No Image Found

Check List Report

Simdega Nagar Panchayat

Version Number: 1.0.20
Version Date: 27/01/2018
Report Generated On: 07-02-2018

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictSIMDEGA
AuthoritySIMDEGA NAGAR PANCHAYAT
Inward_NoSINPC/BP/0012/W06/2018
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageKhijri
Taluka36
Architect Details
Architect NameMD RAGIB SAYEED
License No.SINPC/ENG/0001/2017
Architect AddressC/o Md. Ragib Sayeed, Opposite Gulzar Gali, Main Road Simdega.
Architect EmailIDragibsanu@gmail.com
Architect Mobile No7070131170
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No208
North -
South -
East -
West -
Owner's Details
NameSUCHITA SORENG
AddressMARIYAMPUR,SIMDEGA
Email IDragibsayeed393@gmail.com
Mobile No7050524140
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 384.59
2 Plot area as per Document by Applicant 356.02
3 Physical area measured at site 356.02
4 Area as per Site Visit (Site Visit Report) 356.02
5Area as per Drawing 356.02

Area of Plot Considered : 356.02

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Residential Bldg/Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 356.02
Deduction from Gross Plot area
- Surrender Free of Cost 23.94
23.94
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 332.08
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 262.10
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 23.94
- Common Plot 69.98
93.92
Balance Plot Area 262.10

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 199.25
Proposed Coverage Area ( 28.34 % ) 94.11
Total Prop. Coverage Area ( 28.34 % ) 94.11
Balance coverage area ( 31.66 % ) 105.14
FAR CHECK
Perm. FAR Area ( 1.50 ) 534.03
Total Perm. FAR area 534.03
Residential FAR 188.23
Proposed FAR Area 188.23
Total Proposed FAR Area 188.23
Consumed FAR (Factor) 0.53
Balance FAR Area 345.80
BUA CHECK
Total Proposed BuiltUp Area 188.22


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 100 meter and upto 250 meter -
Existing Road Width 3 3.60
Proposed Road Width as per Master Plan 3.6 -
Road Widening Width 1.53 10.74
Plot size (as per measurement) 356.02 356.02


[-] Road width Details Checks
No Rule Status
1 For Existing Road Width, value as per site visit and value as per drawing should be same. Failed

Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 332.08 OK
Plot Width Sq.Mt. - - 15.03 OK
Plot Depth Sq.Mt. - - 22.09 OK
Access Width Sq.Mt. - - 3.60 OK
Plot Frontage Sq.Mt. - - 2.23 OK
Coverage Area Sq.Mt. - 199.25 94.11 OK
FAR Area Sq.Mt. - 534.03 188.23 OK
Consumed FAR Sq.Mt. - 1.50 0.53 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 33.21 69.98 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 69.98 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 7.54 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 24 OK
A-1 (SMT SUCHITA SORENG) Front Margin... ROAD WIDENING AREA(SURRENDERED FREE OF COST) Mt. 3.00 - 3.55 OK
Rear Margin Mt. 1.80 - 8.06 OK
Side1 Margin Mt. 1.00 - 2.24 OK
Side2 Margin Mt. 1.00 - 2.00 OK
A-1 (SMT SUCHITA SORENG) BldgLine for 3.60 MTR WIDE ROAD Access Road Mt. 1.25 7.82 OK
A-1 (SMT SUCHITA SORENG) ResvRoad Width Check for... 3.60 MTR WIDE ROAD Access Road Mt. 1.25 1.50 OK

Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (SMT SUCHITA SORENG) Height Mt. 10.00 6.20 OK
A (SMT SUCHITA SORENG) First Floor - Height Mt. 2.75 - 3.10 OK
Ground Floor - Height Mt. 2.75 - 3.10 OK
Plinth - Height Mt. - - 0.60 OK
A (SMT SUCHITA SORENG) Terrace Floor - Height Mt. 1.00 1.20 1.03 OK
A (SMT SUCHITA SORENG) No. of Floors No. P + 2 2 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.050 OK
STAIRCASE - Tread Width Mt. 0.225 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.129 OK
STAIRCASE - Riser No. On Flight No. - 12 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.050 OK
STAIRCASE - Tread Width Mt. 0.225 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.129 OK
STAIRCASE - Riser No. On Flight No. - 12 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.050 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. 2.100 - 2.500 OK
Sewage Treatment Plant Area Sq.Mt. - 0.99 0.98 OK
Width Mt. - - 0.93 OK
Depth Mt. - - 1.06 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 2.00 OK
Width Mt. - - 1.06 OK
Depth Mt. - - 1.89 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 1.38 OK
Width Mt. - - 1.06 OK
Depth Mt. - - 1.31 OK
Height Mt. - - - OK
A (SMT SUCHITA SORENG) Rain Water Harvesting - No No. 1 - 1 OK
All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 21-27 mt. and Plot width 15-21 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and 1.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Exceeding 100 mt. and upto 300 mt. shall be 6.1 mt. {As per Rule No. 34 Table No. 6 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 100 mt. and upto 300 mt. shall be 6.1 mt. {As per Rule No. 34 Table No. 6 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 3.6-4.8 mt. only Stilt + 2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) -
(6) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
Building Level (Rooms)