No Image Found

Failed List Report

Rajmahal Nagar Panchayat

Version Number: 1.0.11
Version Date: 04/05/2017
Report Generated On: 03-06-2017

General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictSAHIBGANJ
AuthorityRAJMAHAL NAGAR PANCHAYAT
Inward_NoRNPC/BP/0001/W03/2017
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageKasimganj
Taluka29
Architect Details
Architect NameRAJ GOTHWAL
License No.RNPC/ARC/0001/2016
Architect Address10 DECIMAL DESIGN STUDIO ,103 First Floor, Rajan House, H Block Market, Ashok Vihar Phase-1
Architect EmailID10DECIMAL@GMAIL.COM
Architect Mobile No9953738378
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No143
North-1 -
South-1 -
East-1 -
West-1 -
Owner's Details
NameKiran Devi Jain
AddressPlot no 244, Gram Kasim Ganj Post Office and Thana Rajmahal
Email IDaliknayanghosh@gmail.com
Mobile No9955042351
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 133.93
2 Plot area as per Document by Applicant 133.93
3 Physical area measured at site 133.93
4 Area as per Site Visit (Site Visit Report) 133.93
5Area as per Drawing 133.86

Area of Plot Considered : 133.86

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Residential Bldg/Apartment
Building StructureMultistoried
Building TypeSingle Detached House
Gross Plot Area 133.86
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 133.86
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 109.52
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 24.34
24.34
Balance Plot Area 109.52

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 93.70
Proposed Coverage Area ( 61.46 % ) 82.27
Total Prop. Coverage Area ( 61.46 % ) 82.27
Balance coverage area ( 8.54 % ) 11.43
FAR CHECK
Perm. FAR Area ( 1.50 ) 200.79
Total Perm. FAR area 200.79
Residential FAR 164.54
Proposed FAR Area 164.54
Total Proposed FAR Area 164.54
Consumed FAR (Factor) 1.23
Balance FAR Area 36.25
BUA CHECK
Total Proposed BuiltUp Area 164.54


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road -
Existing Road Width 0 3.60
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 133.93 -





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For Rajmahal Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For Rajmahal Nagar Panchayat, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth upto 10.0 mt. and Plot width 15-21 mt., Margin required in Front shall be 1.5 mt., Rear 0.9 mt. and 1.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 3.6-4.8 mt. only Stilt + 2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
Building Level (Rooms)