No Image Found

Check List Report

Simdega Nagar Panchayat

Version Number: 1.0.30
Version Date: 30/06/2018
Report Generated On: 27-11-2018

[-] Collapse All


General Details
Region JHARKHAND URBAN LOCAL BODIES
District SIMDEGA
Authority SIMDEGA NAGAR PANCHAYAT
Inward_No SINPC/BP/0068/W03/2018
Application Type General Proposal
Project Type Building Permission
Nature of Development New
Location of Development Area New Area
City Area/TPScheme No NA
Village Saldega
Taluka 36
Architect Details
Architect Name RAJESH KUMAR
License No. SINPC/DFTMN/0006/2017
Architect Address SALDEGA MUNDA TOLI
Architect EmailID rajconsultancy.401@rediffmail.com
Architect Mobile No 9386222833
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No 553,560
North -
South -
East -
West -
Owner's Details
Name SUNIL LUGUN
Address SALDEGA , SIMDEGA
Email ID rajconsultancy.401@rediffmail.com
Mobile No 9973094815
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 848.48
2 Plot area as per Document by Applicant 848.48
3 Area as per Site Visit (Site Visit Report) 848.48
4 Area as per Drawing 848.48

Area of Plot Considered : 848.48

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
Unit Meters
Development Detail :
Plot PLOT
Plot Occupancy Residential
Plot SubUse Residential Bldg/Apartment
Building Structure Non-Highrise
Building Type Single Detached House
Gross Plot Area 848.48
Deduction from Gross Plot area
- Surrender Free of Cost 53.21
53.21
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 795.27
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 607.68
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 53.21
- Common Plot 187.59
240.80
Balance Plot Area 607.68

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 477.16
Proposed Coverage Area ( 18.69 % ) 148.64
Total Prop. Coverage Area ( 18.69 % ) 148.64
Balance coverage area ( 41.31 % ) 328.52
FAR CHECK
Perm. FAR Area ( 1.50 ) 1272.72
Total Perm. FAR area 1272.72
Residential FAR 272.33
Proposed FAR Area 272.33
Total Proposed FAR Area 272.33
Consumed FAR (Factor) 0.32
Balance FAR Area 1000.39
BUA CHECK
Total Proposed BuiltUp Area 297.30


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 3.6 3.60
Proposed Road Width as per Master Plan 4 -
Road Widening Width 0 1.30
Plot size (as per measurement) 848.48 848.48


Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 795.27 OK
Plot Width Sq.Mt. - - 36.79 OK
Plot Depth Sq.Mt. - - 21.62 OK
Access Width Sq.Mt. - - 3.60 OK
Plot Frontage Sq.Mt. - - 40.97 OK
Coverage Area Sq.Mt. - 477.16 148.64 OK
FAR Area Sq.Mt. - 1272.72 272.33 OK
Consumed FAR Sq.Mt. - 1.50 0.32 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 79.53 187.59 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 187.59 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 6.01 OK
Tree Cover (Plantation) - Angle Degree - 88.84 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 12 OK
Car In Area Sq.Mt. - - 37.50 OK
Total Car In Area Sq.Mt. 37.50 - 37.50 OK
Visitor's Car Parking In Area Sq.Mt. 12.50 - 25.00 OK
TwoWheeler In Area Sq.Mt. 6.00 - 12.00 OK
Other Parking In Area Sq.Mt. - - 301.00 OK
A-1 (BUILDING) Front Margin... ROAD WIDENING AREA(SURRENDERED FREE OF COST) Mt. 3.00 - 6.27 OK
Rear Margin Mt. 1.80 - 4.29 OK
Side1 Margin Mt. 2.00 - 6.74 OK
Side2 Margin Mt. 2.00 - 13.68 OK

Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (BUILDING) Height Mt. 10.00 6.10 OK
A (BUILDING) First Floor - Height Mt. 2.75 - 3.05 OK
Ground Floor - Height Mt. 2.75 - 3.05 OK
Plinth - Height Mt. 0.45 - 0.61 OK
A (BUILDING) Terrace Floor - Height Mt. 1.00 1.20 1.00 OK
A (BUILDING) No. of Floors No. G + 2 2 OK
No. of Tenements No. - 3 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.003 OK
STAIRCASE - Tread Width Mt. 0.225 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.139 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.003 OK
STAIRCASE - Tread Width Mt. 0.225 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.139 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.003 OK
STAIRCASE - Tread Width Mt. - 0.254 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. 2.100 - 3.048 OK
RAIN WATER HARVESTING Area Sq.Mt. - - 32.25 OK
Width Mt. - - 5.01 OK
Depth Mt. - - 6.44 OK
Height Mt. - - - OK
A (BUILDING) Rain Water Harvesting - No No. 1 - 1 OK
All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In New Area, FAR for plot which lies on road less than 6.10 m. the width shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In New Area, FAR for plot which lies on road less than 6.10 m. the width shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 21-27 mt. and Plot width 33-39 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and 2.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height In New Area, for plot which lies on road less than 6.10 m. Perm. Building Ht. shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number In New Area, for plot which lies on road less than 6.10 m. Perm. No of Floor shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
Accessory Use Number Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
Building Level (Rooms)