No Image Found   

Detail Scrutiny Report

Garhwa Nagar Panchayat

Version Number: 1.0.66  
Version Date: 16/10/2020 
Report Generated On: 11-09-2023 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictGARHWA
AuthorityGARHWA NAGAR PARISHAD
Inward_NoGNPC/BP/0058/W11/2023
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageSahijana
Taluka30
Architect Details
Architect NameRESHAN ALI
License No.GNPC/ENG/0005/2017
Architect AddressAT:- WARSI COMPLEX, KUTTCHERY ROAD, NEAR H.K PETROL PUMP
Architect EmailIDarchitectakhtar@gmail.com
Architect Mobile No9835159686
Plot Details
Plot Use Commercial
Plot SubUse Commercial Bldg
PlotNearbyReligiousStructure NA
Plot/SubPlot No16,17
NorthPlot No. - 28
SouthRoad Width - 7.0
EastPlot No. - Anil Kumar
WestPlot No. - Sunil Kumar
Owner's Details
Name1) Anil Kumar Gupta 2) Sunil Kumar Gupta 3) Ajay Kumar Gupta
AddressChinya Road,Sahijana,Po+Ps-Garhwa,Dist-Garhwa,Jharkhand
Email IDresha.ali.30@gmail.com
Mobile No7070011115
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 625.50
2 Plot area as per Document by Applicant 625.50
3 Physical area measured at site 625.50
4 Area as per Site Visit (Site Visit Report) 625.50
5Area as per Drawing 625.50

Area of Plot Considered : 625.50

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyCommercial
Plot SubUse Commercial Bldg
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 625.50
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 625.50
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 574.03
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 51.47
51.47
Balance Plot Area 574.03

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 312.75
Proposed Coverage Area ( 45.64 % ) 285.45
Total Prop. Coverage Area ( 45.64 % ) 285.45
Balance coverage area ( 4.36 % ) 27.30
FAR CHECK
Perm. FAR Area ( 2.000 ) 1251.00
Total Perm. FAR area 1251.00
Commercial FAR 856.35
Proposed FAR Area 868.38
Total Proposed FAR Area 868.38
Consumed FAR (Factor) 1.39
Balance FAR Area 382.62
BUA CHECK
Total Proposed BuiltUp Area 1141.81


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 7 7.00
Proposed Road Width as per Master Plan 7 -
Road Widening Width 0 -
Plot size (as per measurement) 625.5 625.50
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 31.27 51.47 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 51.47 0.00 0.00 - 3.41 - 90.00 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 14 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (BUILDING) Commercial Commercial Bldg Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (BUILDING) 16.40 11.82 12.00 11.82 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (BUILDING) Third Floor 2.75 - 3.00 2.75 - 2.88 2.40 - 2.75 OK
Second Floor 2.75 - 3.00 2.75 - 2.88 2.40 - 2.75 OK
First Floor 2.75 - 3.00 2.75 - 2.88 2.40 - 2.75 OK
Ground Floor 2.75 - 3.00 2.75 - 2.88 2.40 - 2.75 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (BUILDING) Terrace Floor - - 1.00 - - 1.00 - - 1.00 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (BUILDING) G + 4 4 - 3 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
312.75 285.45 OK
50% 45.64%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (BUILDING) - 285.45
  Total Prop. Coverage Area - 285.45
  Total Coverage Area 312.75 285.45

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Parking Commercial Stair
A (BUILDING) 1 1141.81 273.43 856.35 12.03 868.38 868.38 03
Grand Total : 1 1141.81 273.43 856.35 12.03 868.38 868.38 03


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (BUILDING)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 285.46 12.03 285.46 12.03
First Floor 285.45 285.45 285.45 285.45
Second Floor 285.45 285.45 285.45 285.45
Third Floor 285.45 285.45 285.45 285.45
Terrace Floor 0.00 0.00 0.00 0.00
Total : 1141.81 868.38 1141.81 868.38


[-] UnitBUA Table for Building :A (BUILDING)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
FIRST FLOOR SHOP TENAMENT SHOP 285.45 265.70 6 1
SECOND FLOOR SHOP TENAMENT SHOP 285.45 265.70 6 1
THIRD FLOOR SHOP TENAMENT SHOP 285.45 265.70 6 1
Total: - - 856.35 797.10 18 3


[-] Building :A (BUILDING)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Parking Commercial Stair
Ground Floor 285.46 273.43 0.00 12.03 12.03 12.03 00
First Floor 285.45 0.00 285.45 0.00 285.45 285.45 01
Second Floor 285.45 0.00 285.45 0.00 285.45 285.45 01
Third Floor 285.45 0.00 285.45 0.00 285.45 285.45 01
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 1141.81 273.43 856.35 12.03 868.38 868.38 03
Total Number of Same Buildings : 1
Total : 1141.81 273.43 856.35 12.03 868.38 868.38 03
[-] Table 4c-2

  FAR Area
Building FAR Area:868.38
Existing FAR Area :0.00
Perm.
1251.00
Prop.
868.38
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (BUILDING) 7.0 M MAIN ROAD Access Road 6.50 6.50 4.00 4.00 3.00 3.00 3.00 3.00 OK






[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car Visitors Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (BUILDING) Commercial Commercial Bldg > 0 200 822.71 1 3 - - - - - - -
> 0 200 822.71 - - - - - - 1 9 -
Total : - - - - 3 7 - 0 3 - 9 7

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 7 87.50 OK
Total Car 3 37.50 7 87.50 OK
Visitor's Car Parking - - 3 37.50 OK
Total Visitor Parking - - 3 37.50 OK
TwoWheeler - - 7 14.00 OK
Total TwoWheeler 9 18.00 7 14.00 FAILED
Other Parking - - - 134.43 OK
Total 55.50 287.43 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

[-] Driveway Parking Checks (Table 7d)
Building/Plot Name Floor Name Driveway Name Width Status
Reqd Perm Prop
A (BUILDING) GROUND FLOOR Drriveway 3.60 - 16.50 OK

   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (BUILDING)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR STAIRCASE 0.900 1.000 0.250 0.250 0.200 0.115 - 9 - - 0.000 OK
FIRST FLOOR STAIRCASE 0.900 1.000 0.250 0.250 0.200 0.115 - 9 - - 0.000 OK
SECOND FLOOR STAIRCASE 0.900 1.000 0.250 0.250 0.200 0.115 - 9 - - 0.000 OK
THIRD FLOOR STAIRCASE 0.900 1.000 0.250 0.250 0.200 0.115 - 9 - - 0.000 OK
TERRACE FLOOR STAIRCASE - 1.000 - 0.250 - 0.000 - 0 - - 2.275 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SUMP TANK - - 8.90 - - 2.31 - - 3.85 - - 0.00 OK
RAIN WATER HARVESTING - - 12.02 - - 3.34 - - 3.60 - - 0.00 OK
ENT.GATE - - 8.14 - - 0.60 - - 13.67 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (BUILDING) Rain Water Harvesting 1 - 1 OK
Entrance Gate 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (BUILDING)


[-] Floor:GROUND FLOOR



No Room Found.


[-] Floor:FIRST FLOOR



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:SECOND FLOOR



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:THIRD FLOOR



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 625.50 OK
  Plot Width - 22.50 OK
  Plot Depth - 27.80 OK
  Access Width - 7.00 OK
  Plot Frontage - 22.50 OK
  Coverage Area 312.75 285.45 OK
  FAR Area
Bldg. FAR Area : 868.38
Sanctioned FAR Area :0.00
1251.00 868.38 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For GARHWA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For GARHWA NAGAR PARISHAD, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Non-highrise Commercial Building upto 16.4 mt. Ht. having Plot Depth 27-33 mt. and Plot width 21-27 mt., Margin required in Front shall be 6.5 mt., Rear 4.0 mt. and 3.0 mt. shall be provided on both side. {As per Rule No. 36 Table 10 & 11}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate