No Image Found   

Check List Report

Simdega Nagar Panchayat

Version Number: 1.0.65  
Version Date: 16/10/2020 
Report Generated On: 22-02-2023 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictSIMDEGA
AuthoritySIMDEGA NAGAR PANCHAYAT
Inward_NoSINPC/BP/0366/W14/2022
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageSaldega
Taluka36
Architect Details
Architect Namevivek raj gupta
License No.SINPC/ENG/0001/2022
Architect AddressPRINCE CHOWK,SIMDEGA ,JHARKHAND
Architect EmailIDvivekgupta553@gmail.com
Architect Mobile No7008039097
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No877
NorthPlot No. - 877
SouthPlot No. - 877
EastRoad Width - 3.6
WestPlot No. - 877
Owner's Details
NameCHANCHLA DEVI
AddressSANKAR BAGAN,DIPTATOLI SALDEGA
Email IDKUNDANBOLAKPUR90@GMAIL.COM
Mobile No8210308240
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 153.80
2 Plot area as per Document by Applicant 155.52
3 Physical area measured at site 155.52
4 Area as per Site Visit (Site Visit Report) 155.52
5Area as per Drawing 155.52

Area of Plot Considered : 153.80

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 153.80
Deduction from Gross Plot area
- Road Widening Area 14.17
14.17
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 139.63
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 128.04
Deductions for Balance Plot Area (from Gross Plot Area)
- Road Widening Area 14.17
- Common Plot 11.59
25.76
Balance Plot Area 128.04

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 97.74
Proposed Coverage Area ( 54.49 % ) 76.08
Total Prop. Coverage Area ( 54.49 % ) 76.08
Balance coverage area ( 15.51 % ) 21.66
FAR CHECK
Perm. FAR Area ( 1.500 ) 209.45
Total Perm. FAR area 209.45
Residential FAR 228.25
Proposed FAR Area 228.25
Total Proposed FAR Area 228.25
Consumed FAR (Factor) 1.63
Balance FAR Area 0.00
Total Paid Proposed FAR Area 18.80
BUA CHECK
Total Proposed BuiltUp Area 228.24


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 3.6 3.60
Proposed Road Width as per Master Plan 3.6 -
Road Widening Width 2 2.00
Plot size (as per measurement) 155.52 155.52
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land 1.72 0.00 Failed

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area 1.72 - 0.00 Failed

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 139.63 OK
Plot Width Mt. - - 7.09 OK
Plot Depth Mt. - - 19.95 OK
Access Width Mt. - - 3.60 OK
Plot Frontage Mt. - - 7.09 OK
Coverage Area Sq.Mt. - 97.74 76.08 OK
FAR Area Sq.Mt. - 209.45 228.25 Failed
Consumed FAR Sq.Mt. - 1.50 1.63 Failed
Common Plot Checks Common Plot - Total Area Sq.Mt. 6.98 11.59 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 11.59 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 1.69 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 2 4 OK
Car In Area Sq.Mt. - - 12.50 OK
Total Car In Area Sq.Mt. 37.50 - 12.50 Failed
Visitor's Car Parking In Area Sq.Mt. - - 12.50 OK
Total Visitor Parking In Area Sq.Mt. 12.50 - 12.50 OK
DriveWay PLOT - - - DRIVEWAY - Width No. 3.60 - 5.11 OK
A -1 (BUILDING) Front Margin... ROAD WIDENING AREA Mt. 2.50 - 5.55 OK
Rear Margin Mt. 1.50 - 1.90 OK
Side1 Margin Mt. - - 0.00 OK
Side2 Margin Mt. 0.90 - 1.00 OK
A -1 (BUILDING) BldgLine for 3.6 M MAIN ROAD Mt. 1.95 7.55 OK
A -1 (BUILDING) ResvRoad Width Check for... 3.6 M MAIN ROAD Mt. 1.95 2.00 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (BUILDING) Height Mt. 10.00 8.53 OK
A (BUILDING) Second Floor - Height Mt. 2.75 - 2.80 OK
Second Floor - Clear Height Mt. 2.75 - 2.68 Failed
Second Floor - Beam Clear Height Mt. 2.40 - 2.50 OK
First Floor - Height Mt. 2.75 - 2.80 OK
First Floor - Clear Height Mt. 2.75 - 2.68 Failed
First Floor - Beam Clear Height Mt. 2.40 - 2.50 OK
Ground Floor - Height Mt. 2.75 - 2.93 OK
Ground Floor - Clear Height Mt. 2.75 - 2.80 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.63 OK
Plinth - Height Mt. 0.45 - 0.60 OK
Plinth - Clear Height Mt. - - 0.60 OK
Plinth - Beam Clear Height Mt. - - 0.60 OK
A (BUILDING) Terrace Floor - Height Mt. - - 1.00 OK
Terrace Floor - Clear Height Mt. - - 1.00 OK
Terrace Floor - Beam Clear Height Mt. - - 1.00 OK
A (BUILDING) No. of Floors No. G + 2 3 OK
No. of Tenements No. - 3 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.000 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.154 OK
STAIRCASE - Riser No. On Flight No. - 9 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.000 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.147 OK
STAIRCASE - Riser No. On Flight No. - 9 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
SECOND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.000 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.147 OK
STAIRCASE - Riser No. On Flight No. - 9 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.000 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.800 OK
RAIN WATER HARVESTING Area Sq.Mt. - - 5.15 OK
Width Mt. - - 1.61 OK
Depth Mt. - - 3.19 OK
Height Mt. - - - OK
A (BUILDING) Rain Water Harvesting - No No. 1 - 1 OK
   
   

[-] Building:A (BUILDING)


[-] Floor:GROUND FLOOR PLAN

[-] Misc Checks (Table 9a)
Tnmt No. Room Name Area Width Depth Ventilation Status
Reqd Prop Reqd Prop Reqd Prop Reqd Prop

[-] Floor:FIRST FLOOR PLAN

[-] Misc Checks (Table 9a)
Tnmt No. Room Name Area Width Depth Ventilation Status
Reqd Prop Reqd Prop Reqd Prop Reqd Prop

[-] Floor:SECOND FLOOR PLAN

[-] Misc Checks (Table 9a)
Tnmt No. Room Name Area Width Depth Ventilation Status
Reqd Prop Reqd Prop Reqd Prop Reqd Prop






[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 15-21 mt. and Plot width 15-21 mt., Margin required in Front shall be 2.5 mt., Rear 1.5 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Exceeding 300 mt. shall be 7.50 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 300 mt. shall be 7.50 mt. {As per Rule No. 34 Table No. 6}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)