No Image Found   

Check List Report

Simdega Nagar Panchayat

Version Number: 1.0.66  
Version Date: 16/10/2020 
Report Generated On: 12-10-2023 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictSIMDEGA
AuthoritySIMDEGA NAGAR PANCHAYAT
Inward_NoSINPC/BP/0262/W05/2021
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageGotra
Taluka36
Architect Details
Architect NameMD RAGIB SAYEED
License No.SINPC/ENG/0001/2017
Architect AddressC/o Md. Ragib Sayeed, Opposite Gulzar Gali, Main Road Simdega.
Architect EmailIDragibsanu@gmail.com
Architect Mobile No7070131170
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No3495
North -
South -
East -
West -
Owner's Details
NameSARASWATI DEVI
AddressGOTRA NAYATOLI, SMATOLI, SIMDEGA
Email IDthecreationjh@gmail.com
Mobile No8797016862
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 404.83
2 Plot area as per Document by Applicant 404.44
3 Physical area measured at site 404.44
4 Area as per Site Visit (Site Visit Report) 404.44
5Area as per Drawing 404.44

Area of Plot Considered : 404.44

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPlot
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 404.44
Deduction from Gross Plot area
- Surrender Free of Cost 20.73
20.73
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 383.71
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 277.36
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 20.73
- Common Plot 106.35
127.08
Balance Plot Area 277.36

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 230.23
Proposed Coverage Area ( 32.27 % ) 123.84
Total Prop. Coverage Area ( 32.27 % ) 123.84
Balance coverage area ( 27.73 % ) 106.39
FAR CHECK
Perm. FAR Area ( 1.500 ) 606.66
Total Perm. FAR area 606.66
Residential FAR 123.84
Proposed FAR Area 123.84
Total Proposed FAR Area 123.84
Consumed FAR (Factor) 0.31
Balance FAR Area 482.82
BUA CHECK
Total Proposed BuiltUp Area 123.84


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 3.6 3.60
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 1.00
Plot size (as per measurement) 404.44 404.44
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 383.71 OK
Plot Width Mt. - - 20.73 OK
Plot Depth Mt. - - 18.51 OK
Access Width Mt. - - 3.60 OK
Plot Frontage Mt. - - 20.73 OK
Coverage Area Sq.Mt. - 230.23 123.84 OK
FAR Area Sq.Mt. - 606.66 123.84 OK
Consumed FAR Sq.Mt. - 1.50 0.31 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 19.19 106.35 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 106.35 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 7.27 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 7 OK
VI-1 (SARASWATI DEVI) Front Margin... ROAD WIDENING AREA(SURRENDERED FREE OF COST) Mt. 2.50 - 2.50 OK
Rear Margin Mt. 1.50 - 5.07 OK
Side1 Margin Mt. 1.00 - 8.41 OK
Side2 Margin Mt. 1.00 - 1.00 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
VI (SARASWATI DEVI) Height Mt. 8.90 3.10 OK
VI (SARASWATI DEVI) Ground Floor - Height Mt. 2.75 - 3.10 OK
Ground Floor - Clear Height Mt. 2.75 - 3.00 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.80 OK
Plinth - Height Mt. 0.45 - 0.60 OK
Plinth - Clear Height Mt. - - 0.30 OK
Plinth - Beam Clear Height Mt. - - 0.30 OK
VI (SARASWATI DEVI) Terrace Floor - Height Mt. - - 0.90 OK
Terrace Floor - Clear Height Mt. - - 0.90 OK
Terrace Floor - Beam Clear Height Mt. - - 0.90 OK
VI (SARASWATI DEVI) No. of Floors No. G + 2 1 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.750 1.050 OK
STAIRCASE - Tread Width Mt. 0.225 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.155 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.050 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. 2.100 - 2.430 OK
Toilet Area Sq.Mt. - 5.00 3.00 OK
Width Mt. - - 1.50 OK
Depth Mt. - - 2.00 OK
Height Mt. - - - OK
SUMP TANK Area Sq.Mt. - - 1.08 OK
Width Mt. - - 0.90 OK
Depth Mt. - - 1.20 OK
Height Mt. - - - OK
Garbage Pit Area Sq.Mt. - - 1.08 OK
Width Mt. - - 0.90 OK
Depth Mt. - - 1.20 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 9.00 OK
Width Mt. - - 3.00 OK
Depth Mt. - - 3.00 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 1.35 OK
Width Mt. - - 0.30 OK
Depth Mt. - - 4.50 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 1.08 OK
Width Mt. - - 0.90 OK
Depth Mt. - - 1.20 OK
Height Mt. - - - OK
VI (SARASWATI DEVI) Rain Water Harvesting - No No. 1 - 1 OK
   
   

[-] Building:VI (SARASWATI DEVI)


[-] Floor:GROUND FLOOR PLAN

[-] Misc Checks (Table 9a)
Tnmt No. Room Name Area Width Depth Ventilation Status
Reqd Prop Reqd Prop Reqd Prop Reqd Prop






[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 15-21 mt. and Plot width 15-21 mt., Margin required in Front shall be 2.5 mt., Rear 1.5 mt. and 1.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building SUMP TANK
(5) -
(6) No need to check distance from Building Garbage Pit
(7) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(8) No need to check distance from Building RAIN WATER HARVESTING
(9) No need to check distance from Building ENT.GATE
(10) -
(11) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)