Building Related Details
Name Description Unit Reqd Perm Proposed Status
PARKING FLOOR PLAN Required Floor Level Parking Driveway of 3.60 mt. distance is not Provided at PARKING FLOOR PLAN In A (BUILDING). Mt. - - - Failed
A (BUILDING) Height Mt. 16.60 11.00 OK
A (BUILDING) Third Floor - Height Mt. 2.75 - 2.75 OK
Third Floor - Clear Height Mt. 2.75 - 2.64 Failed
Third Floor - Beam Clear Height Mt. 2.40 - 2.52 OK
Second Floor - Height Mt. 2.75 - 2.75 OK
Second Floor - Clear Height Mt. 2.75 - 2.64 Failed
Second Floor - Beam Clear Height Mt. 2.40 - 2.52 OK
First Floor - Height Mt. 2.75 - 2.75 OK
First Floor - Clear Height Mt. 2.75 - 2.64 Failed
First Floor - Beam Clear Height Mt. 2.40 - 2.52 OK
Parking Floor - Height Mt. - - 2.75 OK
Parking Floor - Clear Height Mt. 2.40 - 2.64 OK
Parking Floor - Beam Clear Height Mt. 2.10 - 2.52 OK
A (BUILDING) Terrace Floor - Height Mt. 1.00 1.20 1.00 OK
A (BUILDING) No. of Floors No. P + 5 4 OK
No. of Tenements No. - 2 OK
PARKING FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.500 OK
STAIRCASE - Tread Width Mt. 0.250 0.300 OK
STAIRCASE - Riser Height Mt. 0.200 0.125 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
SECOND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.500 OK
STAIRCASE - Tread Width Mt. 0.250 0.300 OK
STAIRCASE - Riser Height Mt. 0.200 0.125 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
THIRD FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.500 OK
STAIRCASE - Tread Width Mt. 0.250 0.300 OK
STAIRCASE - Riser Height Mt. 0.200 0.125 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.500 OK
STAIRCASE - Tread Width Mt. - 0.300 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.400 OK
SUMP TANK Area Sq.Mt. - - 1.63 OK
Width Mt. - - 1.18 OK
Depth Mt. - - 1.38 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 3.86 OK
Width Mt. - - 1.55 OK
Depth Mt. - - 2.49 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 4.56 OK
Width Mt. - - 0.62 OK
Depth Mt. - - 7.33 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 4.96 OK
Width Mt. - - 1.71 OK
Depth Mt. - - 2.91 OK
Height Mt. - - - OK
Ramp No. A (BUILDING) - PARKING FLOOR PLAN - No. No. 1 1 OK


[-] Building:A (BUILDING)


[-] Floor:FIRST FLOOR PLAN



No Room Found.

[-] Floor:PARKING FLOOR PLAN



No Room Found.


[-] Floor:SECOND FLOOR PLAN

[-] Misc Checks (Table 9a)
Tnmt No. Room Name Area Width Depth Ventilation Status
Reqd Prop Reqd Prop Reqd Prop Reqd Prop
SPLIT SECOND FLOOR KITCHEN 2.37X1.85 5.00 4.37 1.80 1.85 1.80 2.37 0.44 2.16 Failed

[-] Floor:THIRD FLOOR PLAN

[-] Misc Checks (Table 9a)
Tnmt No. Room Name Area Width Depth Ventilation Status
Reqd Prop Reqd Prop Reqd Prop Reqd Prop
SPLIT SECOND FLOOR KITCHEN 2.37X1.85 5.00 4.37 1.80 1.85 1.80 2.37 0.44 2.16 Failed






[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For GARHWA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For GARHWA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building 10-13.3 mt. Ht. having Plot Depth 15-21 mt. and Plot width 10-15 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Floor Parking DriveWay Check The minimum width of the drive way meant exclusively for 2 wheelers should be 3.0 mt {As per Rule No. 41.2}
Building Height For old area, on Road width 7.50-9.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 19.25 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) Stilt floor is of minimum height of 2.4 meter. From floor to ceiling and not less than 2.10 mt. from the soffit of beams
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 7.5-9.1 mt. only Stilt + 5 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Building Level (Rooms)