No Image Found

Failed List Report

Simdega Nagar Panchayat

Version Number: 1.0.30
Version Date: 30/06/2018
Report Generated On: 12-11-2018

[-] Collapse All


General Details
Region JHARKHAND URBAN LOCAL BODIES
District SIMDEGA
Authority SIMDEGA NAGAR PANCHAYAT
Inward_No SINPC/BP/0066/W01/2018
Application Type General Proposal
Project Type Building Permission
Nature of Development New
Location of Development Area New Area
City Area/TPScheme No NA
Village Gotra
Taluka 36
Architect Details
Architect Name RAJESH KUMAR
License No. SINPC/DFTMN/0006/2017
Architect Address SALDEGA MUNDA TOLI
Architect EmailID rajconsultancy.401@rediffmail.com
Architect Mobile No 9386222833
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No 2830
North -
South -
East -
West -
Owner's Details
Name SEEMA DEVI
Address SUNDARPUR , SIMDEGA
Email ID rajconsultancy.401@rediffmail.com
Mobile No 7250427413
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 364.02
2 Plot area as per Document by Applicant 364.02
3 Area as per Site Visit (Site Visit Report) 364.02
4 Area as per Drawing 364.02

Area of Plot Considered : 364.02

[-] Table 2b
Proposal Detail :
Unit Meters
Development Detail :
Plot PLOT
Plot Occupancy Residential
Plot SubUse Residential Bldg/Apartment
Building Structure Non-Highrise
Building Type Single Detached House
Gross Plot Area 364.02
Deduction from Gross Plot area
- Surrender Free of Cost 44.05
44.05
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 319.97
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 225.30
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 44.05
- Common Plot 94.67
138.71
Balance Plot Area 225.30

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 191.98
Proposed Coverage Area ( 38.76 % ) 124.01
Total Prop. Coverage Area ( 38.76 % ) 124.01
Balance coverage area ( 21.24 % ) 67.97
FAR CHECK
Perm. FAR Area ( 1.20 ) 436.82
Total Perm. FAR area 436.82
Residential FAR 242.57
Proposed FAR Area 242.57
Total Proposed FAR Area 242.57
Consumed FAR (Factor) 0.67
Balance FAR Area 194.25
BUA CHECK
Total Proposed BuiltUp Area 248.02


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 3.5 3.50
Proposed Road Width as per Master Plan 4 -
Road Widening Width 0.5 5.90
Plot size (as per measurement) 364.02 364.02





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In New Area, FAR for plot which lies on road less than 6.10 m. the width shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In New Area, FAR for plot which lies on road less than 6.10 m. the width shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For narrow plots,the setbacks on sides may be compensated in front and rear setbacks so as to ensure that the overall aggregate setbacks are maintained in the site, subject to maintaining a minimum of side setback of 1m in case of buildings of height up to 10.0 mt.
Building Line Check The min. width of Road for length of Road exceeding 1000 mt. shall be 15.30 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road exceeding 1000 mt. shall be 15.30 mt. {As per Rule No. 34 Table No. 6}
Building Level
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number In New Area, for plot which lies on road less than 6.10 m. Perm. No of Floor shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
Accessory Use Number Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
Building Level (Rooms)