Check List Report

Latehar Nagar Panchayat

Version Number: 1.0.62  
Version Date: 16/10/2020 
Report Generated On: 05-03-2022 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictLATEHAR
AuthorityLATEHAR NAGAR PANCHAYAT
Inward_NoLNPC/BP/0017/W03/2019/ALT2
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentAddition or Alteration
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageLatehar
Taluka33
Layout Sanction Date20/12/2019
Architect Details
Architect Namelaw chaturvedi
License No.LNPC/ENG/0004/2018
Architect AddressVILL-LEMBOGRA,POST GANGI ,P.S. BARACHATTI GAYA
Architect EmailIDlaw8688@gmail.com
Architect Mobile No8987252771
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No806
NorthPlot No. - sangana devi
SouthRoad Width - 3.66
EastRoad Width - 2.44
WestPlot No. - niz venders
Owner's Details
NamePriyadarshani Pandit
AddressDuruwa Latehar
Email IDpanditg688@gmail.com
Mobile No8987252771
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 220.41
2 Plot area as per Document by Applicant 220.41
3 Physical area measured at site 220.41
4 Area as per Site Visit (Site Visit Report) 220.41
5Area as per Drawing 210.15

Area of Plot Considered : 210.15

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 210.15
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 210.15
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 195.85
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 14.30
14.30
Balance Plot Area 195.85

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 147.10
Proposed Coverage Area ( 59.14 % ) 124.28
Total Prop. Coverage Area ( 59.14 % ) 124.28
Balance coverage area ( 10.86 % ) 22.82
FAR CHECK
Perm. FAR Area ( 1.50 ) 315.22
Total Perm. FAR area 315.22
Residential FAR 248.56
Proposed FAR Area 248.56
Total Proposed FAR Area 248.56
Consumed FAR (Factor) 1.18
Balance FAR Area 66.66
BUA CHECK
Total Proposed BuiltUp Area 248.56


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 3.66 3.66
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 220.41 210.15
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 210.15 OK
Plot Width Mt. - - 17.23 OK
Plot Depth Mt. - - 12.19 OK
Access Width Mt. - - 3.66 OK
Plot Frontage Mt. - - 17.23 OK
Coverage Area Sq.Mt. - 147.10 124.28 OK
FAR Area Sq.Mt. - 315.22 248.56 OK
Consumed FAR Sq.Mt. - 1.50 1.18 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 10.51 14.30 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 14.30 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 1.03 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 2 6 OK
A-1 (SRI PRIYEDARSHANI PANDIT) Front Margin... 3.66 M WIDE ROAD Mt. 2.00 - 2.13 OK
Rear Margin Mt. 1.50 - 1.56 OK
Side1 Margin Mt. 1.00 - 1.07 OK
Side2 Margin Mt. 1.00 - 1.07 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (SRI PRIYEDARSHANI PANDIT) Height Mt. 7.62 6.11 OK
A (SRI PRIYEDARSHANI PANDIT) First Floor - Height Mt. 2.75 - 3.05 OK
First Floor - Clear Height Mt. 2.75 - 2.95 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.82 OK
Existing Ground Floor - Height Mt. 2.75 - 3.05 OK
Existing Ground Floor - Clear Height Mt. 2.75 - 2.95 OK
Existing Ground Floor - Beam Clear Height Mt. 2.40 - 2.82 OK
Plinth - Height Mt. 0.45 - 0.91 OK
Plinth - Clear Height Mt. - - 0.91 OK
Plinth - Beam Clear Height Mt. - - 0.91 OK
A (SRI PRIYEDARSHANI PANDIT) Terrace Floor - Height Mt. - - 1.15 OK
A (SRI PRIYEDARSHANI PANDIT) No. of Floors No. G + 2 2 OK
No. of Tenements No. - 1 OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.067 OK
STAIRCASE - Tread Width Mt. - 0.254 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. 2.100 - 2.389 OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.067 OK
STAIRCASE - Tread Width Mt. 0.225 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.160 OK
STAIRCASE - Riser No. On Flight No. - 9 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
Sewage Treatment Plant Area Sq.Mt. - - 1.26 OK
Width Mt. - - 0.94 OK
Depth Mt. - - 1.35 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 1.28 OK
Width Mt. - - 0.75 OK
Depth Mt. - - 1.71 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 1.46 OK
Width Mt. - - 0.90 OK
Depth Mt. - - 1.61 OK
Height Mt. - - - OK
A (SRI PRIYEDARSHANI PANDIT) Rain Water Harvesting - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For Latehar Nagar Panchayat, Max. 1.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For Latehar Nagar Panchayat, Max. 1.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 10-15 mt. and Plot width 15-21 mt., Margin required in Front shall be 2.0 mt., Rear 1.5 mt. and 1.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) -
(6) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)