No Image Found

Detail Scrutiny Report

Simdega Nagar Panchayat

Version Number: 1.0.30
Version Date: 30/06/2018
Report Generated On: 19-12-2018

[-] Collapse All


General Details
Region JHARKHAND URBAN LOCAL BODIES
District SIMDEGA
Authority SIMDEGA NAGAR PANCHAYAT
Inward_No SINPC/BP/0086/W02/2018
Application Type General Proposal
Project Type Building Permission
Nature of Development New
Location of Development Area New Area
City Area/TPScheme No NA
Village Gotra
Taluka 36
Architect Details
Architect Name MD RAGIB SAYEED
License No. SINPC/ENG/0001/2017
Architect Address C/o Md. Ragib Sayeed, Opposite Gulzar Gali, Main Road Simdega.
Architect EmailID ragibsanu@gmail.com
Architect Mobile No 7070131170
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No 2541
North -
South -
East -
West -
Owner's Details
Name THEODORE BAXLA
Address BHOGTATOLI, SIMDEGA.
Email ID ragibsayeed393@gmail.com
Mobile No 9334549234
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 809.66
2 Plot area as per Document by Applicant 785.70
3 Physical area measured at site 785.70
4 Area as per Site Visit (Site Visit Report) 785.70
5 Area as per Drawing 785.70

Area of Plot Considered : 785.70

[-] Table 2b
Proposal Detail :
Unit Meters
Development Detail :
Plot PLOT
Plot Occupancy Residential
Plot SubUse Residential Bldg/Apartment
Building Structure Non-Highrise
Building Type Single Detached House
Gross Plot Area 785.70
Deduction from Gross Plot area
- Surrender Free of Cost 32.40
32.40
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 753.30
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 671.24
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 32.40
- Common Plot 82.06
114.46
Balance Plot Area 671.24

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 451.98
Proposed Coverage Area ( 19.07 % ) 143.62
Total Prop. Coverage Area ( 19.07 % ) 143.62
Balance coverage area ( 40.93 % ) 308.36
FAR CHECK
Perm. FAR Area ( 1.50 ) 1178.55
Total Perm. FAR area 1178.55
Residential FAR 273.29
Proposed FAR Area 273.29
Total Proposed FAR Area 273.29
Consumed FAR (Factor) 0.35
Balance FAR Area 905.26
BUA CHECK
Total Proposed BuiltUp Area 273.29


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 4.5 4.50
Proposed Road Width as per Master Plan 4.5 -
Road Widening Width 0 1.20
Plot size (as per measurement) 785.7 785.70




[-] Plot Level Checking (Table 3)

[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 75.33 82.06 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 82.06 0.00 0.00 - 5.78 - 54.26 No Access Provided OK




[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 13 OK





[-] Building Details (Table 4)

[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (SRI THEODORE BAXLA) Residential Residential Bldg/Apartment Non-Highrise



[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (SRI THEODORE BAXLA) 10.00 6.10 6.10 6.10 OK




[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Status
Reqd Perm Prop
A (SRI THEODORE BAXLA) First Floor 2.75 - 3.00 OK
Ground Floor 2.75 - 3.10 OK
Plinth 0.45 - 0.60 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (SRI THEODORE BAXLA) Terrace Floor 1.00 1.20 1.07 OK


[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (SRI THEODORE BAXLA) G + 2 2 - 1 OK


[-] Coverage Check (Table 4b)
Permissible Proposed Status
451.98 143.62 OK
60% 19.07%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
A-1 (SRI THEODORE BAXLA) - 143.62
Total Prop. Coverage Area - 143.62
Total Coverage Area 451.98 143.62


[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
A (SRI THEODORE BAXLA) 1 273.29 273.29 273.29 273.29 01
Grand Total : 1 273.29 273.29 273.29 273.29 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (SRI THEODORE BAXLA)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 143.62 143.62 143.62 143.62
First Floor 129.67 129.67 129.67 129.67
Terrace Floor 0.00 0.00 0.00 0.00
Total : 273.29 273.29 273.29 273.29


[-] UnitBUA Table for Building :A (SRI THEODORE BAXLA) UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT A FLAT 213.20 212.78 10 1
FIRST FLOOR PLAN SPLIT A FLAT 0.00 0.00 10 0
Total: - - 213.20 212.78 20 1


[-] Building :A (SRI THEODORE BAXLA)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
Ground Floor 143.62 143.62 143.62 143.62 01
First Floor 129.67 129.67 129.67 129.67 00
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 273.29 273.29 273.29 273.29 01
Total Number of Same Buildings : 1
Total : 273.29 273.29 273.29 273.29 01

[-] Table 4c-2

FARArea
Building FAR Area : 273.29
Existing FAR Area : 0.00
Perm.
1178.55
Prop.
273.29
Status
OK





[-] Margin Checks (Table 5)
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (SRI THEODORE BAXLA) ROAD WIDENING AREA(SURRENDERED FREE OF COST) 3.00 4.00 1.80 9.85 1.50 3.00 1.50 9.23 OK


[-] BldgLine Margin (Table 5a-1)
Building/Wing Front Side Reqd. Prop. Main Road Name ResvRoad Name Reqd. Width Prop. Width Status
A-1 (SRI THEODORE BAXLA) BldgLine for 4.50 M WIDE ROAD Access Road 0.80 5.20 4.50 M WIDE ROAD Access Road ROAD WIDENING AREA(SURRENDERED FREE OF COST) 0.80 1.20 Ok






[-] Inner Building Details (Table 6)


No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.



[-] Parking Details (Table 7)


NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Residential Bldg/Apartment, In Building: A (SRI THEODORE BAXLA)



[-] Exemption Details (Table 8)



Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (SRI THEODORE BAXLA)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.750 1.050 0.225 0.250 0.200 0.129 - 12 - - 0.000 OK
FIRST FLOOR PLAN STAIRCASE 0.750 1.050 0.225 0.250 0.200 0.125 - 12 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.050 - 0.250 - 0.000 - 0 2.100 - 2.500 OK



[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Sewage Treatment Plant - - 0.98 - - 0.93 - - 1.06 - - 0.00 OK
RAIN WATER HARVESTING - - 2.00 - - 1.06 - - 1.89 - - 0.00 OK
ENT.GATE - - 4.18 - - 0.63 - - 6.61 - - 0.00 OK
SOLAR HEATING SYSTEM - - 1.38 - - 1.06 - - 1.31 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (SRI THEODORE BAXLA) Rain Water Harvesting 1 - 1 OK




[-] Floor Details (Table 9)


[-] Building:A (SRI THEODORE BAXLA)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:FIRST FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.





[-] Summary (Table 10)

Name Perm./Reqd. Proposed Status
Plot Area - 753.30 OK
Plot Width - 28.66 OK
Plot Depth - 26.28 OK
Access Width - 4.50 OK
Plot Frontage - 27.00 OK
Coverage Area 451.98 143.62 OK
FARArea
Bldg. FAR Area : 273.29
Sanctioned FAR Area : 0.00
1178.55 273.29 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In New Area, FAR for plot which lies on road less than 6.10 m. the width shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In New Area, FAR for plot which lies on road less than 6.10 m. the width shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 21-27 mt. and Plot width 27-33 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and 1.5 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Upto 100 mt. shall be 6.1 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road Upto 100 mt. shall be 6.1 mt. {As per Rule No. 34 Table No. 6}
Building Level
Building Height In New Area, for plot which lies on road less than 6.10 m. Perm. Building Ht. shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number In New Area, for plot which lies on road less than 6.10 m. Perm. No of Floor shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
Building Level (Rooms)