-
No Image Found   

Check List Report

Simdega Nagar Panchayat

Version Number: 1.0.44  
Version Date: 29/04/2019 
Report Generated On: 21-05-2020 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictSIMDEGA
AuthoritySIMDEGA NAGAR PANCHAYAT
Inward_NoSINPC/BP/0167/W04/2020
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageSaldega
Taluka36
Architect Details
Architect NameRAJESH KUMAR
License No.SINPC/DFTMN/0006/2017
Architect AddressSALDEGA MUNDA TOLI
Architect EmailIDrajconsultancy.401@rediffmail.com
Architect Mobile No9386222833
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No538
North -
South -
East -
West -
Owner's Details
NameJOSEPHIN TOPPO
AddressSALDEGA KHAS
Email IDjosephinetopposo@gmail.com
Mobile No9162172137
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Plot area as per Document by Applicant 394.53
2 Physical area measured at site 394.53
3 Area as per Site Visit (Site Visit Report) 394.53
4Area as per Drawing 391.88

Area of Plot Considered : 391.88

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 391.88
Deduction from Gross Plot area
- Surrender Free of Cost 21.68
21.68
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 370.20
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 329.47
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 21.68
- Common Plot 40.73
62.41
Balance Plot Area 329.47

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 222.12
Proposed Coverage Area ( 33.65 % ) 124.56
Total Prop. Coverage Area ( 33.65 % ) 124.56
Balance coverage area ( 26.35 % ) 97.56
FAR CHECK
Perm. FAR Area ( 1.20 ) 470.26
Total Perm. FAR area 470.26
Residential FAR 124.56
Proposed FAR Area 124.56
Total Proposed FAR Area 124.56
Consumed FAR (Factor) 0.32
Balance FAR Area 345.70
BUA CHECK
Total Proposed BuiltUp Area 124.56


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 3 3.00
Proposed Road Width as per Master Plan 0 -
Road Widening Width 1.52 1.52
Plot size (as per measurement) 394.53 391.88

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 370.20 OK
Plot Width Mt. - - 14.22 OK
Plot Depth Mt. - - 26.03 OK
Access Width Mt. - - 3.00 OK
Plot Frontage Mt. - - 14.22 OK
Coverage Area Sq.Mt. - 222.12 124.56 OK
FAR Area Sq.Mt. - 470.26 124.56 OK
Consumed FAR Sq.Mt. - 1.20 0.32 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 18.51 40.73 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 40.73 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 3.71 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 8 OK
A1-1 (RESIDENCE) Front Margin... ROAD WIDENING AREA(SURRENDERED FREE OF COST) Mt. 3.00 - 7.30 OK
Rear Margin Mt. 1.80 - 7.80 OK
Side1 Margin Mt. 0.90 - 1.00 OK
Side2 Margin Mt. 0.90 - 1.00 OK
A1-1 (RESIDENCE) BldgLine for 3.0 M WIDE MAIN ROAD Mt. 1.05 8.83 OK
A1-1 (RESIDENCE) ResvRoad Width Check for... 3.0 M WIDE MAIN ROAD Mt. 1.05 1.52 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A1 (RESIDENCE) Ground Floor - Height Mt. 2.75 - 3.35 OK
Ground Floor - Clear Height Mt. 2.75 - 3.23 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 3.10 OK
Plinth - Height Mt. 0.45 - 0.61 OK
Plinth - Clear Height Mt. - - 0.61 OK
Plinth - Beam Clear Height Mt. - - 0.61 OK
A1 (RESIDENCE) Terrace Floor - Height Mt. 1.00 1.20 1.01 OK
A1 (RESIDENCE) No. of Floors No. G + 1 1 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 0.991 OK
STAIRCASE - Tread Width Mt. 0.225 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.168 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 0.991 OK
STAIRCASE - Tread Width Mt. - 0.254 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. 2.100 - 2.565 OK
RAIN WATER HARVESTING Area Sq.Mt. - - 6.17 OK
Width Mt. - - 2.13 OK
Depth Mt. - - 2.90 OK
Height Mt. - - - OK
A1 (RESIDENCE) Rain Water Harvesting - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth less than 3.60 mt., the Floor Area Ratio-FAR shall be 1.2 {As per Rule No.39, Table 15, Note i}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth less than 3.60 mt., the Floor Area Ratio-FAR shall be 1.2 {As per Rule No.39, Table 15, Note i}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 21-27 mt. and Plot width 10-15 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Exceeding 50 mt. and upto 100 mt. shall be 5.1 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 50 mt. and upto 100 mt. shall be 5.1 mt. {As per Rule No. 34 Table No. 6}
Building Level
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width upto 3.6 mt. only G+1 floors shall be allowed {As per Rule No. 39.1 Note 1}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
Accessory Use Number Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
Building Level (Rooms)