-
No Image Found   

Detail Scrutiny Report

Simdega Nagar Panchayat

Version Number: 1.0.62  
Version Date: 16/10/2020 
Report Generated On: 19-02-2022 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictSIMDEGA
AuthoritySIMDEGA NAGAR PANCHAYAT
Inward_NoSINPC/BP/0221/W03/2021
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaNew Area
City Area/TPScheme NoNA
VillageGotra
Taluka36
Architect Details
Architect NameMD RAGIB SAYEED
License No.SINPC/ENG/0001/2017
Architect AddressC/o Md. Ragib Sayeed, Opposite Gulzar Gali, Main Road Simdega.
Architect EmailIDragibsanu@gmail.com
Architect Mobile No7070131170
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No4737/4738
North -
South -
East -
West -
Owner's Details
NameGLORIA SUSANA TETE
AddressGOTRA BHUNDUTOLI
Email IDthecreationjh@gmail.com
Mobile No7091111263
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 364.35
2 Plot area as per Document by Applicant 416.32
3 Physical area measured at site 416.32
4 Area as per Site Visit (Site Visit Report) 416.32
5Area as per Drawing 416.32

Area of Plot Considered : 364.35

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 364.35
Deduction from Gross Plot area
- Surrender Free of Cost 16.26
16.26
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 348.09
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 292.26
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 16.26
- Common Plot 55.82
72.09
Balance Plot Area 292.26

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 208.85
Proposed Coverage Area ( 44.31 % ) 154.24
Total Prop. Coverage Area ( 44.31 % ) 154.24
Balance coverage area ( 15.69 % ) 54.61
FAR CHECK
Perm. FAR Area ( 1.50 ) 546.53
Total Perm. FAR area 546.53
Residential FAR 509.13
Proposed FAR Area 509.13
Total Proposed FAR Area 509.13
Consumed FAR (Factor) 1.40
Balance FAR Area 37.40
BUA CHECK
Total Proposed BuiltUp Area 509.14


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 3.6 3.60
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 4.05
Plot size (as per measurement) 416.32 416.32
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land 51.97 52.72 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 17.40 55.82 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 55.82 0.00 0.00 - 4.38 - 90.00 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 10 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (GLORIA SUSANNA TETE) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (GLORIA SUSANNA TETE) 10.00 9.30 9.30 9.30 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (GLORIA SUSANNA TETE) Second Floor 2.75 - 3.10 2.75 - 3.02 2.40 - 2.86 OK
First Floor 2.75 - 3.10 2.75 - 3.02 2.40 - 2.86 OK
Ground Floor 2.75 - 3.10 2.75 - 3.02 2.40 - 2.86 OK
Plinth 0.45 - 0.60 - - 0.60 - - 0.60 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (GLORIA SUSANNA TETE) Terrace Floor - - 1.07 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (GLORIA SUSANNA TETE) G + 2 3 - 1 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
208.85 154.24 OK
60% 44.31%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (GLORIA SUSANNA TETE) - 154.24
  Total Prop. Coverage Area - 154.24
  Total Coverage Area 208.85 154.24

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
A (GLORIA SUSANNA TETE) 1 509.14 509.14 509.14 509.14 01
Grand Total : 1 509.14 509.14 509.14 509.14 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (GLORIA SUSANNA TETE)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 154.24 154.24 154.24 154.24
First Floor 177.45 177.45 177.45 177.45
Second Floor 177.45 177.45 177.45 177.45
Terrace Floor 0.00 0.00 0.00 0.00
Total : 509.14 509.14 509.14 509.14


[-] UnitBUA Table for Building :A (GLORIA SUSANNA TETE)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT A FLAT 437.74 436.59 9 1
FIRST FLOOR PLAN SPLIT A FLAT 0.00 0.00 13 0
SECOND FLOOR PLAN SPLIT A FLAT 0.00 0.00 6 0
SPLIT A FLAT 0.00 0.00 7
Total: - - 437.74 436.59 35 1


[-] Building :A (GLORIA SUSANNA TETE)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
Ground Floor 154.24 154.24 154.24 154.24 01
First Floor 177.45 177.45 177.45 177.45 00
Second Floor 177.45 177.45 177.45 177.45 00
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 509.14 509.14 509.14 509.14 01
Total Number of Same Buildings : 1
Total : 509.14 509.14 509.14 509.14 01
[-] Table 4c-2

  FAR Area
Building FAR Area:509.13
Existing FAR Area :0.00
Perm.
546.53
Prop.
509.13
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (GLORIA SUSANNA TETE) ROAD WIDENING AREA(SURRENDERED FREE OF COST) 3.00 5.05 1.80 6.69 0.90 1.50 0.90 1.20 OK


[-] BldgLine Margin (Table 5a-1)
Building/Wing Front Side Reqd. Prop. Main Road Name ResvRoad Name Reqd. Width Prop. Width Status
A-1 (GLORIA SUSANNA TETE) BldgLine for 3.60 MTR WIDE ROAD Access Road 1.25 10.35 3.60 MTR WIDE ROAD Access Road ROAD WIDENING AREA(SURRENDERED FREE OF COST) 1.25 1.25 Ok





[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/ Dwelling / Non Apartment, In Building: A (GLORIA SUSANNA TETE)
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (GLORIA SUSANNA TETE)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN Staircase -3FL 0.900 0.900 0.250 0.250 0.200 0.100 - 7 - - 0.000 OK
FIRST FLOOR PLAN Staircase -3FL 0.900 0.900 0.250 0.250 0.200 0.100 - 7 - - 0.000 OK
SECOND FLOOR PLAN Staircase -3FL 0.900 0.900 0.250 0.250 0.200 0.100 - 7 - - 0.000 OK
TERRACE FLOOR PLAN Staircase -3FL - 0.900 - 0.250 - 0.000 - 0 - - 2.530 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Sewage Treatment Plant - - 0.94 - - 0.82 - - 1.15 - - 0.00 OK
RAIN WATER HARVESTING - - 1.26 - - 0.80 - - 1.58 - - 0.00 OK
ENT.GATE - - 0.64 - - 0.36 - - 1.77 - - 0.00 OK
SOLAR HEATING SYSTEM - - 1.21 - - 0.80 - - 1.51 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (GLORIA SUSANNA TETE) Rain Water Harvesting 1 - 1 OK
Solar Water Heating System 1 - 1 OK
Entrance Gate 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (GLORIA SUSANNA TETE)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:FIRST FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:SECOND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 348.09 OK
  Plot Width - 13.01 OK
  Plot Depth - 26.70 OK
  Access Width - 3.60 OK
  Plot Frontage - 13.01 OK
  Coverage Area 208.85 154.24 OK
  FAR Area
Bldg. FAR Area : 509.13
Sanctioned FAR Area :0.00
546.53 509.13 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In New Area, FAR for plot which lies on road less than 6.10 m. the width shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In New Area, FAR for plot which lies on road less than 6.10 m. the width shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 21-27 mt. and Plot width 10-15 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Upto 100 mt. shall be 6.1 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road Upto 100 mt. shall be 6.1 mt. {As per Rule No. 34 Table No. 6}
Building Level
Building Height In New Area, for plot which lies on road less than 6.10 m. Perm. Building Ht. shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number In New Area, for plot which lies on road less than 6.10 m. Perm. No of Floor shall be taken as incase of Old Area {As per Addendum from Govt. of Jharkhand 3141 dated 15/05/2017}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) For Individual residential buildings having more than 150 sq m. plinth area, Provisions of Solar Water Heating System shall be done Solar Water Heating System
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)