No Image Found   

Check List Report

Hussainabad Nagar Panchayat

Version Number: 1.0.61  
Version Date: 16/10/2020 
Report Generated On: 25-11-2021 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictPALAMU
AuthorityHussainabad Nagar Panchayat
Inward_NoHNPC/BP/0016/W09/2021
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageSyed toli
Taluka27
Architect Details
Architect NameMERAJ SARWER ANSARI
License No.HNPC/ENG/0003/2021
Architect AddressVILL POST BISHRAMPUR PS RANKA DIST GARHWA
Architect EmailIDmerajsarweransari333@gmail.com
Architect Mobile No9341161017
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No1332
NorthPlot No. - makan tuta bataur sahan sayyda azra khatun urf gudiya
SouthRoad Width - 3.5
EastPlot No. - 1332 ansh plot of niz seller
WestPlot No. - wall sayyed kajim hussain zaidi
Owner's Details
NameAbdul Majid Qadri
AddressNear Imambada road , Sayyed Toli Ward - 9
Email IDmerajsarweransari333@gmail.com
Mobile No6203603209
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 243.30
2 Plot area as per Document by Applicant 243.30
3 Physical area measured at site 243.30
4 Area as per Site Visit (Site Visit Report) 243.30
5Area as per Drawing 243.39

Area of Plot Considered : 243.30

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Residential Bldg/Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 243.30
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 243.30
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 218.16
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 25.14
25.14
Balance Plot Area 218.16

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 145.98
Proposed Coverage Area ( 59.47 % ) 144.70
Total Prop. Coverage Area ( 59.47 % ) 144.70
Balance coverage area ( 0.53 % ) 1.28
FAR CHECK
Perm. FAR Area ( 2.00 ) 486.60
Total Perm. FAR area 486.60
Residential FAR 144.70
Proposed FAR Area 144.70
Total Proposed FAR Area 144.70
Consumed FAR (Factor) 0.59
Balance FAR Area 341.90
BUA CHECK
Total Proposed BuiltUp Area 144.70


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 6.2 6.20
Proposed Road Width as per Master Plan 6.2 -
Road Widening Width 6.2 -
Plot size (as per measurement) 243.3 243.39
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 243.30 OK
Plot Width Mt. - - 8.85 OK
Plot Depth Mt. - - 27.49 OK
Access Width Mt. - - 6.20 OK
Plot Frontage Mt. - - 8.12 OK
Coverage Area Sq.Mt. - 145.98 144.70 OK
FAR Area Sq.Mt. - 486.60 144.70 OK
Consumed FAR Sq.Mt. - 2.00 0.59 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 24.33 25.14 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 25.14 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 4.31 OK
Tree Cover (Plantation) - Angle Degree - 89.67 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 2 6 OK
AAA-1 (BUILDING) Front Margin... 6.2 M WIDE ROAD Mt. 4.00 - 5.45 OK
Rear Margin Mt. 2.50 - 3.07 OK
Side1 Margin Mt. 0.90 - 0.90 OK
Side2 Margin Mt. - - 0.00 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
AAA (BUILDING) Height Mt. 14.75 3.25 OK
AAA (BUILDING) Ground Floor - Height Mt. 2.75 - 3.25 OK
Ground Floor - Clear Height Mt. 2.75 - 3.15 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.93 OK
Plinth - Height Mt. 0.45 - 0.45 OK
Plinth - Clear Height Mt. - - 0.45 OK
Plinth - Beam Clear Height Mt. - - 0.45 OK
AAA (BUILDING) Terrace Floor - Height Mt. - - 1.00 OK
AAA (BUILDING) No. of Floors No. G + 4 1 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 0.990 OK
STAIRCASE - Tread Width Mt. 0.225 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.148 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 0.990 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. 2.100 - 3.150 OK
Toilet Area Sq.Mt. - 5.00 4.58 OK
Width Mt. - - 1.58 OK
Depth Mt. - - 2.91 OK
Height Mt. - - - OK
SUMP TANK Area Sq.Mt. - - 3.64 OK
Width Mt. - - 1.87 OK
Depth Mt. - - 1.95 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 2.10 OK
Width Mt. - - 1.38 OK
Depth Mt. - - 1.52 OK
Height Mt. - - - OK
AAA (BUILDING) Rain Water Harvesting - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Hussainabad Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Hussainabad Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 27-33 mt. and Plot width upto 10 mt., Margin required in Front shall be 4.0 mt., Rear 2.5 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building SUMP TANK
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)