No Image Found   

Detail Scrutiny Report

Simdega Nagar Panchayat

Version Number: 1.0.66  
Version Date: 16/10/2020 
Report Generated On: 18-04-2023 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictSIMDEGA
AuthoritySIMDEGA NAGAR PANCHAYAT
Inward_NoSINPC/BP/0397/W02/2023
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageGotra
Taluka36
Architect Details
Architect Namevivek raj gupta
License No.SINPC/ENG/0001/2022
Architect AddressPRINCE CHOWK,SIMDEGA ,JHARKHAND
Architect EmailIDvivekgupta553@gmail.com
Architect Mobile No7008039097
Plot Details
Plot Use Medical
Plot SubUse Private Hospital
PlotNearbyReligiousStructure NA
Plot/SubPlot No4733,4684
NorthRoad Width - 3.6
SouthPlot No. - 4684
EastPlot No. - 4684
WestRoad Width - 15
Owner's Details
NameMAMTA KULLU
AddressHELENPUR,BHURU TOLI,SIMDEGA
Email IDbhanu.pratap.sahu11@gmail.com
Mobile No7677753897
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 951.44
2 Plot area as per Document by Applicant 951.44
3 Physical area measured at site 951.02
4 Area as per Site Visit (Site Visit Report) 951.44
5Area as per Drawing 951.44

Area of Plot Considered : 951.02

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
Plotplot
Plot OccupancyMedical
Plot SubUse Private Hospital
Building StructureNon-Highrise
Building TypeSpecial Building
Gross Plot Area 951.02
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 951.02
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 898.39
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 52.63
52.63
Balance Plot Area 898.39

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 570.61
Proposed Coverage Area ( 40.27 % ) 382.97
Total Prop. Coverage Area ( 40.27 % ) 382.97
Balance coverage area ( 19.73 % ) 187.64
FAR CHECK
Perm. FAR Area ( 2.000 ) 1902.04
Total Perm. FAR area 1902.04
Special FAR 1170.23
Proposed FAR Area 1170.23
Total Proposed FAR Area 1170.23
Consumed FAR (Factor) 1.23
Balance FAR Area 731.81
BUA CHECK
Total Proposed BuiltUp Area 1238.51


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 15 15.00
Proposed Road Width as per Master Plan 15 -
Road Widening Width 0 -
Plot size (as per measurement) 951.44 951.44
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 47.55 52.63 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 52.63 0.00 0.00 - 4.15 - 90.00 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 6 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (BUILDING) Medical Private Hospital Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (BUILDING) 30.00 9.00 9.00 9.00 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (BUILDING) Second Floor 2.75 - 3.00 2.75 - 2.85 2.40 - 2.43 OK
First Floor 2.75 - 3.00 2.75 - 2.85 2.40 - 2.43 OK
Ground Floor 2.75 - 3.00 2.75 - 2.85 2.40 - 2.43 OK
Plinth 0.45 - 0.60 - - 0.60 - - 0.60 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (BUILDING) Terrace Floor - - 1.00 - - 1.00 - - 1.00 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (BUILDING) - 3 - 3 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
570.61 382.97 OK
60% 40.27%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (BUILDING) - 382.97
  Total Prop. Coverage Area - 382.97
  Total Coverage Area 570.61 382.97

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
StairCase Lift Medical
A (BUILDING) 1 1238.51 49.08 19.20 1170.23 1170.23 1170.23 03
Grand Total : 1 1238.51 49.08 19.20 1170.23 1170.23 1170.23 03


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (BUILDING)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 399.33 382.97 399.33 382.97
First Floor 419.57 393.61 419.57 393.61
Second Floor 419.61 393.65 419.61 393.65
Terrace Floor 0.00 0.00 0.00 0.00
Total : 1238.51 1170.23 1238.51 1170.23


[-] UnitBUA Table for Building :A (BUILDING)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN FL 1 OTHER 327.92 327.39 12 1
FIRST FLOOR PLAN FL 2 OTHER 349.31 348.78 12 1
SECOND FLOOR PLAN FL 3 OTHER 349.33 349.18 9 1
Total: - - 1026.56 1025.35 33 3


[-] Building :A (BUILDING)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
StairCase Lift Medical
Ground Floor 399.33 16.36 0.00 382.97 382.97 382.97 01
First Floor 419.57 16.36 9.60 393.61 393.61 393.61 01
Second Floor 419.61 16.36 9.60 393.65 393.65 393.65 01
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 1238.51 49.08 19.20 1170.23 1170.23 1170.23 03
Total Number of Same Buildings : 1
Total : 1238.51 49.08 19.20 1170.23 1170.23 1170.23 03
[-] Table 4c-2

  FAR Area
Building FAR Area:1170.23
Existing FAR Area :0.00
Perm.
1902.04
Prop.
1170.23
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (BUILDING) 15 M WIDE MAIN ROAD 8.00 15.24 5.00 5.20 2.50 2.60 2.50 2.60 OK






[-] Inner Building Details (Table 6)
   
   
[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Number Of Strature Lift(s) Capacity Of Lift(s) Passanger Status
Prop Reqd Prop Reqd Prop Reqd Prop
A (BUILDING) 9.00 - 1 - 0 - 6 OK

[-] Lift Check Table

[-] For Building :A (BUILDING)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
GROUND FLOOR PLAN Lift 1.70 3.00 1.90 3.20 OK
FIRST FLOOR PLAN Lift 1.70 3.00 1.90 3.20 OK
SECOND FLOOR PLAN Lift 1.70 3.00 1.90 3.20 OK
TERRACE FLOOR PLAN Lift Machine Room 1.70 3.00 1.90 3.20 OK

   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car Visitors Car
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (BUILDING) Medical Private Hospital > 0 10 - 1 1 - - - -
> 0 10 - - - - - - -
Total : - - - - 1 4 - 0 3

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 4 51.00 OK
Total Car 1 12.50 4 51.00 OK
Visitor's Car Parking - - 3 38.25 OK
Total Visitor Parking - - 3 38.25 OK
Total 12.50 89.25 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

[-] Driveway Parking Checks (Table 7d)
Building/Plot Name Floor Name Driveway Name Width Status
Reqd Perm Prop
plot - DRIVE WAY 3.60 - 12.29 OK

   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (BUILDING)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.900 0.250 0.250 0.250 0.200 0.088 - 12 - - 0.000 Failed
Fire Escape Staircase 0.900 1.200 0.250 0.250 0.200 0.150 16 8 - - 0.000 OK
FIRST FLOOR PLAN STAIRCASE 0.900 0.250 0.250 0.250 0.200 0.088 - 12 - - 0.000 Failed
Fire Escape Staircase 0.900 1.200 0.250 0.250 0.200 0.176 16 16 - - 0.000 OK
SECOND FLOOR PLAN STAIRCASE 0.900 0.250 0.250 0.250 0.200 0.088 - 13 - - 0.000 Failed
Fire Escape Staircase 0.900 1.200 0.250 0.250 0.200 0.176 16 16 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.500 - 0.000 - 0.000 - 0 - - 2.000 OK
Fire Escape Staircase - 1.200 - 0.250 - 0.000 16 0 - - 2.000 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
RAIN WATER HARVESTING - - 16.92 - - 2.90 - - 5.83 - - 0.00 OK
ENT.GATE - - 4.91 - - 0.74 - - 6.61 - - 0.00 OK
SOLAR HEATING SYSTEM - - 12.94 - - 3.15 - - 4.11 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (BUILDING) Rain Water Harvesting 1 - 1 OK
Solar Water Heating System 1 - 1 OK
Entrance Gate 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (BUILDING)


[-] Floor:GROUND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:FIRST FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:SECOND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area 300.00 951.02 OK
  Plot Width - 20.27 OK
  Plot Depth - 46.94 OK
  Access Width 12.20 15.00 OK
  Plot Frontage - 20.27 OK
  Coverage Area 570.61 382.97 OK
  FAR Area
Bldg. FAR Area : 1170.23
Sanctioned FAR Area :0.00
1902.04 1170.23 OK





[-] Rules
Topic Rule
Plot Level
Plot Area The minimum size of plot for Nursing homes/Polyclinics/Hospital category shall be 300.0 sq.mt.{As per Rule No. 35.1, Table 7 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width The minimum size of plot for Nursing homes/Polyclinics/Hospital category shall be 300.0 sq.mt.{As per Rule No. 35.1, Table 7 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth The minimum size of plot for Nursing homes/Polyclinics/Hospital category shall be 300.0 sq.mt.{As per Rule No. 35.1, Table 7 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for Nursing homes/ Polyclinics/ Hospital category shall be 12.20 mt.{As per Rule No. 35.1, Table 7}
Plot Frontage The minimum size of plot for Nursing homes/Polyclinics/Hospital category shall be 300.0 sq.mt.{As per Rule No. 35.1, Table 7 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For SIMDEGA NAGAR PANCHAYAT, Max. 2.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Non-highrise Commercial Building upto 16.4 mt. Ht. having Plot Depth 45 mt. or above and Plot width 15-21 mt., Margin required in Front shall be 8.0 mt., Rear 5.0 mt. and 2.5 mt. shall be provided on both side. {As per Rule No. 36 Table 10 & 11}
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Non-Residential Building, No Lift is reqd for Building upto G+2 floor {As per Rule No. 49.2.2}
Lift (1) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well shall not be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of the Fire Stair case shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. {As per Rule No. 43.5.3.6}
(4) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
(5) No Rule Defined
(6) ; No Rule Defined
(7) No Rule Defined
(8) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) No need to check distance from Building ENT.GATE
(4) -
(5) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) For Hospitals and Nursing Home type of Building, Provisions of Solar Water Heating System shall be done. Solar Water Heating System
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)