No Image Found   

Detail Scrutiny Report

Simdega Nagar Panchayat

Version Number: 1.0.46  
Version Date: 22/06/2020 
Report Generated On: 04-07-2020 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictSIMDEGA
AuthoritySIMDEGA NAGAR PANCHAYAT
Inward_NoSINPC/BP/0137/W14/2019
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageSaldega
Taluka36
Architect Details
Architect NameRAJESH KUMAR
License No.SINPC/DFTMN/0006/2017
Architect AddressSALDEGA MUNDA TOLI
Architect EmailIDrajconsultancy.401@rediffmail.com
Architect Mobile No9386222833
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No712
North -
South -
East -
West -
Owner's Details
NamePUSHPA LAKRA
AddressKUNJ NAGAR
Email IDrajconsultancy.401@rediffmail.com
Mobile No7250246368
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Plot area as per Document by Applicant 341.14
2 Physical area measured at site 341.14
3 Area as per Site Visit (Site Visit Report) 341.14
4Area as per Drawing 341.14

Area of Plot Considered : 341.14

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 341.14
Deduction from Gross Plot area
- Surrender Free of Cost 6.65
6.65
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 334.49
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 313.64
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 6.65
- Common Plot 20.85
27.50
Balance Plot Area 313.64

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 200.69
Proposed Coverage Area ( 57.77 % ) 193.24
Total Prop. Coverage Area ( 57.77 % ) 193.24
Balance coverage area ( 2.23 % ) 7.45
FAR CHECK
Perm. FAR Area ( 1.20 ) 409.37
Total Perm. FAR area 409.37
Residential FAR 191.43
Proposed FAR Area 191.43
Total Proposed FAR Area 191.43
Consumed FAR (Factor) 0.56
Balance FAR Area 217.94
BUA CHECK
Total Proposed BuiltUp Area 193.24


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 3 3.00
Proposed Road Width as per Master Plan 0 -
Road Widening Width 1.52 0.64
Plot size (as per measurement) 341.14 341.14


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 16.72 20.85 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 20.85 0.00 0.00 - 2.19 - 90.00 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 6 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
B (RESIDENTIAL BUILDING) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height (From GL) Height (From Street LVL) Status
B (RESIDENTIAL BUILDING) 3.35 3.35 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
B (RESIDENTIAL BUILDING) Ground Floor 2.75 - 3.35 2.75 - 3.23 2.40 - 3.10 OK
Plinth 0.45 - 0.61 - - 0.61 - - 0.61 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
B (RESIDENTIAL BUILDING) Terrace Floor 1.00 1.20 1.00 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
B (RESIDENTIAL BUILDING) G + 1 1 - 2 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
200.69 193.24 OK
60% 57.77%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  B-1 (RESIDENTIAL BUILDING) - 193.24
  Total Prop. Coverage Area - 193.24
  Total Coverage Area 200.69 193.24

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Void Resi.
B (RESIDENTIAL BUILDING) 1 193.24 1.81 191.43 191.43 191.43 02
Grand Total : 1 193.24 1.81 191.43 191.43 191.43 02


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
B (RESIDENTIAL BUILDING)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 193.24 191.43 193.24 191.43
Terrace Floor 0.00 0.00 0.00 0.00
Total : 193.24 191.43 193.24 191.43


[-] UnitBUA Table for Building :B (RESIDENTIAL BUILDING)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN flat1 FLAT 49.14 48.21 5 2
flat2 FLAT 104.28 102.88 10
Total: - - 153.42 151.09 15 2


[-] Building :B (RESIDENTIAL BUILDING)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Void Resi.
Ground Floor 193.24 1.81 191.43 191.43 191.43 02
Terrace Floor 0.00 0.00 0.00 0.00 0.00 00
Total : 193.24 1.81 191.43 191.43 191.43 02
Total Number of Same Buildings : 1
Total : 193.24 1.81 191.43 191.43 191.43 02
[-] Table 4c-2

  FAR Area
Building FAR Area:191.43
Existing FAR Area :0.00
Perm.
409.37
Prop.
191.43
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
B-1 (RESIDENTIAL BUILDING) ROAD WIDENING AREA(SURRENDERED FREE OF COST) 4.00 5.39 2.50 2.50 0.90 1.22 0.90 1.22 OK


[-] BldgLine Margin (Table 5a-1)
Building/Wing Front Side Reqd. Prop. Main Road Name ResvRoad Name Reqd. Width Prop. Width Status
B-1 (RESIDENTIAL BUILDING) BldgLine for 3.0 M WIDE MAIN ROAD 0.30 6.03 3.0 M WIDE MAIN ROAD ROAD WIDENING AREA(SURRENDERED FREE OF COST) 0.30 0.64 Ok





[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car Visitors Car
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
B (RESIDENTIAL BUILDING) Residential Bungalow/ Dwelling / Non Apartment > 0 1 2.00 1 2 - - - -
> 0 1 2.00 - - - 1 1 -
Total : - - - - 2 3 - 1 1

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 3 37.50 OK
Total Car 2 25.00 3 37.50 OK
Visitor's Car Parking - - 1 12.50 OK
Total Visitor Parking 1 12.50 1 12.50 OK
Total 37.50 62.50 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

Driveway Parking Checks (Table 7d)
Plot Level Parking Driveway is as per the Rules
Floor Level Parking Driveway is as per the Rules
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :B (RESIDENTIAL BUILDING)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.750 1.067 0.225 0.254 0.200 0.168 - 8 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.067 - 0.254 - 0.000 - 0 2.100 - 2.565 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
RAIN WATER HARVESTING - - 1.51 - - 0.74 - - 2.06 - - 0.00 OK
ENT.GATE - - 0.01 - - 0.06 - - 0.20 - - 0.00 OK
SOLAR HEATING SYSTEM - - 0.81 - - 0.66 - - 1.23 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
B (RESIDENTIAL BUILDING) Rain Water Harvesting 1 - 1 OK
Solar Water Heating System 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:B (RESIDENTIAL BUILDING)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 334.49 OK
  Plot Width - 10.36 OK
  Plot Depth - 32.28 OK
  Access Width - 3.00 OK
  Plot Frontage - 10.36 OK
  Coverage Area 200.69 193.24 OK
  FAR Area
Bldg. FAR Area : 191.43
Sanctioned FAR Area :0.00
409.37 191.43 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth less than 3.60 mt., the Floor Area Ratio-FAR shall be 1.2 {As per Rule No.39, Table 15, Note i}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth less than 3.60 mt., the Floor Area Ratio-FAR shall be 1.2 {As per Rule No.39, Table 15, Note i}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 27-33 mt. and Plot width 10-15 mt., Margin required in Front shall be 4.0 mt., Rear 2.5 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road upto 50 mt. shall be 3.6 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road upto 50 mt. shall be 3.6 mt. {As per Rule No. 34 Table No. 6}
Building Level
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width upto 3.6 mt. only G+1 floors shall be allowed {As per Rule No. 39.1 Note 1}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) No need to check distance from Building ENT.GATE
(4) -
(5) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) For Individual residential buildings having more than 150 sq m. plinth area, Provisions of Solar Water Heating System shall be done Solar Water Heating System
Building Level (Rooms)