[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictGARHWA
AuthorityGARHWA NAGAR PARISHAD
Inward_NoGNPC/BP/0029/W13/2020
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageSahijana
Taluka30
Architect Details
Architect NameKUMARI MEENAKSHI TIWARI
License No.GNPC/ENG/0006/2019
Architect AddressCHINIYA ROAD ,SHRI RAM NAGAR ,PIPRAKALA,GARHWA
Architect EmailIDm.tiwary8@gmail.com
Architect Mobile No7782927526
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No544
NorthPlot No. - SURVEY ROAD
SouthPlot No. - SANDHYA DEVI
EastPlot No. - APARNA MISHRA
WestRoad Width - 3.05
Owner's Details
NameSHRI VIKASH KUMAR TIWARY
AddressSAHIJANA ,GARHWA
Email IDm.tiwary8@gmail.com
Mobile No9523753738
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 97.34
2 Plot area as per Document by Applicant 97.34
3 Physical area measured at site 97.34
4 Area as per Site Visit (Site Visit Report) 97.34
5Area as per Drawing 97.34

Area of Plot Considered : 97.34

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 97.34
Deduction from Gross Plot area
- Surrender Free of Cost 4.60
4.60
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 92.74
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 76.42
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 4.60
- Common Plot 16.32
20.92
Balance Plot Area 76.42

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 64.92
Proposed Coverage Area ( 58.89 % ) 54.61
Total Prop. Coverage Area ( 58.89 % ) 54.61
Balance coverage area ( 11.12 % ) 10.31
FAR CHECK
Perm. FAR Area ( 1.20 ) 116.81
Total Perm. FAR area 116.81
Residential FAR 54.61
Proposed FAR Area 54.61
Total Proposed FAR Area 54.61
Consumed FAR (Factor) 0.56
Balance FAR Area 62.20
BUA CHECK
Total Proposed BuiltUp Area 54.61


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 3.05 3.05
Proposed Road Width as per Master Plan 3.05 -
Road Widening Width 0 0.50
Plot size (as per measurement) 97.34 97.34
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 92.74 OK
Plot Width Mt. - - 9.20 OK
Plot Depth Mt. - - 10.08 OK
Access Width Mt. - - 3.05 OK
Plot Frontage Mt. - - 9.20 OK
Coverage Area Sq.Mt. - 64.92 54.61 OK
FAR Area Sq.Mt. - 116.81 54.61 OK
Consumed FAR Sq.Mt. - 1.20 0.56 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 4.64 16.32 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 16.32 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 2.03 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 2 5 OK
A-1 (BUILDING) Front Margin... ROAD WIDENING AREA(SURRENDERED FREE OF COST) Mt. - - 1000.10 OK
Rear Margin Mt. - - OK
Side1 Margin Mt. - - - OK
Side2 Margin Mt. - - - OK
A-1 (BUILDING) BldgLine for 3.05 MT WIDE MAINROAD Access Road Mt. 0.27 2.00 OK
A-1 (BUILDING) ResvRoad Width Check for... 3.05 MT WIDE MAINROAD Access Road Mt. 0.27 0.50 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (BUILDING) Ground Floor - Height Mt. 2.75 - 3.90 OK
Ground Floor - Clear Height Mt. 2.75 - 3.78 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 3.60 OK
A (BUILDING) Terrace Floor - Height Mt. 1.00 1.20 1.00 OK
A (BUILDING) No. of Floors No. G + 1 1 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.000 OK
STAIRCASE - Tread Width Mt. 0.225 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.177 OK
STAIRCASE - Riser No. On Flight No. - 21 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.000 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. 2.100 - 2.400 OK
SUMP TANK Area Sq.Mt. - - 0.56 OK
Width Mt. - - 0.73 OK
Depth Mt. - - 0.77 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 0.83 OK
Width Mt. - - 0.77 OK
Depth Mt. - - 1.07 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 1.15 OK
Width Mt. - - 0.33 OK
Depth Mt. - - 3.46 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 0.85 OK
Width Mt. - - 0.76 OK
Depth Mt. - - 1.11 OK
Height Mt. - - - OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth less than 3.60 mt., the Floor Area Ratio-FAR shall be 1.2 {As per Rule No.39, Table 15, Note i}
(2) For GARHWA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth less than 3.60 mt., the Floor Area Ratio-FAR shall be 1.2 {As per Rule No.39, Table 15, Note i}
(2) For GARHWA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Building Line Check The min. width of Road for length of Road upto 50 mt. shall be 3.6 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road upto 50 mt. shall be 3.6 mt. {As per Rule No. 34 Table No. 6}
Building Level
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width upto 3.6 mt. only G+1 floors shall be allowed {As per Rule No. 39.1 Note 1}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Building Level (Rooms)