General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictLATEHAR
AuthorityLATEHAR NAGAR PANCHAYAT
Inward_NoLNPC/BP/0016/W01/2024
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageBanpur
Taluka33
Architect Details
Architect Namelaw chaturvedi
License No.LNPC/ENG/0004/2018
Architect AddressVILL-LEMBOGRA,POST GANGI ,P.S. BARACHATTI GAYA
Architect EmailIDlaw8688@gmail.com
Architect Mobile No8987252771
Plot Details
Plot Use Commercial
Plot SubUse Shop
PlotNearbyReligiousStructure NA
Plot/SubPlot No480
NorthPlot No. - NIZ VENDER
SouthPlot No. - RAMESH KUMAR
EastPlot No. - NIZ VENDER
WestRoad Width - 9.14
Owner's Details
NameCHANCHAL DEVI
AddressBANPUR
Email IDCHAN8614@GMAIL.COM
Mobile No9304565139
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 344.00
2 Plot area as per Document by Applicant 344.00
3 Physical area measured at site 344.00
4 Area as per Site Visit (Site Visit Report) 344.00
5Area as per Drawing 275.74

Area of Plot Considered : 275.74

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyCommercial
Plot SubUse Shop
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 275.74
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 275.74
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 247.91
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 27.83
27.83
Balance Plot Area 247.91

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 137.87
Proposed Coverage Area ( 49.51 % ) 136.53
Total Prop. Coverage Area ( 49.51 % ) 136.53
Balance coverage area ( 0.49 % ) 1.34
FAR CHECK
Perm. FAR Area ( 2.000 ) 551.48
Total Perm. FAR area 551.48
Commercial FAR 409.59
Proposed FAR Area 409.59
Total Proposed FAR Area 409.59
Consumed FAR (Factor) 1.49
Balance FAR Area 141.89
BUA CHECK
Total Proposed BuiltUp Area 409.59


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 9.14 9.14
Proposed Road Width as per Master Plan 9.14 -
Road Widening Width 9.14 -
Plot size (as per measurement) 344 275.74
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 275.74 OK
Plot Width Mt. - - 8.08 OK
Plot Depth Mt. - - 34.14 OK
Access Width Mt. - - 9.14 OK
Plot Frontage Mt. - - 8.08 OK
Coverage Area Sq.Mt. - 137.87 136.53 OK
FAR Area Sq.Mt. - 551.48 409.59 OK
Consumed FAR Sq.Mt. - 2.00 1.49 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 13.79 27.83 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 27.83 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 4.57 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 12 OK
Car In Area Sq.Mt. - - 75.00 OK
Total Car In Area Sq.Mt. 75.00 - 75.00 OK
TwoWheeler In Area Sq.Mt. - - 32.00 OK
Total TwoWheeler In Area Sq.Mt. 32.00 - 32.00 OK
DriveWay PLOT - - - DRIVEWAY - Width No. 3.60 - 5.01 OK
A (CHAMCHAL) - GROUND FLOOR PLAN - DRIVEWAY - Width No. 3.00 - 5.57 OK
A (CHAMCHAL) - GROUND FLOOR PLAN - DRIVEWAY - Width No. 3.60 - 5.57 OK
A-1 (CHAMCHAL) Front Margin... 9.14m MAINROAD Access Road Mt. 7.00 - 7.01 OK
Rear Margin Mt. 4.50 - 4.57 OK
Side1 Margin Mt. 1.00 - 1.02 OK
Side2 Margin Mt. 1.00 - 1.00 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (CHAMCHAL) Height Mt. 20.72 9.14 OK
A (CHAMCHAL) Second Floor - Height Mt. 2.75 - 3.05 OK
Second Floor - Clear Height Mt. 2.75 - 2.95 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
First Floor - Height Mt. 2.75 - 3.05 OK
First Floor - Clear Height Mt. 2.75 - 2.95 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.60 OK
Ground Floor - Height Mt. 2.75 - 3.05 OK
Ground Floor - Clear Height Mt. 2.75 - 2.95 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.60 OK
Plinth - Height Mt. 0.45 - 0.91 OK
Plinth - Clear Height Mt. - - 0.91 OK
Plinth - Beam Clear Height Mt. - - 0.91 OK
A (CHAMCHAL) Terrace Floor - Height Mt. - - 0.99 OK
Terrace Floor - Clear Height Mt. - - 0.99 OK
Terrace Floor - Beam Clear Height Mt. - - 0.99 OK
A (CHAMCHAL) No. of Floors No. G + 6 3 OK
No. of Tenements No. - 3 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.016 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.191 OK
STAIRCASE - Riser No. On Flight No. - 9 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TYPICAL - 1& 2 FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.016 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.191 OK
STAIRCASE - Riser No. On Flight No. - 9 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.016 OK
STAIRCASE - Tread Width Mt. - 0.254 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 3.127 OK
SUMP TANK Area Sq.Mt. - - 2.30 OK
Width Mt. - - 1.36 OK
Depth Mt. - - 1.70 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 1.86 OK
Width Mt. - - 1.54 OK
Depth Mt. - - 1.54 OK
Height Mt. - - - OK
A (CHAMCHAL) Rain Water Harvesting - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Latehar Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Latehar Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule (1) For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) The minimum width of the drive way meant exclusively for 2 wheelers should be 3.0 mt {As per Rule No. 41.2}
Margin Rule For narrow plots,the setbacks on sides may be compensated in front and rear setbacks so as to ensure that the overall aggregate setbacks are maintained in the site, subject to maintaining a minimum of side setback of 1m in case of buildings of height up to 10.0 mt.
Building Level
Building Height For old area, on Road width 9.10-12.20 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 23.10 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 9.1-12.20 mt. only G+6 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)