No Image Found   

Detail Scrutiny Report

Garhwa Nagar Panchayat

Version Number: 1.0.51  
Version Date: 16/10/2020 
Report Generated On: 09-12-2020 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictGARHWA
AuthorityGARHWA NAGAR PARISHAD
Inward_NoGNPC/BP/0031/W11/2020
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageGarhwa Bajar
Taluka30
Architect Details
Architect NameKUMARI MEENAKSHI TIWARI
License No.GNPC/ENG/0006/2019
Architect AddressCHINIYA ROAD ,SHRI RAM NAGAR ,PIPRAKALA,GARHWA
Architect EmailIDm.tiwary8@gmail.com
Architect Mobile No7782927526
Plot Details
Plot Use Mixed
Plot SubUse Resi+Comm
PlotNearbyReligiousStructure NA
Plot/SubPlot No1338
NorthPlot No. - 1338
SouthPlot No. - 1338
EastPlot No. - 1338
WestRoad Width - 9
Owner's Details
NameSHRI AJAY KUMAR
AddressROCKY MOHALLA,GARHWA
Email IDm.tiwary8@gmail.com
Mobile No8340690851
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 102.70
2 Plot area as per Document by Applicant 102.70
3 Physical area measured at site 102.70
4 Area as per Site Visit (Site Visit Report) 102.70
5Area as per Drawing 102.70

Area of Plot Considered : 102.70

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyMixed
Plot SubUse -
Higher Plot Use
Higher Plot Sub UseResi+Comm
Lower Plot Use
Lower Plot Sub Use
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 102.70
Deduction from Gross Plot area
- Surrender Free of Cost 0.68
0.68
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 102.01
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 93.76
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 0.68
- Common Plot 8.26
8.94
Balance Plot Area 93.76

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 71.41
Proposed Coverage Area ( 34.05 % ) 34.74
Total Prop. Coverage Area ( 34.05 % ) 34.74
Balance coverage area ( 35.95 % ) 36.67
FAR CHECK
Perm. FAR Area ( 2.00 ) 205.40
Total Perm. FAR area 205.40
Residential FAR 34.74
Commercial FAR 34.74
Proposed FAR Area 69.48
Total Proposed FAR Area 69.48
Consumed FAR (Factor) 0.68
Balance FAR Area 135.92
BUA CHECK
Total Proposed BuiltUp Area 69.48


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 9 9.00
Proposed Road Width as per Master Plan 9 -
Road Widening Width 0 0.07
Plot size (as per measurement) 102.7 102.70
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 10.20 8.26 Failed


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 8.26 0.00 0.00 - 0.91 - 80.38 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 4 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (BUILDING) Commercial Commercial Bldg Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (BUILDING) 15.65 6.00 6.00 6.10 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (BUILDING) First Floor 2.75 - 3.00 2.75 - 2.88 2.40 - 2.70 OK
Ground Floor 2.75 - 3.00 2.75 - 2.88 2.40 - 2.70 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (BUILDING) Terrace Floor 1.00 1.20 1.00 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (BUILDING) G + 5 2 - 2 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
71.41 34.74 OK
70% 34.05%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (BUILDING) - 34.74
  Total Prop. Coverage Area - 34.74
  Total Coverage Area 71.41 34.74

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
A (BUILDING) 1 69.48 34.74 69.48 69.48 02
Grand Total : 1 69.48 34.74 69.48 69.48 02


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (BUILDING)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 34.74 34.74 34.74 34.74
First Floor 34.74 34.74 34.74 34.74
Terrace Floor 0.00 0.00 0.00 0.00
Total : 69.48 69.48 69.48 69.48


[-] UnitBUA Table for Building :A (BUILDING)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN GROUND FLOOR SHOP 34.74 31.48 1 1
FIRST FLOOR PLAN FIRST FLOOR FLAT 34.74 31.48 1 1
Total: - - 69.48 62.96 2 2


[-] Building :A (BUILDING)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
Ground Floor 34.74 0.00 34.74 34.74 01
First Floor 34.74 34.74 34.74 34.74 01
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 69.48 34.74 69.48 69.48 02
Total Number of Same Buildings : 1
Total : 69.48 34.74 69.48 69.48 02
[-] Table 4c-2

  FAR Area
Building FAR Area:69.48
Existing FAR Area :0.00
Perm.
205.40
Prop.
69.48
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (BUILDING) ROAD WIDENING AREA(SURRENDERED FREE OF COST) 4.50 2.15 2.00 1.50 1.50 2.90 - 0.00 Failed
4.50 2.15






[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car Visitors Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (BUILDING) Mixed Resi+Comm > 0 200 21.72 1 1 - - - - - - -
> 0 200 21.72 - - - - - - 1 1 -
> 0 200 21.72 1 1 - - - - - - -
> 0 200 21.72 - - - - - - 1 1 -
Total : - - - - 2 2 - 0 1 - 2 3

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 2 25.00 OK
Total Car 2 25.00 2 25.00 OK
Visitor's Car Parking - - 1 12.50 OK
Total Visitor Parking - - 1 12.50 OK
TwoWheeler - - 3 6.00 OK
Total TwoWheeler 2 4.00 3 6.00 OK
Total 29.00 49.50 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

Driveway Parking Checks (Table 7d)
Required Plot Level VP Parking Driveway of 3.60 mt. distance is not Provided at A-1 (BUILDING).
Floor Level Parking Driveway is as per the Rules
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (BUILDING)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.750 1.249 0.225 0.250 0.200 0.125 - 12 - - 0.000 OK
FIRST FLOOR PLAN STAIRCASE 0.750 1.249 0.225 0.250 0.200 0.125 - 12 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.249 - 0.250 - 0.000 - 0 2.100 - 2.400 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SUMP TANK - - 0.19 - - 0.39 - - 0.50 - - 0.00 OK
RAIN WATER HARVESTING - - 0.25 - - 0.43 - - 0.58 - - 0.00 OK
ENT.GATE - - 0.22 - - 0.08 - - 3.80 - - 0.00 OK
SOLAR HEATING SYSTEM - - 0.16 - - 0.30 - - 0.55 - - 0.00 OK


   
   


[-] Floor Details (Table 9)
   

[-] Building:A (BUILDING)


[-] Floor:GROUND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:FIRST FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 102.01 OK
  Plot Width - 8.42 OK
  Plot Depth - 12.12 OK
  Access Width - 9.00 OK
  Plot Frontage - 9.79 OK
  Coverage Area 71.41 34.74 OK
  FAR Area
Bldg. FAR Area : 69.48
Sanctioned FAR Area :0.00
205.40 69.48 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For GARHWA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For GARHWA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Parking DriveWay Check The minimum width of the drive way meant exclusively for 2 wheelers should be 3.0 mt {As per Rule No. 41.2}
Margin Rule For Non-highrise Commercial Building upto 16.4 mt. Ht. having Plot Depth 10-15 mt. and Plot width upto 10 mt., Margin required in Front shall be 4.5 mt., Rear 2.0 mt. and Atleast 1.5 mt. shall be provided at one side. {As per Rule No. 36 Table 10 & 11 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017 }
Building Level
Building Height For old area, on Road width 7.50-9.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 19.25 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 7.5-9.1 mt. only G+5 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Building Level (Rooms)