Check List Report

Simdega Nagar Panchayat

Version Number: 1.0.66  
Version Date: 16/10/2020 
Report Generated On: 18-04-2023 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictSIMDEGA
AuthoritySIMDEGA NAGAR PANCHAYAT
Inward_NoSINPC/BP/0397/W02/2023
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageGotra
Taluka36
Architect Details
Architect Namevivek raj gupta
License No.SINPC/ENG/0001/2022
Architect AddressPRINCE CHOWK,SIMDEGA ,JHARKHAND
Architect EmailIDvivekgupta553@gmail.com
Architect Mobile No7008039097
Plot Details
Plot Use Medical
Plot SubUse Private Hospital
PlotNearbyReligiousStructure NA
Plot/SubPlot No4733,4684
NorthRoad Width - 3.6
SouthPlot No. - 4684
EastPlot No. - 4684
WestRoad Width - 15
Owner's Details
NameMAMTA KULLU
AddressHELENPUR,BHURU TOLI,SIMDEGA
Email IDbhanu.pratap.sahu11@gmail.com
Mobile No7677753897
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 951.44
2 Plot area as per Document by Applicant 951.44
3 Physical area measured at site 951.02
4 Area as per Site Visit (Site Visit Report) 951.44
5Area as per Drawing 951.44

Area of Plot Considered : 951.02

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
Unit
Development Detail :
Plotplot
Plot OccupancyMedical
Plot SubUse Private Hospital
Building StructureNon-Highrise
Building TypeSpecial Building
Gross Plot Area 951.02
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 951.02
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 898.39
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 52.63
52.63
Balance Plot Area 898.39

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 570.61
Proposed Coverage Area ( 40.27 % ) 382.97
Total Prop. Coverage Area ( 40.27 % ) 382.97
Balance coverage area ( 19.73 % ) 187.64
FAR CHECK
Perm. FAR Area ( 2.000 ) 1902.04
Total Perm. FAR area 1902.04
Special FAR 1170.23
Proposed FAR Area 1170.23
Total Proposed FAR Area 1170.23
Consumed FAR (Factor) 1.23
Balance FAR Area 731.81
BUA CHECK
Total Proposed BuiltUp Area 1238.51


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 15 15.00
Proposed Road Width as per Master Plan 15 -
Road Widening Width 0 -
Plot size (as per measurement) 951.44 951.44
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. 300.00 - 951.02 OK
Plot Width Mt. - - 20.27 OK
Plot Depth Mt. - - 46.94 OK
Access Width Mt. 12.20 - 15.00 OK
Plot Frontage Mt. - - 20.27 OK
Coverage Area Sq.Mt. - 570.61 382.97 OK
FAR Area Sq.Mt. - 1902.04 1170.23 OK
Consumed FAR Sq.Mt. - 2.00 1.23 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 47.55 52.63 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 52.63 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 4.15 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 6 OK
Car In Area Sq.Mt. - - 51.00 OK
Total Car In Area Sq.Mt. 12.50 - 51.00 OK
Visitor's Car Parking In Area Sq.Mt. - - 38.25 OK
Total Visitor Parking In Area Sq.Mt. - - 38.25 OK
DriveWay plot - - - DRIVE WAY - Width No. 3.60 - 12.29 OK
A-1 (BUILDING) Front Margin... 15 M WIDE MAIN ROAD Mt. 8.00 - 15.24 OK
Rear Margin Mt. 5.00 - 5.20 OK
Side1 Margin Mt. 2.50 - 2.60 OK
Side2 Margin Mt. 2.50 - 2.60 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (BUILDING) Height Mt. 30.00 9.00 OK
A (BUILDING) Second Floor - Height Mt. 2.75 - 3.00 OK
Second Floor - Clear Height Mt. 2.75 - 2.85 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.43 OK
First Floor - Height Mt. 2.75 - 3.00 OK
First Floor - Clear Height Mt. 2.75 - 2.85 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.43 OK
Ground Floor - Height Mt. 2.75 - 3.00 OK
Ground Floor - Clear Height Mt. 2.75 - 2.85 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.43 OK
Plinth - Height Mt. 0.45 - 0.60 OK
Plinth - Clear Height Mt. - - 0.60 OK
Plinth - Beam Clear Height Mt. - - 0.60 OK
A (BUILDING) Terrace Floor - Height Mt. - - 1.00 OK
Terrace Floor - Clear Height Mt. - - 1.00 OK
Terrace Floor - Beam Clear Height Mt. - - 1.00 OK
A (BUILDING) No. of Floors No. - 3 OK
No. of Tenements No. - 3 OK
A (BUILDING) Number Of Lift(s) No. - 1 OK
Number Of Strature Lift(s) No. - - OK
Capacity Of Lift(s) Passanger No. - 6 OK
A (BUILDING) GROUND FLOOR PLAN - Lift - Width Mt. 1.70 3.00 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 3.20 OK
FIRST FLOOR PLAN - Lift - Width Mt. 1.70 3.00 OK
FIRST FLOOR PLAN - Lift - Depth Mt. 1.90 3.20 OK
SECOND FLOOR PLAN - Lift - Width Mt. 1.70 3.00 OK
SECOND FLOOR PLAN - Lift - Depth Mt. 1.90 3.20 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 3.00 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 3.20 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.500 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.125 OK
STAIRCASE - Riser No. On Flight No. - 12 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
Fire Escape Staircase - Flight Width Mt. 0.900 1.200 OK
Fire Escape Staircase - Tread Width Mt. 0.250 0.250 OK
Fire Escape Staircase - Riser Height Mt. 0.200 0.150 OK
Fire Escape Staircase - Riser No. On Flight No. 16 8 OK
Fire Escape Staircase - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.500 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.125 OK
STAIRCASE - Riser No. On Flight No. - 12 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
Fire Escape Staircase - Flight Width Mt. 0.900 1.200 OK
Fire Escape Staircase - Tread Width Mt. 0.250 0.250 OK
Fire Escape Staircase - Riser Height Mt. 0.200 0.176 OK
Fire Escape Staircase - Riser No. On Flight No. 16 16 OK
Fire Escape Staircase - Cabin Ht. Mt. - - - OK
SECOND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.500 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.125 OK
STAIRCASE - Riser No. On Flight No. - 12 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
Fire Escape Staircase - Flight Width Mt. 0.900 1.200 OK
Fire Escape Staircase - Tread Width Mt. 0.250 0.250 OK
Fire Escape Staircase - Riser Height Mt. 0.200 0.176 OK
Fire Escape Staircase - Riser No. On Flight No. 16 16 OK
Fire Escape Staircase - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.500 OK
STAIRCASE - Tread Width Mt. - - OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.000 OK
Fire Escape Staircase - Flight Width Mt. - 1.200 OK
Fire Escape Staircase - Tread Width Mt. - 0.250 OK
Fire Escape Staircase - Riser Height Mt. - - OK
Fire Escape Staircase - Riser No. On Flight No. 16 - OK
Fire Escape Staircase - Cabin Ht. Mt. - - 2.000 OK
RAIN WATER HARVESTING Area Sq.Mt. - - 16.92 OK
Width Mt. - - 2.90 OK
Depth Mt. - - 5.83 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 4.91 OK
Width Mt. - - 0.74 OK
Depth Mt. - - 6.61 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 12.94 OK
Width Mt. - - 3.15 OK
Depth Mt. - - 4.11 OK
Height Mt. - - - OK
A (BUILDING) Rain Water Harvesting - No No. 1 - 1 OK
Solar Water Heating System - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area The minimum size of plot for Nursing homes/Polyclinics/Hospital category shall be 300.0 sq.mt.{As per Rule No. 35.1, Table 7 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width The minimum size of plot for Nursing homes/Polyclinics/Hospital category shall be 300.0 sq.mt.{As per Rule No. 35.1, Table 7 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth The minimum size of plot for Nursing homes/Polyclinics/Hospital category shall be 300.0 sq.mt.{As per Rule No. 35.1, Table 7 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for Nursing homes/ Polyclinics/ Hospital category shall be 12.20 mt.{As per Rule No. 35.1, Table 7}
Plot Frontage The minimum size of plot for Nursing homes/Polyclinics/Hospital category shall be 300.0 sq.mt.{As per Rule No. 35.1, Table 7 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Non-highrise Commercial Building upto 16.4 mt. Ht. having Plot Depth 45 mt. or above and Plot width 15-21 mt., Margin required in Front shall be 8.0 mt., Rear 5.0 mt. and 2.5 mt. shall be provided on both side. {As per Rule No. 36 Table 10 & 11}
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Non-Residential Building, No Lift is reqd for Building upto G+2 floor {As per Rule No. 49.2.2}
Lift (1) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well shall not be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of the Fire Stair case shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. {As per Rule No. 43.5.3.6}
(4) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
(5) No Rule Defined
(6) ; No Rule Defined
(7) No Rule Defined
(8) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) No need to check distance from Building ENT.GATE
(4) -
(5) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) For Hospitals and Nursing Home type of Building, Provisions of Solar Water Heating System shall be done. Solar Water Heating System
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)