No Image Found   

Detail Scrutiny Report

Simdega Nagar Panchayat

Version Number: 1.0.61  
Version Date: 16/10/2020 
Report Generated On: 15-12-2021 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictSIMDEGA
AuthoritySIMDEGA NAGAR PANCHAYAT
Inward_NoSINPC/BP/0208/W06/2021
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageKhijri
Taluka36
Architect Details
Architect NameMD RAGIB SAYEED
License No.SINPC/ENG/0001/2017
Architect AddressC/o Md. Ragib Sayeed, Opposite Gulzar Gali, Main Road Simdega.
Architect EmailIDragibsanu@gmail.com
Architect Mobile No7070131170
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No2650
North -
South -
East -
West -
Owner's Details
NamePRABHAT DUNGDUNG
AddressKHIJRI MAHTOTOLI
Email IDragibsanu@gmail.com
Mobile No8797016862
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 283.38
2 Plot area as per Document by Applicant 280.39
3 Physical area measured at site 280.39
4 Area as per Site Visit (Site Visit Report) 280.39
5Area as per Drawing 280.39

Area of Plot Considered : 280.39

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 280.39
Deduction from Gross Plot area
- Surrender Free of Cost 13.20
13.20
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 267.20
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 230.62
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 13.20
- Common Plot 36.58
49.77
Balance Plot Area 230.62

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 160.32
Proposed Coverage Area ( 43.66 % ) 116.65
Total Prop. Coverage Area ( 43.66 % ) 116.65
Balance coverage area ( 16.34 % ) 43.67
FAR CHECK
Perm. FAR Area ( 1.50 ) 420.59
Total Perm. FAR area 420.59
Residential FAR 233.30
Proposed FAR Area 233.30
Total Proposed FAR Area 233.30
Consumed FAR (Factor) 0.83
Balance FAR Area 187.29
BUA CHECK
Total Proposed BuiltUp Area 233.30


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 3.6 3.60
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 1.00
Plot size (as per measurement) 280.39 280.39
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 13.36 36.58 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 36.58 0.00 0.00 - 3.74 - 90.00 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 10 OK
   
   
   
    [-] Building Miscellanies Checks

Building Sr. No. Remarks Required/Permissible Proposed Status
A (PRABHAT DUNDUNG) 1 WINDOW should not intersect/outside the Plot at Ground Floor Plan in A (PRABHAT DUNDUNG) Building. 0 0 Failed
2 WINDOW should not intersect/outside the Plot at Ground Floor Plan in A (PRABHAT DUNDUNG) Building. 0 0 Failed
3 WINDOW should not intersect/outside the Plot at Ground Floor Plan in A (PRABHAT DUNDUNG) Building. 0 0 Failed
4 WINDOW should not intersect/outside the Plot at Ground Floor Plan in A (PRABHAT DUNDUNG) Building. 0 0 Failed
5 WINDOW should not intersect/outside the Plot at Ground Floor Plan in A (PRABHAT DUNDUNG) Building. 0 0 Failed
6 WINDOW should not intersect/outside the Plot at Ground Floor Plan in A (PRABHAT DUNDUNG) Building. 0 0 Failed
7 ROOM should not intersect/outside the Plot at Ground Floor Plan in A (PRABHAT DUNDUNG) Building. 0 0 Failed
8 ROOM should not intersect/outside the Plot at Ground Floor Plan in A (PRABHAT DUNDUNG) Building. 0 0 Failed
9 ROOM should not intersect/outside the Plot at Ground Floor Plan in A (PRABHAT DUNDUNG) Building. 0 0 Failed
10 ROOM should not intersect/outside the Plot at Ground Floor Plan in A (PRABHAT DUNDUNG) Building. 0 0 Failed
11 ROOM should not intersect/outside the Plot at Ground Floor Plan in A (PRABHAT DUNDUNG) Building. 0 0 Failed
12 CFAR should not intersect/outside the Plot at Ground Floor Plan in A (PRABHAT DUNDUNG) Building. 0 0 Failed
13 FAR should not intersect/outside the Plot at Ground Floor Plan in A (PRABHAT DUNDUNG) Building. 0 0 Failed
14 WINDOW should not intersect/outside the Plot at First Floor Plan in A (PRABHAT DUNDUNG) Building. 0 0 Failed
15 WINDOW should not intersect/outside the Plot at First Floor Plan in A (PRABHAT DUNDUNG) Building. 0 0 Failed
16 WINDOW should not intersect/outside the Plot at First Floor Plan in A (PRABHAT DUNDUNG) Building. 0 0 Failed
17 WINDOW should not intersect/outside the Plot at First Floor Plan in A (PRABHAT DUNDUNG) Building. 0 0 Failed
18 WINDOW should not intersect/outside the Plot at First Floor Plan in A (PRABHAT DUNDUNG) Building. 0 0 Failed
19 WINDOW should not intersect/outside the Plot at First Floor Plan in A (PRABHAT DUNDUNG) Building. 0 0 Failed
20 ROOM should not intersect/outside the Plot at First Floor Plan in A (PRABHAT DUNDUNG) Building. 0 0 Failed
21 ROOM should not intersect/outside the Plot at First Floor Plan in A (PRABHAT DUNDUNG) Building. 0 0 Failed
22 ROOM should not intersect/outside the Plot at First Floor Plan in A (PRABHAT DUNDUNG) Building. 0 0 Failed
23 ROOM should not intersect/outside the Plot at First Floor Plan in A (PRABHAT DUNDUNG) Building. 0 0 Failed
24 ROOM should not intersect/outside the Plot at First Floor Plan in A (PRABHAT DUNDUNG) Building. 0 0 Failed
25 CFAR should not intersect/outside the Plot at First Floor Plan in A (PRABHAT DUNDUNG) Building. 0 0 Failed
26 FAR should not intersect/outside the Plot at First Floor Plan in A (PRABHAT DUNDUNG) Building. 0 0 Failed
27 TERRACE should not intersect/outside the Plot at Terrace Floor Plan in A (PRABHAT DUNDUNG) Building. 0 0 Failed
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (PRABHAT DUNDUNG) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (PRABHAT DUNDUNG) 8.04 6.29 6.29 6.29 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (PRABHAT DUNDUNG) First Floor 2.75 - 3.15 2.75 - 3.05 2.40 - 2.85 OK
Ground Floor 2.75 - 3.15 2.75 - 3.05 2.40 - 2.85 OK
Plinth 0.45 - 0.60 - - 0.60 - - 0.60 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (PRABHAT DUNDUNG) Terrace Floor - - 1.02 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (PRABHAT DUNDUNG) G + 2 2 - 1 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
160.32 116.65 OK
60% 43.66%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (PRABHAT DUNDUNG) - 116.65
  Total Prop. Coverage Area - 116.65
  Total Coverage Area 160.32 116.65

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
A (PRABHAT DUNDUNG) 1 233.30 233.30 233.30 233.30 01
Grand Total : 1 233.30 233.30 233.30 233.30 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (PRABHAT DUNDUNG)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 116.65 116.65 116.65 116.65
First Floor 116.65 116.65 116.65 116.65
Terrace Floor 0.00 0.00 0.00 0.00
Total : 233.30 233.30 233.30 233.30


[-] UnitBUA Table for Building :A (PRABHAT DUNDUNG)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT A FLAT 192.62 192.43 9 1
FIRST FLOOR PLAN SPLIT A FLAT 0.00 0.00 9 0
Total: - - 192.62 192.43 18 1


[-] Building :A (PRABHAT DUNDUNG)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
Ground Floor 116.65 116.65 116.65 116.65 01
First Floor 116.65 116.65 116.65 116.65 00
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 233.30 233.30 233.30 233.30 01
Total Number of Same Buildings : 1
Total : 233.30 233.30 233.30 233.30 01
[-] Table 4c-2

  FAR Area
Building FAR Area:233.30
Existing FAR Area :0.00
Perm.
420.59
Prop.
233.30
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (PRABHAT DUNDUNG) ROAD WIDENING AREA(SURRENDERED FREE OF COST) 2.50 1.64 1.50 3.83 0.90 0.00 0.90 3.78 Failed






[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/ Dwelling / Non Apartment, In Building: A (PRABHAT DUNDUNG)
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (PRABHAT DUNDUNG)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.750 1.072 0.225 0.250 0.200 0.131 - 12 - - 0.000 OK
FIRST FLOOR PLAN STAIRCASE 0.750 1.072 0.225 0.250 0.200 0.131 - 12 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.072 - 0.250 - 0.000 - 0 2.100 - 2.539 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Sewage Treatment Plant - - 0.94 - - 0.81 - - 1.15 - - 0.00 OK
RAIN WATER HARVESTING - - 2.38 - - 1.41 - - 1.69 - - 0.00 OK
ENT.GATE - - 2.47 - - 0.59 - - 4.22 - - 0.00 OK
SOLAR HEATING SYSTEM - - 1.34 - - 1.15 - - 1.16 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (PRABHAT DUNDUNG) Rain Water Harvesting 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (PRABHAT DUNDUNG)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:FIRST FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 267.20 OK
  Plot Width - 13.20 OK
  Plot Depth - 20.25 OK
  Access Width - 3.60 OK
  Plot Frontage - 13.20 OK
  Coverage Area 160.32 116.65 OK
  FAR Area
Bldg. FAR Area : 233.30
Sanctioned FAR Area :0.00
420.59 233.30 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 15-21 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.5 mt., Rear 1.5 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)