No Image Found

Check List Report

Simdega Nagar Panchayat

Version Number: 1.0.30
Version Date: 30/06/2018
Report Generated On: 07-12-2018

[-] Collapse All


General Details
Region JHARKHAND URBAN LOCAL BODIES
District SIMDEGA
Authority SIMDEGA NAGAR PANCHAYAT
Inward_No SINPC/BP/0084/W02/2018
Application Type General Proposal
Project Type Building Permission
Nature of Development New
Location of Development Area Old Area
City Area/TPScheme No NA
Village Gotra
Taluka 36
Architect Details
Architect Name RAJESH KUMAR
License No. SINPC/DFTMN/0006/2017
Architect Address SALDEGA MUNDA TOLI
Architect EmailID rajconsultancy.401@rediffmail.com
Architect Mobile No 9386222833
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No 4975
North -
South -
East -
West -
Owner's Details
Name MAGRITA TOPPO
Address GOTRA THAKURTOLI
Email ID rajconsultancy.401@rediffmail.com
Mobile No 9835580445
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 809.10
2 Plot area as per Document by Applicant 809.10
3 Area as per Site Visit (Site Visit Report) 809.10
4 Area as per Drawing 809.10

Area of Plot Considered : 809.10

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
Unit Meters
Development Detail :
Plot PLOT
Plot Occupancy Residential
Plot SubUse Residential Bldg/Apartment
Building Structure Non-Highrise
Building Type Single Detached House
Gross Plot Area 809.10
Deduction from Gross Plot area
- Surrender Free of Cost 63.22
63.22
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 745.88
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 566.84
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 63.22
- Common Plot 179.03
242.26
Balance Plot Area 566.84

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 447.53
Proposed Coverage Area ( 20.88 % ) 155.72
Total Prop. Coverage Area ( 20.88 % ) 155.72
Balance coverage area ( 39.12 % ) 291.81
FAR CHECK
Perm. FAR Area ( 1.20 ) 970.92
Total Perm. FAR area 970.92
Residential FAR 299.64
Proposed FAR Area 299.64
Total Proposed FAR Area 299.64
Consumed FAR (Factor) 0.37
Balance FAR Area 671.28
BUA CHECK
Total Proposed BuiltUp Area 311.44


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 300 meter and upto 400 meter -
Existing Road Width 3 3.00
Proposed Road Width as per Master Plan 4 -
Road Widening Width 0 2.50
Plot size (as per measurement) 809.1 809.10


Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 745.88 OK
Plot Width Sq.Mt. - - 25.29 OK
Plot Depth Sq.Mt. - - 29.49 OK
Access Width Sq.Mt. - - 3.00 OK
Plot Frontage Sq.Mt. - - 25.29 OK
Coverage Area Sq.Mt. - 447.53 155.72 OK
FAR Area Sq.Mt. - 970.92 299.64 OK
Consumed FAR Sq.Mt. - 1.20 0.37 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 74.59 179.03 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 179.03 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 7.60 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 12 OK
Car In Area Sq.Mt. - - 37.50 OK
Total Car In Area Sq.Mt. 25.00 - 37.50 OK
Visitor's Car Parking In Area Sq.Mt. 12.50 - 25.00 OK
TwoWheeler In Area Sq.Mt. 4.00 - 8.00 OK
Other Parking In Area Sq.Mt. - - 106.18 OK
MAGRITA TOPPO-1 (A1) Front Margin... ROAD WIDENING AREA(SURRENDERED FREE OF COST) Mt. 4.00 - 8.54 OK
Rear Margin Mt. 2.50 - 9.40 OK
Side1 Margin Mt. 1.50 - 5.77 OK
Side2 Margin Mt. 1.50 - 5.50 OK
MAGRITA TOPPO-1 (A1) BldgLine for 3.0 M WIDE ROAD Mt. 2.25 11.04 OK
MAGRITA TOPPO-1 (A1) ResvRoad Width Check for... 3.0 M WIDE ROAD Mt. 2.25 2.50 OK

Building Related Details
Name Description Unit Reqd Perm Proposed Status
MAGRITA TOPPO (A1) First Floor - Height Mt. 2.75 - 3.05 OK
Ground Floor - Height Mt. 2.75 - 3.05 OK
Plinth - Height Mt. 0.45 - 0.76 OK
MAGRITA TOPPO (A1) Terrace Floor - Height Mt. 1.00 1.20 1.07 OK
MAGRITA TOPPO (A1) No. of Floors No. G + 1 2 OK
No. of Tenements No. - 2 OK
GROUND FLOOR PLAN STAIRE CASE - Flight Width Mt. 0.750 1.067 OK
STAIRE CASE - Tread Width Mt. 0.225 0.254 OK
STAIRE CASE - Riser Height Mt. 0.200 0.152 OK
STAIRE CASE - Riser No. On Flight No. - 10 OK
STAIRE CASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRE CASE - Flight Width Mt. 0.750 1.067 OK
STAIRE CASE - Tread Width Mt. 0.225 0.254 OK
STAIRE CASE - Riser Height Mt. 0.200 0.152 OK
STAIRE CASE - Riser No. On Flight No. - 10 OK
STAIRE CASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRE CASE - Flight Width Mt. - 1.067 OK
STAIRE CASE - Tread Width Mt. - 0.254 OK
STAIRE CASE - Riser Height Mt. - - OK
STAIRE CASE - Riser No. On Flight No. - - OK
STAIRE CASE - Cabin Ht. Mt. 2.100 - 2.591 OK
RAIN WATER HARVESTING Area Sq.Mt. - - 27.72 OK
Width Mt. - - 3.83 OK
Depth Mt. - - 7.24 OK
Height Mt. - - - OK
MAGRITA TOPPO (A1) Rain Water Harvesting - No No. 1 - 1 OK


[-] Building:MAGRITA TOPPO (A1)


[-] Floor:GROUND FLOOR PLAN

[-] Misc Checks (Table 9a)
Tnmt No. Room Name Area Width Depth Ventilation Status
Reqd Prop Reqd Prop Reqd Prop Reqd Prop
SPLIT 1 LIVING/DINING 4.62X4.57 9.50 21.14 2.40 4.57 2.40 4.62 2.11 0.00 Failed

[-] Floor:FIRST FLOOR PLAN

[-] Misc Checks (Table 9a)
Tnmt No. Room Name Area Width Depth Ventilation Status
Reqd Prop Reqd Prop Reqd Prop Reqd Prop
SPLIT 2 LIVING/DINING 4.62X4.57 9.50 21.14 2.40 4.57 2.40 4.62 2.11 0.00 Failed






[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth less than 3.60 mt., the Floor Area Ratio-FAR shall be 1.2 {As per Rule No.39, Table 15, Note i}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth less than 3.60 mt., the Floor Area Ratio-FAR shall be 1.2 {As per Rule No.39, Table 15, Note i}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 27-33 mt. and Plot width 21-27 mt., Margin required in Front shall be 4.0 mt., Rear 2.5 mt. and 1.5 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Exceeding 300 mt. shall be 7.50 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 300 mt. shall be 7.50 mt. {As per Rule No. 34 Table No. 6}
Building Level
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width upto 3.6 mt. only G+1 floors shall be allowed {As per Rule No. 39.1 Note 1}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
Accessory Use Number Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
Building Level (Rooms)