General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictLATEHAR
AuthorityLATEHAR NAGAR PANCHAYAT
Inward_NoLNPC/BP/0003/W09/2019
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageLatehar
Taluka33
Architect Details
Architect Namelaw chaturvedi
License No.LNPC/ENG/0004/2018
Architect AddressVILL-LEMBOGRA,POST GANGI ,P.S. BARACHATTI GAYA
Architect EmailIDlaw8688@gmail.com
Architect Mobile No8987252771
Plot Details
Plot Use Business
Plot SubUse Business Office
PlotNearbyReligiousStructure NA
Plot/SubPlot No27
NorthRoad Width - ROAD
SouthPlot No. - OTHER PLOT
EastPlot No. - OTHER PLOT
WestPlot No. - OTHER PLOT
Owner's Details
NameBRIJ BHUSAN PRASAD SINGH
AddressTAPAKHAS LATHAR
Email IDlaw8688@gmail.com
Mobile No8987252771
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 441.25
2 Plot area as per Document by Applicant 441.25
3 Physical area measured at site 441.25
4 Area as per Site Visit (Site Visit Report) 441.25
5Area as per Drawing 439.98

Area of Plot Considered : 439.98

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyBusiness
Plot SubUse Business Office
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 439.98
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 439.98
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 389.65
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 50.33
50.33
Balance Plot Area 389.65

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 219.99
Proposed Coverage Area ( 28.45 % ) 125.16
Total Prop. Coverage Area ( 28.45 % ) 125.16
Balance coverage area ( 21.55 % ) 94.83
FAR CHECK
Perm. FAR Area ( 2.00 ) 879.96
Total Perm. FAR area 879.96
Commercial FAR 375.49
Proposed FAR Area 375.49
Total Proposed FAR Area 375.49
Consumed FAR (Factor) 0.85
Balance FAR Area 504.47
BUA CHECK
Total Proposed BuiltUp Area 375.48


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 12.2 12.20
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 441.25 439.98
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK




[-] Rules
Topic Rule
Plot Level
Plot Area The minimum size of plot for Office category shall be 300.0 sq.mt. {As per Rule No. 35.1, Table 7}
Plot Width The minimum size of plot for Office category shall be 300.0 sq.mt. {As per Rule No. 35.1, Table 7}
Plot Depth The minimum size of plot for Office category shall be 300.0 sq.mt. {As per Rule No. 35.1, Table 7}
Access Width The minimum width of abutting road for Office category shall be 12.20 mt. {As per Rule No. 35.1, Table 7}
Plot Frontage The minimum size of plot for Office category shall be 300.0 sq.mt. {As per Rule No. 35.1, Table 7}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Latehar Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Latehar Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Commercial Building upto 16.4 mt. Ht. having Plot Depth 33-39 mt. and Plot width 10-15 mt., Margin required in Front shall be 7.0 mt., Rear 4.5 mt. and 2.0 mt. shall be provided on both side. {As per Rule No. 36 Table 10 & 11}
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
StairCase (1) No Rule Defined
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting