Failed List Report

Ramgarh Nagar Parishad

Version Number: 1.0.54  
Version Date: 16/10/2020 
Report Generated On: 12-03-2021 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictRAMGARH
AuthorityRAMGARH NAGAR PARISHAD
Inward_NoRNP/BP/0012/W26/2020
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageVillage1
Taluka35
Architect Details
Architect NameIsmail Ajad
License No.RNP/DFTMN/0003/2019
Architect AddressS/o.- Md Muslim Ansari, Upar Tola, Post- Hesla, Manuwa, Ramgarh
Architect EmailIDsmileazad@gmail.com
Architect Mobile No7739616348
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No1248
NorthPlot No. - JANAK MAHTO
SouthRoad Width - 4.57
EastPlot No. - PULAK KUMAR
WestPlot No. - INDUL MAHTO
Owner's Details
NameSMT.SUSHMA PRASAD
AddressKAITHA
Email IDSMILEAZAD@GMAIL.COM
Mobile No9852308483
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 128.73
2 Plot area as per Document by Applicant 126.44
3 Physical area measured at site 126.44
4 Area as per Site Visit (Site Visit Report) 126.44
5Area as per Drawing 126.44

Area of Plot Considered : 126.44

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
Plotplot
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeNA
Gross Plot Area 126.44
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 126.44
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 112.64
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 13.80
13.80
Balance Plot Area 112.64

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 88.51
Proposed Coverage Area ( 55.13 % ) 69.70
Total Prop. Coverage Area ( 55.13 % ) 69.70
Balance coverage area ( 14.88 % ) 18.81
FAR CHECK
Perm. FAR Area ( 1.50 ) 189.66
Total Perm. FAR area 189.66
Residential FAR 139.39
Proposed FAR Area 139.39
Total Proposed FAR Area 139.39
Consumed FAR (Factor) 1.10
Balance FAR Area 50.27
BUA CHECK
Total Proposed BuiltUp Area 139.40


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 4.57 4.57
Proposed Road Width as per Master Plan 3.6 -
Road Widening Width 0 -
Plot size (as per measurement) 126.44 126.44
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK
   



[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For Ramgarh Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For Ramgarh Nagar Parishad, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 10-15 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.0 mt., Rear 1.5 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building SUMP TANK
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
(7) -
(8) No need to check distance from Building SOLAR HEATING SYSTEM
Building Level (Rooms)