General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictJAMTARA
AuthorityMIHIJHAM NAGAR PANCHAYAT
Inward_NoMJNPC/BP/0004/W08/2022
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageMihijam
Taluka34
Architect Details
Architect Nameirshad hussain khan
License No.MJNPC/ENG/0002/2016
Architect AddressNEW COLONY POKHARTALLA, MIHIJAM, Mihijam/???????, Jamtara/???????, Jamtara/????????, Jharkhand/??????
Architect EmailIDirshadkhan15c30@gmail.com
Architect Mobile No7050723016
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No1072/G/1/A
North -
South -
East -
West -
Owner's Details
NameNISHA SAO
AddressMIHIJAM
Email IDnishasao@gmail.com
Mobile No9163342733
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 518.81
2 Plot area as per Document by Applicant 518.81
3 Area as per Site Visit (Site Visit Report) 328.77
4Area as per Drawing 518.81

Area of Plot Considered : 328.77

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
Unit
Development Detail :
Plotplot
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 328.77
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 328.77
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 298.67
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 30.10
30.10
Balance Plot Area 298.67

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 197.26
Proposed Coverage Area ( 52.15 % ) 171.45
Total Prop. Coverage Area ( 52.15 % ) 171.45
Balance coverage area ( 7.85 % ) 25.81
FAR CHECK
Perm. FAR Area ( 2.00 ) 657.54
Total Perm. FAR area 657.54
Residential FAR 328.76
Proposed FAR Area 328.76
Total Proposed FAR Area 328.76
Consumed FAR (Factor) 1.00
Balance FAR Area 328.78
BUA CHECK
Total Proposed BuiltUp Area 342.90


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 250 meter and upto 300 meter -
Existing Road Width 7.5 7.50
Proposed Road Width as per Master Plan 7.5 -
Road Widening Width 0.6 -
Plot size (as per measurement) 328.77 518.81
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 328.77 OK
Plot Width Mt. - - 18.45 OK
Plot Depth Mt. - - 28.12 OK
Access Width Mt. - - 7.50 OK
Plot Frontage Mt. - - 18.60 OK
Coverage Area Sq.Mt. - 197.26 171.45 OK
FAR Area Sq.Mt. - 657.54 328.76 OK
Consumed FAR Sq.Mt. - 2.00 1.00 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 16.44 30.10 OK
Common Plot Normal Open Space - Minimum Area Sq.Mt. - 30.10 OK
Normal Open Space - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 12 OK
A-1 (NISHA SAO) Front Margin... 7.5 m.MAINROAD Mt. 4.00 - 4.28 OK
Rear Margin Mt. 2.50 - 9.19 OK
Side1 Margin Mt. 1.00 - 2.15 OK
Side2 Margin Mt. 1.00 - 1.81 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (NISHA SAO) Height Mt. 15.53 6.00 OK
A (NISHA SAO) First Floor - Height Mt. 2.75 - 3.00 OK
First Floor - Clear Height Mt. 2.75 - 2.90 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.65 OK
Ground Floor - Height Mt. 2.75 - 3.00 OK
Ground Floor - Clear Height Mt. 2.75 - 2.90 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.65 OK
A (NISHA SAO) Terrace Floor - Height Mt. - - 1.00 OK
A (NISHA SAO) No. of Floors No. G + 5 2 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.050 OK
STAIRCASE - Tread Width Mt. 0.225 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.136 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.050 OK
STAIRCASE - Tread Width Mt. 0.225 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.136 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.050 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. 2.100 - 2.400 OK
RAIN WATER HARVESTING Area Sq.Mt. - - 7.37 OK
Width Mt. - - 2.44 OK
Depth Mt. - - 3.33 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 1.87 OK
Width Mt. - - 0.48 OK
Depth Mt. - - 3.87 OK
Height Mt. - - - OK
A.C.PLANT ROOM Area Sq.Mt. - - 4.49 OK
Width Mt. - - 0.90 OK
Depth Mt. - - 5.01 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 2.77 OK
Width Mt. - - 0.86 OK
Depth Mt. - - 3.24 OK
Height Mt. - - - OK
Area Sq.Mt. - - 2.77 OK
Width Mt. - - 0.86 OK
Depth Mt. - - 3.24 OK
Height Mt. - - - OK
A (NISHA SAO) Rain Water Harvesting - No No. 1 - 1 OK
Solar Water Heating System - No No. 1 - 2 OK
   
   

[-] Building:A (NISHA SAO)


[-] Floor:GROUND FLOOR PLAN

[-] Misc Checks (Table 9a)
Tnmt No. Room Name Area Width Depth Ventilation Status
Reqd Prop Reqd Prop Reqd Prop Reqd Prop

[-] Floor:FIRST FLOOR PLAN

[-] Misc Checks (Table 9a)
Tnmt No. Room Name Area Width Depth Ventilation Status
Reqd Prop Reqd Prop Reqd Prop Reqd Prop






[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Mihijham Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Mihijham Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot ; ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 27-33 mt. and Plot width 15-21 mt., Margin required in Front shall be 4.0 mt., Rear 2.5 mt. and 1.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 7.50-9.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 19.25 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 7.5-9.1 mt. only G+5 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) No need to check distance from Building ENT.GATE
(4) Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(5) No need to check distance from Building A.C.PLANT ROOM
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) For Individual residential buildings having more than 150 sq m. plinth area, Provisions of Solar Water Heating System shall be done Solar Water Heating System
Building Level (Rooms)