-
No Image Found   

Check List Report

Garhwa Nagar Panchayat

Version Number: 1.0.55  
Version Date: 16/10/2020 
Report Generated On: 29-06-2021 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictGARHWA
AuthorityGARHWA NAGAR PARISHAD
Inward_NoGNPC/BP/0020/W09/2021
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageDipuwan
Taluka30
Architect Details
Architect NameKUMARI MEENAKSHI TIWARI
License No.GNPC/ENG/0006/2019
Architect AddressCHINIYA ROAD ,SHRI RAM NAGAR ,PIPRAKALA,GARHWA
Architect EmailIDm.tiwary8@gmail.com
Architect Mobile No7782927526
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No81
NorthPlot No. - 81
SouthPlot No. - 81
EastPlot No. - 81
WestRoad Width - 5
Owner's Details
NameSHRI MANISH KUMAR DUBEY
AddressDIPUWAN ,GARHWA
Email IDm.tiwary8@gmail.com
Mobile No8292825651
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 157.97
2 Plot area as per Document by Applicant 157.97
3 Physical area measured at site 157.97
4 Area as per Site Visit (Site Visit Report) 157.97
5Area as per Drawing 157.97

Area of Plot Considered : 157.97

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 157.97
Deduction from Gross Plot area
- Surrender Free of Cost 3.21
3.21
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 154.76
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 133.84
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 3.21
- Common Plot 20.91
24.13
Balance Plot Area 133.84

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 108.33
Proposed Coverage Area ( 60.32 % ) 93.35
Total Prop. Coverage Area ( 60.32 % ) 93.35
Balance coverage area ( 9.68 % ) 14.98
FAR CHECK
Perm. FAR Area ( 1.80 ) 284.35
Total Perm. FAR area 284.35
Residential FAR 93.35
Proposed FAR Area 102.85
Total Proposed FAR Area 102.85
Consumed FAR (Factor) 0.65
Balance FAR Area 181.50
BUA CHECK
Total Proposed BuiltUp Area 171.70


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 5 5.00
Proposed Road Width as per Master Plan 5 -
Road Widening Width 0 0.25
Plot size (as per measurement) 157.97 157.97
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 154.76 OK
Plot Width Mt. - - 11.66 OK
Plot Depth Mt. - - 13.27 OK
Access Width Mt. - - 5.00 OK
Plot Frontage Mt. - - 12.88 OK
Coverage Area Sq.Mt. - 108.33 93.35 OK
FAR Area Sq.Mt. - 284.35 102.85 OK
Consumed FAR Sq.Mt. - 1.80 0.65 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 7.74 20.91 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 20.91 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 1.32 OK
Tree Cover (Plantation) - Angle Degree - 76.89 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 2 7 OK
A-1 (BUILDING) Front Margin... ROAD WIDENING AREA(SURRENDERED FREE OF COST) Mt. 2.00 - 2.00 OK
Rear Margin Mt. 1.50 - 1.50 OK
Side1 Margin Mt. 0.90 - 1.00 OK
Side2 Margin Mt. 0.90 - 1.00 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (BUILDING) Height Mt. 9.75 6.00 OK
A (BUILDING) First Floor - Height Mt. 2.75 - 3.00 OK
First Floor - Clear Height Mt. 2.75 - 2.88 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.70 OK
Parking Floor - Height Mt. - - 3.00 OK
Parking Floor - Clear Height Mt. 2.40 - 2.88 OK
Parking Floor - Beam Clear Height Mt. 2.10 - 2.70 OK
A (BUILDING) Terrace Floor - Height Mt. - - 1.00 OK
A (BUILDING) No. of Floors No. P + 2 2 OK
No. of Tenements No. - 1 OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.000 OK
STAIRCASE - Tread Width Mt. 0.225 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.125 OK
STAIRCASE - Riser No. On Flight No. - 12 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
PARKING FLOOR STAIRCASE - Flight Width Mt. 0.750 1.000 OK
STAIRCASE - Tread Width Mt. 0.225 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.125 OK
STAIRCASE - Riser No. On Flight No. - 12 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.000 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. 2.100 - 2.400 OK
SUMP TANK Area Sq.Mt. - - 1.00 OK
Width Mt. - - 0.78 OK
Depth Mt. - - 1.29 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 1.00 OK
Width Mt. - - 0.78 OK
Depth Mt. - - 1.28 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.83 OK
Width Mt. - - 0.26 OK
Depth Mt. - - 3.27 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 1.29 OK
Width Mt. - - 0.78 OK
Depth Mt. - - 1.66 OK
Height Mt. - - - OK
A (BUILDING) Rain Water Harvesting - No No. 1 - 1 OK
PLOT 1.00 mt. long 1.50 mt. High 2.00 mt. Wide Natural Slope - Width Mt. - 2.50 OK
1.00 mt. long 1.50 mt. High 2.00 mt. Wide Natural Slope - Depth Mt. - 1.50 OK
1.00 mt. long 1.50 mt. High 2.00 mt. Wide Natural Slope - Slope Ratio - - - OK
Ramp No. A (BUILDING) - PARKING FLOOR - No. No. 1 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2) For GARHWA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2) For GARHWA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 10-15 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.0 mt., Rear 1.5 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 4.8-6.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) Stilt floor is of minimum height of 2.4 meter. From floor to ceiling and not less than 2.10 mt. from the soffit of beams
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 4.8-6.1 mt. only Stilt + 2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)