-
No Image Found   

Detail Scrutiny Report

Simdega Nagar Panchayat

Version Number: 1.0.64  
Version Date: 16/10/2020 
Report Generated On: 01-12-2022 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictSIMDEGA
AuthoritySIMDEGA NAGAR PANCHAYAT
Inward_NoSINPC/BP/0345/W02/2022
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageGotra
Taluka36
Architect Details
Architect NameMAHENDRA MEHTA
License No.SINPC/DFTMN/0002/2022
Architect AddressRAJ CONSULTANCY, CLUB COMPLEX ,GANDHI MAIDAN MAIN ROAD SIMDEGA
Architect EmailIDrajconsultancysmd@gmail.com
Architect Mobile No9386222833
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No5057
North -
South -
East -
West -
Owner's Details
NameANJELA DUNGDUNG
AddressTHAKUR TOLI
Email IDtheodorkullu28980@gmail.com
Mobile No7903600203
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Plot area as per Document by Applicant 277.62
2 Physical area measured at site 277.62
3 Area as per Site Visit (Site Visit Report) 277.62
4Area as per Drawing 277.62

Area of Plot Considered : 277.62

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 277.62
Deduction from Gross Plot area
- Surrender Free of Cost 32.01
32.01
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 245.61
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 233.12
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 32.01
- Common Plot 12.49
44.50
Balance Plot Area 233.12

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 147.37
Proposed Coverage Area ( 41.89 % ) 102.89
Total Prop. Coverage Area ( 41.89 % ) 102.89
Balance coverage area ( 18.11 % ) 44.48
FAR CHECK
Perm. FAR Area ( 1.500 ) 416.43
Total Perm. FAR area 416.43
Residential FAR 205.78
Proposed FAR Area 205.78
Total Proposed FAR Area 205.78
Consumed FAR (Factor) 0.74
Balance FAR Area 210.65
BUA CHECK
Total Proposed BuiltUp Area 205.78


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 3.6 3.66
Proposed Road Width as per Master Plan 3.6 -
Road Widening Width 0 1.99
Plot size (as per measurement) 277.62 277.62

[-] Road width Details Checks
No Rule Status
1 For Existing Road Width, value as per site visit and value as per drawing should be same. Failed


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 12.28 12.49 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 12.49 0.00 0.00 - 1.18 - 90.00 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 8 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A1 (RESIDENCE) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A1 (RESIDENCE) 10.00 6.96 6.96 7.25 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A1 (RESIDENCE) First Floor 2.75 - 3.48 2.75 - 3.35 2.40 - 3.23 OK
Ground Floor 2.75 - 3.48 2.75 - 3.36 2.40 - 3.23 OK
Plinth 0.45 - 0.61 - - 0.61 - - 0.61 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A1 (RESIDENCE) Terrace Floor - - 0.92 - - 0.92 - - 0.92 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A1 (RESIDENCE) G + 2 2 - 2 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
147.37 102.89 OK
60% 41.89%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A1-1 (RESIDENCE) - 102.89
  Total Prop. Coverage Area - 102.89
  Total Coverage Area 147.37 102.89

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
A1 (RESIDENCE) 1 205.78 205.78 205.78 205.78 02
Grand Total : 1 205.78 205.78 205.78 205.78 02


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A1 (RESIDENCE)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 102.89 102.89 102.89 102.89
First Floor 102.89 102.89 102.89 102.89
Terrace Floor 0.00 0.00 0.00 0.00
Total : 205.78 205.78 205.78 205.78


[-] UnitBUA Table for Building :A1 (RESIDENCE)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT1 FLAT 80.75 80.61 9 1
FIRST FLOOR PLAN SPLIT2 FLAT 80.72 80.58 9 1
Total: - - 161.47 161.19 18 2


[-] Building :A1 (RESIDENCE)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
Ground Floor 102.89 102.89 102.89 102.89 01
First Floor 102.89 102.89 102.89 102.89 01
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 205.78 205.78 205.78 205.78 02
Total Number of Same Buildings : 1
Total : 205.78 205.78 205.78 205.78 02
[-] Table 4c-2

  FAR Area
Building FAR Area:205.78
Existing FAR Area :0.00
Perm.
416.43
Prop.
205.78
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A1-1 (RESIDENCE) ROAD WIDENING AREA(SURRENDERED FREE OF COST) 2.50 5.51 1.50 1.55 0.90 0.94 0.90 0.94 OK


[-] BldgLine Margin (Table 5a-1)
Building/Wing Front Side Reqd. Prop. Main Road Name ResvRoad Name Reqd. Width Prop. Width Status
A1-1 (RESIDENCE) BldgLine for 3.66 wd. ROAD Access Road 1.92 7.52 3.66 wd. ROAD Access Road ROAD WIDENING AREA(SURRENDERED FREE OF COST) 1.92 2.02 Ok





[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car Visitors Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A1 (RESIDENCE) Residential Bungalow/ Dwelling / Non Apartment > 0 1 2.00 1 2 - - - - - - -
> 0 1 2.00 - - - 1 1 - - - -
Total : - - - - 2 2 - 1 1 - 0 2

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 2 25.86 OK
Total Car 2 25.00 2 25.86 OK
Visitor's Car Parking - - 1 12.85 OK
Total Visitor Parking 1 12.50 1 12.85 OK
TwoWheeler - - 2 8.67 OK
Total TwoWheeler - - 2 8.67 OK
Total 37.50 56.05 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

[-] Driveway Parking Checks (Table 7d)
Building/Plot Name Floor Name Driveway Name Width Status
Reqd Perm Prop
PLOT - DRIVE WAY 3.60 - 4.36 OK

   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A1 (RESIDENCE)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.750 0.914 0.225 0.254 0.200 0.174 - 5 - - 0.000 OK
FIRST FLOOR PLAN STAIRCASE 0.750 0.914 0.225 0.254 0.200 0.174 - 5 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 0.914 - 0.254 - 0.000 - 0 2.100 - 2.565 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
RAIN WATER HARVESTING - - 3.97 - - 1.30 - - 3.06 - - 0.00 OK
ENT.GATE - - 4.98 - - 1.52 - - 3.36 - - 0.00 OK
SOLAR HEATING SYSTEM - - 3.57 - - 1.36 - - 2.63 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A1 (RESIDENCE) Rain Water Harvesting 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A1 (RESIDENCE)


[-] Floor:GROUND FLOOR PLAN

[-] Misc Checks (Table 9a)
Tnmt No. Room Name Area Width Depth Ventilation Status
Reqd Prop Reqd Prop Reqd Prop Reqd Prop
SPLIT1 TOILET 1.93X1.35 2.80 2.60 1.20 1.35 1.20 1.93 0.30 0.73 Failed
DRAWING ROOM 2.58X2.87 7.50 7.35 2.10 2.58 2.40 2.87 0.74 1.83 Failed

[-] Floor:FIRST FLOOR PLAN

[-] Misc Checks (Table 9a)
Tnmt No. Room Name Area Width Depth Ventilation Status
Reqd Prop Reqd Prop Reqd Prop Reqd Prop
SPLIT2 TOILET 2.62X0.99 2.80 2.60 1.20 0.99 1.20 2.62 0.30 0.73 Failed
BED ROOM 3.07X1.93 7.50 5.92 2.10 1.93 2.40 3.07 0.59 3.66 Failed


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 245.61 OK
  Plot Width - 14.00 OK
  Plot Depth - 17.54 OK
  Access Width - 3.66 OK
  Plot Frontage - 16.05 OK
  Coverage Area 147.37 102.89 OK
  FAR Area
Bldg. FAR Area : 205.78
Sanctioned FAR Area :0.00
416.43 205.78 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 15-21 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.5 mt., Rear 1.5 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Exceeding 300 mt. shall be 7.50 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 300 mt. shall be 7.50 mt. {As per Rule No. 34 Table No. 6}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) No need to check distance from Building ENT.GATE
(4) -
(5) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)